• Title/Summary/Keyword: Visible light curing

Search Result 55, Processing Time 0.024 seconds

THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS (가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구)

  • Kim, Sang-Bae;Lee, Kwang-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.180-188
    • /
    • 2002
  • Newly developed curing units(plasma arc curing units) operate at relatively high intensity and are claimed to result in optimum properties of composite resin in a short curing time. The purpose of this study was to evaluate the microhardness and microleakage at the resin-tooth interface of two types of composite resins polymerized with visible light and plasma arc curing units. The results from the present study can be summarized as follows 1. Microhardness in each depth was shown to be higher in group AHL than AP3 & AP6. Group ZHL was lower than AP6 at surface(p<0.05) and had no statistically significant difference at 1mm and 2mm(p>0.05). In other depths, group ZHL was higher than ZP3 and ZP6(p<0.05). 2. The incremental reduction in microhardness with depth was shown to be in all group except in surface-1mm of group AHL and $1{\sim}2mm$ of group ZHL(p<0.05). 3. Degree of microleakage in all oops were shown to be higher in gingival margin than occlusal margin but no statistically significant difference(p>0.05). 4. Differences between curing methods in microleakage were shown to be no statistically significant difference(p>0.05). 5. Differences between composite resins in microleakage were shown to be no statistically significant differ once(p>0.05).

  • PDF

A COMPARATIVE STUDY ON THE ANTICARIOGENECITY OF ENAMEL SURFACE ADJACENT TO GLASS IONOMER AND RESIN RESTORATION POLYMERIZED BY VISIBLE LIGHT AND ARGON LASER (가시광선과 아르곤 레이저에 의해 중합된 글라스 아이오노머와 레진 수복물 주변 법랑질의 항우식 효과에 관한 비교 연구)

  • Yoo, Byung-Kyu;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.62-75
    • /
    • 1998
  • The main purpose of this study was to compare the anticariogenecity of glass ionomer restorative material polymerized by argon laser versus visible light, The results from the present study can be summarized as follows; 1. Under the polarized light microscope, the specimens of laser-cured group showed the shallower lesion body than that of visible-light cured group, both in the stage of lesion initiation and progression. 2. Glass ionomer material cured by visible light showed shallower body of lesion than that of composite resin cured by argon laser at the stage of lesion progression(p<0.05). It was suggested fluoride released from the glass ionomer might have the additive anticariogenic effect. 3. Statistical difference between groups on depth of lesion body was evident after lesion progression (p<0.05). It was suggested that anticariogenic effect by argon laser was more effective at the stage of lesion progression than the lesion initiation. 4. The increment of lesion body during progression was highest in group IV (p<0.05). 5. Based upon the above-mentioned results of this study, it can be concluded that the advantage of anticariogenic effect and short curing time of argon laser in glass ionomer polymerization should be considered in children and adolescents whose caries activity is relatively higher.

  • PDF

Photopolymerization efficiency of dental resin composites with solid amine photoinitiators (고체 amine 광개시제에 따른 치과용 복합수지의 중합효율)

  • Sun, Gum-Ju
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Three t-amines, 4-(dimethylamino)benzoic acid (ABA), 4-(dimethylamino)benzaldehyde (MBA), 4-(dimethylamino)benzophenone (MBP), were investigated as new visible light photoinitiators for a dental resin composite of UDMA in order to improve photopolymerization effect. Three t-amines mixed with three photosensiizers, CQ, PD and DA, respectively. And the photopolymerization effect of photoinitiators were compared with that of 4-(dimethylamino)ethyl methacrylate (AEM), the most widely used photoinitiator. The photopolymerization efficiency of UDMA containing the photoinitiator increased with irradiation time. The increase was in the order: MBP

  • PDF

COMPARISON OF LINEAR POLYMERIZATION SHRINKAGE IN COMPOSITES AND COMPOMER POLYMERIZED BY PLASMA ARC OR CONVENTIONAL VISIBLE LIGHT CURING (리노미터를 이용한 할로겐 가시광선 광조사기와 플라즈마 아크 광조사기의 복합레진 및 컴포머의 광중합 양상 비교)

  • Lee, Jae-Ik;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.488-492
    • /
    • 2002
  • The purpose of this study was to evaluate the effectiveness of plasma arc curing (PAC) unit for composite and compomer curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit, the polymerization shrinkage rates and amounts of three composites (Z100, Z250, Synergy Duo Shade) and one compomer, that had been light cured by PAC unit or QTH unit, was compared using a custome made linometer. The measurement of polymerization shrinkage was peformed after polymerization with either QTH unit or PAC unit. In case of curing with the PAC unit, the composite was light cured with Apollo 95E for 6s, the power density of which was recorded as 1350 mW/$\textrm{cm}^2$ by Coltolux Light Meter. For light curing with QTH unit, the composite was light cured for 30s with the XL2500, the power density of which was recorded as 800 mW/$\textrm{cm}^2$ by Coltolux Light Meter. The amount of linear polymerization shrinkage was recorded in the computer every 0.5s for 60s. Ten measurements were made for each material. The amount of linear polymerization shrinkage for each material in 10s and 60s which were cured with PAC or QTH unit were compared with t test. The amount of polymerization shrinkage in the tested materials were compared with 1way ANOVA with Duncan's multiple range test. As for the amounts of polymerization shrinkage in 60s, there was no difference between PAC unit and QTH unit in Z250 and Synergy Duo Shade. In Z100 and Dyract AP, it was lower when it was cured with PAC unit than when it was cured with QTH unit (p<0.05). As for the amounts of polymerization shrinkage in 10s, there was no difference between PAC unit and QTH unit in Z100 and Dyract AP. The amounts of polymerization shrinkage was significantly higher when it was cured with PAC unit in Z250 and Synergy Duo Shade (p<0.05). The amounts of polymerization shrinkage in the tested materials when they were cured with QTH unit were Z250 (6.6um) < Z100 (9.3um), Dyract AP (9.7um) < Synergy Duo Shade (11.2um) (p<0.05). The amount of polymerization shrinkage when the materials were cured with PAC unit were Dyract AP (5.6um) < Z100 (8.1um), Z250(7.0um) < Synergy Duo Shade (11.2um) (p<0.05).

Modification of the curing characteristics of the photocurable resin FA1260T for 3D microfabrication using microstereolithography (삼차원 마이크로광조형 기술 응용을 위한 광경화 수지 EA1260T의 경화특성 조절에 대한 연구)

  • Kim Sung-Hoon;Jung Dae-Jun;Joo Jae-Young;Jeong Sung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.174-179
    • /
    • 2006
  • The curing characteristics of a photocurable resin are critical factors that often decide the ultimate resolution and structural sharpness of a final product fabricated by microstereolithography$(\mu-STL)$. In this study, we investigated the curing characteristics of the FA1260T photopolymer under a visible laser light of 42nm wavelength. Modification of the curing property of the FA1260T is attempted to reduce the cure depth $(D_c)$ by adding a radical quencher to the resin. Also, an organic solvent was used to reduce the resin viscosity for an improvement of the flatness of the liquid surface during layer-by-layer curing. As a result, the minimum $D_c$ has been reduced over a factor of 3 with no abrupt increase. Samples of three dimensional microstructures fabricated using the modified FA1260T are presented.

Phototoxic effect of blue light on the planktonic and biofilm state of anaerobic periodontal pathogens

  • Song, Hyun-Hwa;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok;Lee, Si-Young;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the phototoxic effects of blue light exposure on periodontal pathogens in both planktonic and biofilm cultures. Methods: Strains of Aggregatibacter actinomycetemcomitans, Fusobacterium nucleatum, and Porphyromonas gingivalis, in planktonic or biofilm states, were exposed to visible light at wavelengths of 400.520 nm. A quartz-tungsten-halogen lamp at a power density of $500mW/cm^2$ was used for the light source. Each sample was exposed to 15, 30, 60, 90, or 120 seconds of each bacterial strain in the planktonic or biofilm state. Confocal scanning laser microscopy (CSLM) was used to observe the distribution of live/dead bacterial cells in biofilms. After light exposure, the bacterial killing rates were calculated from colony forming unit (CFU) counts. Results: CLSM images that were obtained from biofilms showed a mixture of dead and live bacterial cells extending to a depth of $30-45{\mu}m$. Obvious differences in the live-to-dead bacterial cell ratio were found in P. gingivalis biofilm according to light exposure time. In the planktonic state, almost all bacteria were killed with 60 seconds of light exposure to F. nucleatum (99.1%) and with 15 seconds to P. gingivalis (100%). In the biofilm state, however, only the CFU of P. gingivalis demonstrated a decreasing tendency with increasing light exposure time, and there was a lower efficacy of phototoxicity to P. gingivalis as biofilm than in the planktonic state. Conclusions: Blue light exposure using a dental halogen curing unit is effective in reducing periodontal pathogens in the planktonic state. It is recommended that an adjunctive exogenous photosensitizer be used and that pathogens be exposed to visible light for clinical antimicrobial periodontal therapy.

Effect of Early Waterproof on Color Stability and Translucency Change of Glass-ionomer Cement (초기 방습이 글래스아이오노머 시멘트의 색안정성 및 투명도 변화에 미치는 영향)

  • Jeong, Seon-Wa;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.124-134
    • /
    • 1994
  • The shade of restorative materials is very important for successful restoration esthetically harmonized with the natural tooth. The purpose of this study was to evaluate the color stability and the opacity change of conventional chemical setting and visible light curing glass-ionomer cements for restorative esthetic filling. Specimens of each brand (GC Fuji II and Fuji II LC) were uniformly prepared and divided into three groups: In group l(control group), the specimens received no surface treatment; in group 2, the specimens were coated with varnish and the excess gently blown off; and in group 3. the specimens were coated with light-cured bonding resin and irradiated by a visible light curing unit for 20 seconds on both sides. All specimens were stored in distilled water at $37^{\circ}C$ and checked after for 24 hours. 2 months. 4 months, 6 months. and 8 months. The color characteristics($L^*,\;a^*,\;b^*$) and the opacity(Y%) of all the samples were measured by a spectrocolorimeter and the total color differences(${\Delta}E^*$) and opacity changes(${\Delta}Y%$) were computed. The following results were obtained : 1. The total tolor differences in all groups increased with time. 2. The total color differences of the LC groups after immersion for 8 months in distilled water at $37^{\circ}C$ were lower than those of GC groups(p<0.01), and the total color differences of the varnish or the light-cured bonding resin coated groups were lower than those of the control group with glass-ionomer cements which had no surface treatment(p<0.01). 3. In all groups the translucency decreased with time. 4. In the control group and the varnish coating group. the opacity changes of the GC groups were lower than those of the LC groups(p<0.01) and in the light-cured bonding resin coated group, there was no significant difference between the GC group and the LC group. 5. The opacity changes of the varnish or the light-cured bonding resin coated groups were lower than those of the control group(p<0.01). These results suggest that color change and opacity of conventional chemical setting and light cured glass-ionomer cement were increased with time, and the color changes and the opacity changes of a control group after immersion for 8 months in distilled water at $37^{\circ}C$ were greater than those of the varnish or the light-cured bonding resin coated groups.

  • PDF

Visible light-cured glycol chitosan hydrogel dressing containing endothelial growth factor and basic fibroblast growth factor accelerates wound healing in vivo

  • Yoo, Youngbum;Hyun, Hoon;Yoon, Sun-Jung;Kim, So Yeon;Lee, Deok-Won;Um, Sewook;Hong, Sung Ok;Yang, Dae Hyeok
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.365-372
    • /
    • 2018
  • Wounds that heal with excessive scar formation result in poor functional and aesthetic outcomes. To address this, in our study, visible light cured glycol chitosan (GCH) hydrogels containing endothelial growth factor (EGF) and basic fibroblast growth factor (bFGF) were prepared (GCH-EGF, GCH-FGF and GCH-EGF/FGF) and evaluated their efficacies on the improvement of wound healing in vivo. In vitro release test showed that the growth factors were released in a sustained manner along with initial burst for 24 h. In vitro cell proliferation assay of L-929 mouse fibroblast cell line resulted in the superior ability of GCH-EGF/FGF on the rate. In vivo results demonstrated that the growth factor loaded GCHs further enhanced wound healing compared with GCH. In particular, GCH-EGF/EFG showed the most remarkable wound healing effect among the samples.

EFFECT OF SURFACE DESIGN ON BOND STRENGTH OF RELINING DENTURE RESIN (결합면 형태가 이장용 레진의 결합강도에 미치는 영향)

  • Park Eun-Ju;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.167-174
    • /
    • 2004
  • Statement of problem: Removable partial denture and complete denture often require denture base relines to improve the fit against the tissue-bearing mucosa because of gradual changes in edentulous ridge contours and resorption of underlying bone structure. Purpose: This study was performed to investigate the effect of surface design on bond strength of relining denture base resins to denture base acrylic resin. Materials and method: Heat curing resin(Lucitone 199, Dentsply U.S.A. and Vertex, Dentimex, Holland), self curing resin(Tokuso rebase, Tokuyama, Japan), and visible light curing resin(Triad, Dentsply, U.S.A.) were used in this study. The surface designs were classified as butt, bevel and rabbet joint and the bond strengths were measured by Universial Testing Machine (Zwick 2020, Zwick Co., Germany). Results and Conclusion: The obtained results from this study were as follows ; 1. The bond strength of Vertex resin was higher than those of Tokuso rebase and Triad. 2. The bond strength of rabbet and bevel joint was higher than that of butt joint. 3. The failure mode of Triad and Tokuso rebase was mainly adhesive, but cohesive failure was shown mainly in vertex.

MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH (다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도)

  • Park, Soo-Man;Lee, Jae-Yong;Han, Seung-Ryul;Ha, Sang-Yoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.