• 제목/요약/키워드: Visible laser

검색결과 205건 처리시간 0.023초

아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합 (THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY)

  • 박성호;이창규
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF

양자기술용 가시광 및 근적외선 대역 고성능 파장 가변 레이저 기술 동향 (Trends in High-Performance Wavelength-Tunable Lasers for Quantum Technologies in Visible and Near-Infrared Bands)

  • 최병석;김성일;김현수;손정권;유종범;이동춘
    • 전자통신동향분석
    • /
    • 제39권5호
    • /
    • pp.61-73
    • /
    • 2024
  • Quantum information technology is driving innovative computing, communication, and sensing advancements. High-performance tunable lasers have become essential tools for precisely controlling and manipulating qubits. These lasers provide high stability and accuracy at specific wavelengths, enabling efficient control of various types of qubit systems, such as ions, neutral atoms, and defects. High-performance tunable lasers allow the initialization of qubit states, execution of quantum gate operations, and minimization of errors during the readout process. In addition, tunable lasers are critical in precisely regulating the interactions between multiple qubits to optimize quantum entanglement and correlation. This study explores the existing and state-of-the-art technologies related to the design and implementation of high-performance tunable lasers in the visible and near-infrared wavelength ranges that are crucial for key material systems used in quantum technology. Based on this investigation, we present new methodologies for maximizing the scalability of qubit control. These laser technologies are expected to contribute to the commercialization and performance enhancement of quantum information technology, a common foundational technology.

Nd:YAG 레이저 펄스에 따른 멸균효과 (Sterilization Effect by the Nd:YAG Laser pulse)

  • 정경환;정동경;박정규;최현우;서정민
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.695-703
    • /
    • 2020
  • 의료기술 발전으로 인해 의료기기 사용이 증가하는 추세이다. 의료기기 중 이식 및 치료를 위해 인체 내에 사용되는 경우가 많다. 그러므로 의료기관에서는 감염 예방을 위해 의료기기 형태와 재질에 따른 멸균법들이 다양하게 적용되고 있다. 뼈 이식에서 수산화인화석 재료가 가장 많이 보급되어 있다. 소형 의료기기에 알맞은 비전리방사선 중 고출력에너지를 가진 Q-switch Nd:YAG 레이저를 이용한 멸균법을 제시하고자 한다. 대장균과 충치균을 수산화인화석 디스크에 오염시켜, 출력1.5 W, 파장은 각각 자외선(266, 355 nm), 가시광선(532 nm), 적외선(1,064 nm), 1과 10 펄스를 각각 조사하였다, 본 연구에서 자외선 파장인 1.5 W, 266 nm, 10 pulse에서 멸균력을 가장 이상적으로 보여주었다. 다른 파장대인 적외선, 가시광선은 소극적 멸균력을 보였으며, 자외선 A와 자외선 C는 펄스에 따라 멸균 차이를 보였다. 레이저 멸균에서 파장 및 펄스에 따라 멸균 차이를 알 수 있었다.

옥소레이저 플라즈마에서 발생된 연 X-선을 이용한 밀착현미경기술 (Contact Microscopy by Using Soft X-ray Radiation from Iodine Laser Produced Plasma)

  • 최병일;김동환;공홍진;이상수
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.46-51
    • /
    • 1990
  • Soft X-ray는 자연상태의 생물체를 높은 대비(high contrast)의 영상으로 관찰할 수 있는 광원이다. 1GW급의 광분해 옥소레이저 ($\lambda$=1.315$\mu\textrm{m}$, E=12.7J)를 몰리브덴(Mo) 표적에 집속시켜 플라즈마를 발생시켰으며 플라즈마에서 방출되는 넓은 파장 영역의 연속스펙트럼을 0.1$\mu\textrm{m}$ 두께의 알루미늄 필터를 거치게 하여 soft X-ray 영역에 중심세기를 갖는 광원을 얻었다. X-ray용 resist로 감도가 좋은 PBS를 사용하여 그물망(mesh), 거미줄, 적혈구의 replica를 얻었다. 본해능에 미치는 두 가지의 주된 영향인 광원의 크기에 의한 영향과 Fresnel 회절효과를 고찰하고 실험결과를 비교하였다. 본 실험에서는 0.1$\mu\textrm{m}$이하의 분해능을 얻었다.

  • PDF

Comparative evaluation of photobiomodulation therapy at 660 and 810 nm wavelengths on the soft tissue local anesthesia reversal in pediatric dentistry: an in-vivo study

  • Ankita Annu;Sujatha Paranna;Anil T. Patil;Sandhyarani B.;Adhithi Prakash;Renuka Rajesh Bhurke
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권4호
    • /
    • pp.229-236
    • /
    • 2023
  • Background: Local anesthesia has been reliably used to control pain during dental procedures and is important in pediatric dentistry. However, children occasionally complain of prolonged numbness after dental treatment, leading to several problems. Studies conducted to reverse the effect of local anesthesia using phentolamine mesylate and photobiomodulation therapy (PBM) are encouraging but limited. PBM is a type of light therapy that utilizes visible and near-infrared non-ionizing electromagnetic spectral light sources. Hence, this study used this modality to compare the reversal of local anesthesia at two different wavelengths. This study compared the effect of PBM at 660 and 810 nm wavelengths on the reversal of soft tissue local anesthesia using a diode LASER in pediatric dentistry. Method: Informed consent and assent were obtained, and the participants were then divided randomly into three groups of 20 children each: control group-without LASER irradiation, LASER irradiation at 660 nm, and LASER irradiation at 810 nm. Sixty children aged 4-8 years with deciduous mandibular molars indicated for pulp therapy were administered an inferior alveolar nerve block. After 45 min of injection, a duration that was similar to the approximate duration of treatment, they were exposed to 660- and 810-nm LASER irradiation according to their groups until reversal of local anesthesia was achieved. The control group did not undergo LASER irradiation. The reversal of the soft tissue local anesthetic effect was evaluated using palpation and pin prick tests every 15 min, and the LASER irradiation cycle continued until reversal of the soft tissue local anesthesia was achieved. Results: A significant reduction of 55.5 min (27.6%) in the mean soft tissue local anesthesia reversal time was observed after the application of 810 nm wavelength PBM and 69 min (34.7%) after 660 nm wavelength LASER irradiation. Conclusion: PBM with a 660 nm wavelength was more effective in reducing the mean soft tissue local anesthesia reversal duration, and thus can be used as a reversal agent for soft tissue local anesthesia in pediatric dentistry.

평판 경계층 확산화염에서의 국부적 가속현상에 관한 실험적 연구 (An experimental study on the local velocity acceleration in a flat plate boundary layer diffusion flame)

  • 심성훈;하지수;신현동
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.847-864
    • /
    • 1988
  • 본 연구에서는 연료분출에 박리가 있는 경우와 없는 경우 각각에 대하여 화염 대 근처의 국부가속 현상이 박리에 의하여 어떻게 영향을 받는가를 실험적으로 규명하 고, 나아가서 종래에 행해져 왔던 관련 연구 결과를 재검토할려고 한다.

Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing

  • Seong-keun, Yoo;Ye-Hyeon, Jo;In-Sung Luke, Yeo;Hyung-In, Yoon;Jae-Hyun, Lee;Jin-Soo, Ahn;Jung-Suk, Han
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.335-345
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence.

기판 온도의 영향에 따른 펄스레이저 증착법으로 성장된 ZnO 박막의 발광 특성 (Effect of Substrate Temperature on the Emission Characteristics of ZnO Films Grown by Pulsed Laser Deposition)

  • 김영환;김성일
    • 한국진공학회지
    • /
    • 제18권5호
    • /
    • pp.358-364
    • /
    • 2009
  • 펄스레이저 증착법으로 박막의 결함 생성을 최소화하여 우수한 발광 특성을 가지는 ZnO 박막 성장에 대한 연구를 수행하였다. 이를 위하여 기판 온도를 $400^{\circ}C$에서 $850^{\circ}C$까지 변화시켜 박막을 증착한 후 엑스선 회절법, 원자힘 현미경, photoluminescence (PL) 등을 사용하여 박막의 특성 변화를 분석하였다. 그 결과 ZnO 박막은 기판 온도에 관계없이 (0001) 사파이어 기판에 c-축 배향성을 가지며 성장하였음을 확인하였고 기판온도 $600^{\circ}C$에서 가장 조밀한 박막이 형성되면서 박막에 응력이 거의 걸리지 않고 결정성도 우수함을 확인하였다. PL 분석 결과 역시 $600^{\circ}C$에서 증착된 ZnO 박막이 UV 발광 피크의 반치폭 및 결함에 의한 가시영역에서의 발광 등을 고려했을 때 가장 뛰어난 특성을 보여주었다. 이와 같은 결과는 ZnO 박막의 발광 특성이 박막의 구조적 특성과 매우 밀접한 관계가 있음을 나타내며 또한 기판 온도가 매우 중요한 역할을 함을 나타낸다. 결론적으로 기판 온도 $600^{\circ}C$에서 우수한 UV 발광 특성을 가지면서 결함에 의한 가시영역 발광이 거의 나타나지 않는 ZnO 박막을 성장시킬 수 있었고 이러한 박막은 UV 광소자에 응용될 수 있을 것으로 생각된다.

레이저 반사광을 이용한 미세 표면 거칠기 측정 알고리즘에 관한 연구 (Study on Algorithm of Micro Surface Roughness Measurement Using Laser Reflectance Light)

  • 최규종;김화영;안중환
    • 대한기계학회논문집A
    • /
    • 제32권4호
    • /
    • pp.347-353
    • /
    • 2008
  • Reflected light can be decomposed into specular and diffuse components according to the light reflectance theory and experiments. The specular component appears in smooth surfaces mainly, while the diffuse one is visible in rough surfaces mostly. Therefore, each component can be used in forming their correlations to a surface roughness. However, they cannot represent the whole surface roughness seamlessly, because each formulation is merely validated in their available surface roughness regions. To solve this problem, new approaches to properly blend two light components in all regions are proposed in this paper. First is the weighting function method that a blending zone and rate can be flexibly adjusted, and second is the neural network method based on the learning from the measurement data. Simulations based on the light reflectance theory were conducted to examine its performance, and then experiments conducted to prove the enhancement of the measurement accuracy and reliability through the whole surface roughness regions.

Nd:YAG-PLD법에 의해 제작된 ZnO:AI 박막의 구조적, 광학적, 전기적 특성 (Structural, Optical and Electrical Properties of AI Doped ZnO Thin Films Prepared by Nd:YAG-PLD Technology)

  • 노임준;임재성;이천;신백균
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1596-1601
    • /
    • 2007
  • Aluminum doped zinc oxide (AZO) thin films were deposited on coming glass substrates using an Nd:YAG pulsed laser deposition technology. The AZO thin films were deposited with various growth conditions such as the substrate temperature and oxygen partial pressure. In this work, we used various measurement technologies in order to investigate the electrical, structural, and optical properties of the AZO thin films. Among the AZO thin films, the one prepared at the substrate temperature of $300^{\circ}C$ and oxygen partial pressure of 5 mTorr showed the best properties of an electrical resistivity of $4.63{\times}10^{-4}{\Omega}{\cdot}cm$, a carrier concentration of $9.25{\times}10^{20}cm^{-3}$, and a carrier mobility of $31.33cm^2/V{\cdot}s$. All the AZO thin films showed an high average optical transmittance over 90 % in visible region.