• Title/Summary/Keyword: Visible Korean Human

Search Result 201, Processing Time 0.025 seconds

A STUDY ON THE ACCURACY OF THE ROOT-ZX ACCORDING TO THE VARIOUS CONDITIONS OF ROOT CANALS (근관내 여러 가지 조건에 따른 Root-ZX의 정확도에 관한 연구)

  • Hwang, Ho-Keel;Shin, Young-Guen;Kim, Pyung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.474-482
    • /
    • 2000
  • Currently frequency-dependent type electronic apex locators have been widely used to determine the working length in endodontic treatment. But, accuracy of electronic apex locators is controversial. The purpose of this study was to evaluate the accuracy of Root-ZX(Morita Co., Japan) at different kinds of conditions of root canals compared with the radiographic working length. The 40 extracted human anterior teeth with fully formed apices and without any caries were used. The radiographs were taken for working length with the 0.5mm short of #15 K-file tip just visible at the foramen under the surgical microscope(Carl Zeiss Co. Germany) at 25X. Then the electronic working lengths were determined with Root-ZX at the different kinds of conditions of root canals according to the presence of electrolyte and Crown-down pressureless technique. The results were as follows ; 1. There was no significant statistical difference in working length between radiograph and Root-ZX. 2. There was no significant statistical difference in electronic working length between the canal with electrolyte and without electrolyte. 3. There was no significant statistical difference in electronic working length between the canal without any instrumentation and after Crown-dow pressureless technique. 4. Of the total 40 root canals, 85% in Group I, 92.5% in Group II, 95% in Group III and 95% in Group IV using Root-ZX showed coincidence within 0.5mm accuracy compaing with the radiographic working length. The results showed that the Root-ZX can be use effectively for measuring the working length of root canal after instrumentation with Crown-down pressureless technique regardless of the presence of electrolyte in root canal.

  • PDF

The LLLT effect of visible and IR light LEDs in short distance (근거리에서 가시광과 적외광 LED의 LLLT (low level light therapy) 효과)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.283-285
    • /
    • 2013
  • 피부의 관리를 위한 방법 중 광을 이용한 케어는 비침습적인 방법으로 세포를 활성화 시켜 도움을 주는 매우 유용한 방법이다. 최근에는 낮은 에너지의 LED를 광원으로 이용하는 LLLT (Low Level Light Therapy)가 많이 적용이 된다. 본 논문에서는 피부 미용기기에서 많이 사용되고 있는 가시광 영역의 적색과 황색, 그리고 적외선 영역의 LED를 이용하여 array를 제작하였다. 제작된 LED array는 5V의 전압과 50mA의 전류로 구동되며, 적색이 평균 $10.7mW/cm^2$, 황색이 평균 $1.8mW/cm^2$, 적외선이 평균 $5.5mW/cm^2$의 광출력을 갖는다. 이를 배양된 human cell plate에 각각 10, 20, 40분의 시간으로 조사하였으며, LED array와 조사면 사이에 20 mm의 거리를 두어 균일한 광량이 조사 될 수 있도록 하였다. 실험결과, wound healing의 경우는 적색광을 조사하였을 때, injury line의 길이가 $604.36{\mu}m$에서 10분 조사 시 $368.92{\mu}m$, 20분 조사 시 $298.04{\mu}m$, 40분 조사 시 $491.22{\mu}m$로 줄어드는 효과를 보였으며 특히 20분간 조사하였을 경우의 효과가 가장 좋았다. Cell regeneration의 경우는 황색광을 20분간 조사하였을 경우에 UV 에 의해 손상된 세포 수가 가장 크게 줄어드는 것을 확인할 수 있었다. 결과적으로 photorejuvenation 효과를 줄 수 있는 wound healing과 cell regeneration에는 적색 및 황색광의 LED array를 20분간 조사하였을 때가 가장 효과적이었으며, 적외광의 경우에는 모든 실험에서 효과가 없음을 확인할 수 있었다.

  • PDF

SAR Remote Sensing Technology Development and Application in China

  • Jing, Li
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.448-453
    • /
    • 2002
  • Remote sensing technology is one of the most powerful tools for human to know the nature and their living environment. However, before microwave remote sensing was developed and applied, remote sensing application was limited strongly by weather and time. Microwave remote sensing technology solves the problem. It makes us to have the capability to acquire information at all time of the day and under all weather condition, and make remote sensing technology be used in more wider area. Microwave remote sensing system include mainly Synthetic Aperture Radar (SAR), Microwave Radiometer, Microwave Scatterometer, and Altimeter (ALT). As SAR can acquire image whose spatial resolution is similar with visible and infrared image, it is paying much attention to and playing a more and more important role in earth observation. In recent year, the development of new SAR technology (multi-band and multi-polarization technology, InSAR technology, D-InSAR technology, and so on) makes SAR remote sensing go to an new stage, and its application area become more and more widely. The first Synthetic Aperture Radar (SAR) in the world appeared in 1960. After that, SAR and its application all developed very fast. Some radar satellites launched and run (include Seasat-A in 1978, ERS-1 in 1991, JERS-1 in 1992, Radarsat in 1995, and so on) promote SAR research and application in world greatly. China began to develop its SAR sensor and research SAR application in 1970s. After more than 30 years' research, it get some important development in sensor development data processing method, and application. Some operational systems have been used and play an important role. This paper will introduce the development of SAR technology and its application in China.

  • PDF

Improvement of Land Cover / Land Use Classification by Combination of Optical and Microwave Remote Sensing Data

  • Duong, Nguyen Dinh
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.426-428
    • /
    • 2003
  • Optical and microwave remote sensing data have been widely used in land cover and land use classification. Thanks to the spectral absorption characteristics of ground object in visible and near infrared region, optical data enables to extract different land cover types according to their material composition like water body, vegetation cover or bare land. On the other hand, microwave sensor receives backscatter radiance which contains information on surface roughness, object density and their 3-D structure that are very important complementary information to interpret land use and land cover. Separate use of these data have brought many successful results in practice. However, the accuracy of the land use / land cover established by this methodology still has some problems. One of the way to improve accuracy of the land use / land cover classification is just combination of both optical and microwave data in analysis. In this paper for the research, the author used LANDSAT TM scene 127/45 acquired on October 21, 1992, JERS-1 SAR scene 119/265 acquired on October 27, 1992 and aerial photographs taken on October 21, 1992. The study area has been selected in Hanoi City and surrounding area, Vietnam. This is a flat agricultural area with various land use types as water rice, secondary crops like maize, cassava, vegetables cultivation as cucumber, tomato etc. mixed with human settlement and some manufacture facilities as brick and ceramic factories. The use of only optical or microwave data could result in misclassification among some land use features as settlement and vegetables cultivation using frame stages. By combination of multitemporal JERS-1 SAR and TM data these errors have been eliminated so that accuracy of the final land use / land cover map has been improved. The paper describes a methodology for data combination and presents results achieved by the proposed approach.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF INTERNAL DISCOLORATION OF TEETH BY ENDODONTIC SEALERS (수종(數種) 근관(根管) 충전재(充塡材)에 의(依)한 치아(齒牙) 내부(內部) 변색효과(變色效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Geol, Kim-In;Cho, Jae-O
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.65-72
    • /
    • 1987
  • The purpose of this study was to examine the influence of several root canal sealers on the discoloration of internal surface after root canal obstruction. Twenty four sound human premolars, extracted for orthodontic or prosthodontic purposes, were randomly selected and divided into eight groups. Extracted premolars were prepared, and the following seven materials were introduced into the pulp cavities: AH 26, Fuji ionomer (Type I) cement, N2, Oxypara "Murakami", Kerr sealer, PCA sealer, and G-C's Propac ZOE cement. After 7 weeks of incubation; the discolored tooth crowns were hemisectioned, and the internal staining patterns were examined. Then, with an association of observed values the mean intensity scores and percentage of coverage scores of the internal staining patterns in teeth attained by two observers using for Chisquare test were analyzed. The results were as follows: 1. All the experimental premolar's crown showed various ranged discoloration of internal surface. 2. There was no significance between the association scores of two observers participated into this experiments:% coverage scores (P > 0.05) and intensity (P > 0.05) 3. The crowns filled with PCA sealer, AH 26, and Fuji ionomer cement was visible within a depth of one third of dentin. (P> 0.05) 4. For N2, Kerr sealer, and G-C's Propac cement, A slight dentinal staining was recorded, which penetrated up to half way into the dentin. (P> 0.05) 5. It was noticed that the teeth filled with Oxypara "Murakami" were discolored more than two thirds of the dentinal layer. 6. On the control group, there was no discoloration.

  • PDF

A STUDY ON THE DENTIN BONDING OF ONE-STEP BONDING AGENT (ONE-STEP 접착제의 상아질 접착에 관한 연구)

  • Cho, Young-Gon;Park, Sung-Taek;Park, Kwang-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.468-476
    • /
    • 1998
  • The purpose of this study was to observe the morphologic change of dentinal surface, adhesion in interface between dentin and bonding agents, and penetration pattern of resin tags into dentinal tubles according to bonding procedure of ONE-STEP universal adhesive system. Ten extracted human molars were mounted in dental stone and sectioned to expose mid-coronal occlusal dentin and again sectioned tooth crown apically. Specimens were randomly assigned to three groups for dentin conditioning with 32% phoshoric acid, two coats of bonding agents after dentin conditioning, and bond of composite resin. The surfaces of dentin were treated with etch ant and applied bonding agent, and bonded composite resin according to the directions of manufacturer. Specimens which were boned composite were sectioned longitudinally for observing interfaces between resin and dentin. Two of specimens which were sectioned longitudinally were immersed in 6 N HCL for 30 seconds and 1% NaOCL for 12 hours to partially demineralize and deproteinize the dentin substrate. Each specimen was mounted on a brass stub, sputter-coated with gold and observed under SEM. The result were as follows : 1. On the dentinal surface which was conditioned with 32% phosphoric acid. the smear layer was completely removed. orifices of dentinal tubules were opened 3-$5{\mu}m$ wide. and dentinal surface was irregular. 2. On the dentinal surface which was applied ONE-STEP. bonding agent. resin particles were observed on the orifices of dentinal tubules and intertubular dentin. 3. There were close adaptation between dentin and resin and were the pattern which composite invaded into dentin. 4. 1-$3{\mu}m$-wide hybrid layer was visible in the interface between dentin and resin. 5. Long and funnel shaped resin tags were observed in demineralized specimens. and the surfaces of tags were rough.

  • PDF

AN IN VITRO EVALUATION OF THE ACCURACY OF ROOT ZX ELECTRONIC APEX LOCATOR (전자근관장측정기 Root ZX의 정확도에 관한 실험적 연구)

  • Kang, Dae-Hoon;Chung, Kwang-Hee;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.339-345
    • /
    • 1998
  • The purpose of this study was to evaluate the in vitro accuracy of Root ZX(Morita Co., Japan) which is the ratio type electronic apex locator. The 86 extracted human palatal roots of maxillary molar with fully formed apices were used. File lengths with the file tip just visible at the foramen were compared to those measured with Root ZX. For length measuring with Root ZX, saline test model with which the apical 1/3 of each root was submerged into normal saline were designed. The root canal lengths were determined with Root ZX and the radiographs were taken with a file in the canal. The distances from file tips of Root ZX lengths to apecies in radiographs also were measured with Profile projector PJ311(Mitutoyo Co., Japan). The results were as follows : 1. The root canal length determined with electronic apex locator was $0.78{\pm}0.53mm$ shorter than the length with visual measurement. 2. The file tip of Root ZX lengths was located at $0.85{\pm}0.49mm$ away from the apex in radiograph. 3. The accuracy of the Root ZX was 79.1% within 0.5mm of visual working length and 96.5% within 1.0mm.

  • PDF

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Gold Nanoparticles Conjugation Enhances Antiacanthamoebic Properties of Nystatin, Fluconazole and Amphotericin B

  • Anwar, Ayaz;Siddiqui, Ruqaiyyah;Shah, Muhammad Raza;Khan, Naveed Ahmed
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.171-177
    • /
    • 2019
  • Parasitic infections have remained a significant burden on human and animal health. In part, this is due to lack of clinically-approved, novel antimicrobials and a lack of interest by the pharmaceutical industry. An alternative approach is to modify existing clinically-approved drugs for efficient delivery formulations to ensure minimum inhibitory concentration is achieved at the target site. Nanotechnology offers the potential to enhance the therapeutic efficacy of drugs through modification of nanoparticles with ligands. Amphotericin B, nystatin, and fluconazole are clinically available drugs in the treatment of amoebal and fungal infections. These drugs were conjugated with gold nanoparticles. To characterize these gold-conjugated drug, atomic force microscopy, ultraviolet-visible spectrophotometry and Fourier transform infrared spectroscopy were performed. These drugs and their gold nanoconjugates were examined for antimicrobial activity against the protist pathogen, Acanthamoeba castellanii of the T4 genotype. Moreover, host cell cytotoxicity assays were accomplished. Cytotoxicity of these drugs and drug-conjugated gold nanoparticles was also determined by lactate dehydrogenase assay. Gold nanoparticles conjugation resulted in enhanced bioactivity of all three drugs with amphotericin B producing the most significant effects against Acanthamoeba castellanii (p < 0.05). In contrast, bare gold nanoparticles did not exhibit antimicrobial potency. Furthermore, amoebae treated with drugs-conjugated gold nanoparticles showed reduced cytotoxicity against HeLa cells. In this report, we demonstrated the use of nanotechnology to modify existing clinically-approved drugs and enhance their efficacy against pathogenic amoebae. Given the lack of development of novel drugs, this is a viable approach in the treatment of neglected diseases.

Syringaresinol derived from Panax ginseng berry attenuates oxidative stress-induced skin aging via autophagy

  • Choi, Wooram;Kim, Hyun Soo;Park, Sang Hee;Kim, Donghyun;Hong, Yong Deog;Kim, Ji Hye;Cho, Jae Youl
    • Journal of Ginseng Research
    • /
    • v.46 no.4
    • /
    • pp.536-542
    • /
    • 2022
  • Background: In aged skin, reactive oxygen species (ROS) induces degradation of the extracellular matrix (ECM), leading to visible aging signs. Collagens in the ECM are cleaved by matrix metalloproteinases (MMPs). Syringaresinol (SYR), isolated from Panax ginseng berry, has various physiological activities, including anti-inflammatory action. However, the anti-aging effects of SYR via antioxidant and autophagy regulation have not been elucidated. Methods: The preventive effect of SYR on skin aging was investigated in human HaCaT keratinocytes in the presence of H2O2, and the keratinocyte cells were treated with SYR (0-200 ㎍/mL). mRNA and protein levels of MMP-2 and -9 were determined by real-time PCR and Western blotting, respectively. Radical scavenging activity was researched by 2,2 diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) assays. LC3B level was assessed by Western blotting and confocal microscopy. Results: SYR significantly reduced gene expression and protein levels of MMP-9 and -2 in both H2O2-treated and untreated HaCaT cells. SYR did not show cytotoxicity to HaCaT cells. SYR exhibited DPPH and ABTS radical scavenging activities with an EC50 value of 10.77 and 10.35 ㎍/mL, respectively. SYR elevated total levels of endogenous and exogenous LC3B in H2O2-stimulated HaCaT cells. 3-Methyladenine (3-MA), an autophagy inhibitor, counteracted the inhibitory effect of SYR on MMP-2 expression. Conclusion: SYR showed antioxidant activity and up-regulated autophagy activity in H2O2-stimulated HaCaT cells, lowering the expression of MMP-2 and MMP-9 associated with skin aging. Our results suggest that SYR has potential value as a cosmetic additive for prevention of skin aging.