• Title/Summary/Keyword: Visibility evaluation

Search Result 220, Processing Time 0.026 seconds

Affordance Elements According to the Usability of the Interface of Immersive Virtual Reality Clinical Skill Content (몰입형 가상현실 의료 술기 콘텐츠의 인터페이스 사용성에 따른 어포던스 하위 평가 요소에 관한 연구)

  • Hwang, Hyo-Hyon;Choi, Yoo-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.6
    • /
    • pp.307-318
    • /
    • 2022
  • Virtual reality is actively used in the medical field as a learning effectiveness that induces immersion, but research on the factors that induce learning immersion is insufficient. Therefore, this study extracted the usability and cognitive affordance evaluation elements of the interface through literature research and selected four types of virtual reality medical contents to conduct a Useability-Test for experts. Based on this, an interface design method according to virtual reality medical technology content was proposed. In summary, it can be seen that the information-providing interface affects immersion due to visibility, distance from the experience's gaze, color harmony, uniform visualization, feedback, reaction speed, and expected changes resulting from manipulation, and does not impair immersion. This study has limitations in generalization using limited content, so it is expected that continuous research will discuss the development of standardized guides in interface design and the precision of interface design research from a user perspective.

Comparison of GAN Deep Learning Methods for Underwater Optical Image Enhancement

  • Kim, Hong-Gi;Seo, Jung-Min;Kim, Soo Mee
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.32-40
    • /
    • 2022
  • Underwater optical images face various limitations that degrade the image quality compared with optical images taken in our atmosphere. Attenuation according to the wavelength of light and reflection by very small floating objects cause low contrast, blurry clarity, and color degradation in underwater images. We constructed an image data of the Korean sea and enhanced it by learning the characteristics of underwater images using the deep learning techniques of CycleGAN (cycle-consistent adversarial network), UGAN (underwater GAN), FUnIE-GAN (fast underwater image enhancement GAN). In addition, the underwater optical image was enhanced using the image processing technique of Image Fusion. For a quantitative performance comparison, UIQM (underwater image quality measure), which evaluates the performance of the enhancement in terms of colorfulness, sharpness, and contrast, and UCIQE (underwater color image quality evaluation), which evaluates the performance in terms of chroma, luminance, and saturation were calculated. For 100 underwater images taken in Korean seas, the average UIQMs of CycleGAN, UGAN, and FUnIE-GAN were 3.91, 3.42, and 2.66, respectively, and the average UCIQEs were measured to be 29.9, 26.77, and 22.88, respectively. The average UIQM and UCIQE of Image Fusion were 3.63 and 23.59, respectively. CycleGAN and UGAN qualitatively and quantitatively improved the image quality in various underwater environments, and FUnIE-GAN had performance differences depending on the underwater environment. Image Fusion showed good performance in terms of color correction and sharpness enhancement. It is expected that this method can be used for monitoring underwater works and the autonomous operation of unmanned vehicles by improving the visibility of underwater situations more accurately.

Structural Relationship and Evaluation Factors in Financial Platform Business (금융권 플랫폼 비즈니스의 서비스 품질 요인간 구조적 관계에 대한 연구)

  • Hoon Huh
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.198-208
    • /
    • 2023
  • In order to enhance competitiveness in the industry, financial companies are building a high level of customer satisfaction and repurchase intention by further strengthening not only the technical quality of the platform business but also the customer-oriented service quality. Theoretically, it is time for a theoretical review of whether the expansion of service quality using platform business in the financial industry is directly linked to the performance of financial companies, such as satisfaction and repurchase intention of existing customers. Based on the rapid growth of mobile and the main activities of financial platform companies above, This study attempted to test a significant impact on customer satisfaction and reuse intention on information services and system services, which are service quality of mobile financial platforms. Even if a number of financial companies compete with each other, they could survive by dividing the market, In the digital environment, customers have free access, so the winner can monopolize the market. It is an environment in which customers can move to platform companies that provide better services. The contents presented through the results in this study will be able to be used strategically in terms of the implementation and operation of the financial platform. In addition, it served as an opportunity to find independent variables that affect customer satisfaction and reuse intention, which are financial platform service quality, and suggested the possibility of continuous development of the platform in the future. In summary, the service quality of financial platforms can further expand users by emphasizing user visibility in terms of information services and utilizing user-centered financial platforms that increase customer satisfaction and reliability by strengthening the responsiveness and ease of system services. This study is of important value and is believed to have laid an important foundation for future research.

Safety and Pitfalls of Blepharoptosis Surgery in Elderly People

  • Yuji Shirakawa;Kazuhisa Uemura;Shinji Kumegawa;Kazuki Ueno;Hiroki Iwanishi;Shizuya Saika;Shinichi Asamura
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.446-451
    • /
    • 2023
  • Background Elderly patients often have complications of blepharoptosis surgery that can result in the appearance or exacerbation of superficial punctate keratopathy (SPK). However, postoperative changes to SPK status have not been previously reported. We used subjective assessment of symptoms and measurement of SPK scale classification to investigate the safety and efficacy of blepharoptosis surgery in elderly patients. Methods Included in this prospective study were 22 patients (44 eyes) with bilateral blepharoptosis that underwent surgery. Patients comprised 8 males and 14 females with a mean (±standard deviation) age of 75.7 ± 8.2 years (range: 61-89). Blepharoptosis surgery consisted of transcutaneous levator advancement and blepharoplasty including resection of soft tissue (skin, subcutaneous tissue, and the orbicularis oculi muscle). Margin reflex distance-1 (MRD-1) measurement, a questionnaire survey of symptoms and SPK scale classification, was administered preoperatively and 3 months postoperatively for evaluation. Results The median MRD-1 was 1 mm preoperatively and 2.5 mm postoperatively, representing a significant postoperative improvement. SPK area and density scores were found to increase when the MRD-1 increase was more than 2.5 mm with surgery. All 10 items on the questionnaire tended have increased scores after surgery, and significant differences were observed in 7 items (poor visibility, ocular fatigue, heavy eyelid, foreign body sensation, difficulty in focusing, headaches, and stiff shoulders). Conclusion Blepharoptosis surgery was found to be a safe and effective way to maintain the increase in MRD-1 within 2.0 mm. Despite the benefits, surgeons must nonetheless be aware that blepharoptosis surgery is a delicate procedure in elderly people.

Manufacturing and Characteristic Evaluation of Free space Optical Communication Devices in 5G Mobile Base Stations for Emergency Disaster Response (긴급재난 대응용 5G 이동 기지국을 위한 대기공간 광통신 장치의 제작과 특성평가)

  • Jin-Hyeon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.131-138
    • /
    • 2023
  • In this paper, a free space optical communication device that can be used in a mobile base station of several km or less was fabricated and its characteristics were investigated. To overcome the loss due to atmospheric transmission, an optical fiber amplifier (EDFA) with an output of 23 dBm or more was used. In order to increase the focusing speed and miniaturization of the laser beam, an optical lens was manufactured, and a transmission lens was designed to have beam divergence within the range of 1.5 to 1.8 [mrad]. A PT module that controls PAN/TILT was fabricated in order to reduce pointing errors and effective automatic alignment between transceiver devices. In this study, Reed-Solomon (RS) code was used to maintain the transmission quality above a certain level. It was manufactured to be able to communicate at a wireless distance of 300m in a weather situation with visibility of 300m. For performance measurement, it was measured using BERT and eye pattern analyzer, and it was confirmed that BER can be maintained at 2.5Gbps.

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts

  • Bo Ra Kwon;Jung Min Chang;Soo Yeon Kim;Su Hyun Lee;Soo-Yeon Kim;So Min Lee;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.25-32
    • /
    • 2020
  • Objective: To comparatively evaluate the scan coverage and diagnostic performance of the two-view scan technique (2-VST) of the automated breast ultrasound system (ABUS) versus the conventional three-view scan technique (3-VST) in women with small breasts. Materials and Methods: Between March 2016 and May 2017, 136 asymptomatic women with small breasts (bra cup size A) suitable for 2-VST were enrolled. Subsequently, 272 breasts were subjected to bilateral whole-breast ultrasound examinations using ABUS and the hand-held ultrasound system (HHUS). During ABUS image acquisition, one breast was scanned with 2-VST, while the other breast was scanned with 3-VST. In each breast, the breast coverage and visibility of the HHUS detected lesions on ABUS were assessed. The sensitivity and specificity of ABUS were compared between 2-VST and 3-VST. Results: Among 136 breasts, eight cases of breast cancer were detected by 2-VST, and 10 cases of breast cancer were detected by 3-VST. The breast coverage was satisfactory in 94.1% and 91.9% of cases under 2-VST and 3-VST, respectively (p = 0.318). All HHUS-detected lesions were visible on the ABUS images regardless of the scan technique. The sensitivities and specificities were similar between 2-VST and 3-VST (100% [8/8] vs. 100% [10/10], and 97.7% [125/128] vs. 95.2% [120/126], respectively), with no significant difference (p > 0.05). Conclusion: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.

Classification Analysis of the Physical Environment of Bicycle Road -Focused on Chang Won City, Kyung Nam Province, S. Korea- (자전거 도로의 물리적 환경에 대한 등급화 연구 -창원시 사례를 중심으로-)

  • Moon, Ho-Gyeong;Kim, Dong-Pil;Choi, Song-Hyun;Kwon, Jin-O
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.3
    • /
    • pp.365-373
    • /
    • 2014
  • This study is to analyze the physical environment and conduct spatial data for bicycle road system in changwon. Index for evaluation index was developed based on literatures. Then the level of importance and weight have been modified through experts review. Finally, index with eight categories such as greenness(40% over), bicycle road connectivity(1.8, 9.8%), road type bike(bicycle lane, 24.4%), pave type(asphalt 72.5%), illegal parking(none, 93.9%), bike road surface visibility(exist, 46.8%), vehicle speed limits(30km, under), vehicle traffic(500/hr under, 44.3%) have been applied to empirical investigation. Collected data has been hierarchically classification by ArcGIS Program. The Highest grades(score 31-35, level 1) occupied 35% of target destination. High level of greenness and load type has contributed to high score. In addition, average level of greenness of those destination was 35% and higher, which provide high degree of security and freshness for bicycle riding. Meanwhile, lowest level(level 5, which earned 15 point or less) occupied 24.5%. illegal parking, low level of greenness, and no surface sign caused low score.

A Study on the Objects Arrangement of Display Panel and the Cognitive Accuracy under the Virtual Reality Evaluation Tool (가상현실 기법을 적용한 평가도구를 활용한 계기반 배치 및 인지 정확도에 관한 연구)

  • Kim, Sun-young;Yu, Seung-dong;Park, Peom
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • Most of the important visual information is presented to driver through the display panel that is related to the vehicle. If display panel is designed with the c consideration of driver's visibility, drivers can get broad visual field and visual I information related to vehicle promptly and exactly during driving situation. Therefore display panel has direct relationship with the driver's task performance and it can be considered as an important device that affects the driver-automotive interaction. Many r researches about shape, characteristic and color of display panel have been performed, but not sufficient in this country Nowadays most of vehicles has an analog type display. but its shape and arrangement a are various without any definite standards about position. Therefore. experiments using evaluation tool (VISVEC System) were conducted to inquire the driver's preference on the major objects arrangement of display panel (speedometer. tachometer. fuel meter. and t thermometer) and to ascertain the factors that have an effect on drivers according to the objects position of the display panel The experiment results showed that there was no correlation between the arrangement c characteristics preferred by subjects and the cognitive accuracy but the cognition of V visual information more easy when the each major object has its area.

  • PDF

Role of MRI in Diagnostic Evaluation of Papillary Lesions of the Breast (유방의 유두상 병변의 진단에서 자기공명영상의 역할)

  • Lee, So-Mi;Kim, Hye-Jung;Gwak, Yeon-Joo;Lee, Hui-Joong;Jang, Yun-Jin;Shin, Kyung-Min;Park, Ji-Young;Jung, Jin-Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose : To evaluate the role of magnetic resonance imaging (MRI) in the diagnosis of papillary lesions of the breast. Materials and methods : Among 45 papillary lesions diagnosed at ultrasonography-guided core biopsy (USCB), 27 benign papillary lesions in 22 patients who underwent breast MRI were reviewed. The excsional biopsy was performed in 1-10 days after MRI was done. In MRI findings, lesions were considered suspicious if they show irregular, rim enhancement, or linear enhancement in morphologic evaluation, or washout enhancement pattern of delayed phase in dynamic enhancement characteristics. Diffusionweighted images were analyzed according to visibility of lesions. MRI findings were correlated with pathologic results at excisional biopsy. Results : At excisional biopsy, two lesions (9%) were diagnosed malignant in 22 benign papillary lesions without atypia by USCB and 4 (80%) were malignant in 5 benign papillary lesions with atypia by USCB. Among 18 lesions detected on MRI, 16 lesions showed suspicious findings on MRI, 11 lesions (69%) were diagnosed as benign and 5 (31%) were malignant. Among 12 lesions detected on diffusion weighted imaging, 10 lesions were diagnosed as benign and 2 were malignant. MRI findings were not significantly correlated with pathologic results at excisional biopsy. Conclusion : MRI findings were not useful to predict malignancy in benign papillary lesions diagnosed at USCB, because MRI findings of these were mostly suspicious (88.9%, 16/18). The benign papillary lesion should be included in the false positive lesion on breast MRI.