Browse > Article
http://dx.doi.org/10.12813/kieae.2013.13.5.097

Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings  

Lhee, Sang Choon (Technology Development Team, Nepes ENC Inc.)
Choi, Young Joon (Technology Development Team, Nepes ENC Inc.)
Choi, Yool (Department of Medical Space Design & Management, Konyang University)
Publication Information
KIEAE Journal / v.13, no.5, 2013 , pp. 97-102 More about this Journal
Abstract
Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.
Keywords
Energy-efficient remodeling; Deteriorated high school building; Energy simulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Korea Research Institute of Eco-environmental Architecture, Korea Institute of Ecological Architecture ad Environment. A study on developing model and guide for energy-efficient remodeling at deteriorated k-12 school. Korea Energy Management Corporation. 2011.
2 Sang-Choon Lhee, Young-Joon Choi, Yool Choi. Determining the priority of factors for reducing energy at the deteriorated school buildings using AHP method, Journal of Korean Institute of Architectural Sustainable Environment and Building System. Vol. 11. No. 6. 2011. p. 127-132.
3 Ministry of Land, Infrastructure and Transport. Ways for promoting green remodeling to reduce energy at buildings, Press Release. 2013.07.24.
4 Korea Ministry of Government Legislation. Government legislation information center
5 Jin-Il Cho, Jong-Ho Yoon, U-Cheul Shin, Eun-Joo Kang, Hyeong-Ju Choi. A study on developing zero energy & ecological school model(II), Korea Educational Development Institute. 2009.
6 Korea Educational Development Institute. Yearbook of education statistics. 2010.
7 Tae-Woo Kim, Kang-Guk Lee, Won-Hwa Hong. A study on the energy source in school buildings with the changes of educational facilities standard, Journal of Korean Institute of Architectural Sustainable Environment and Building System. Vol. 10. No. 6. 2010. p. 73-80.