• Title/Summary/Keyword: Visibility Distance

Search Result 118, Processing Time 0.019 seconds

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

Appropriateness Assessment of Illuminance-Based Evaluation Method in Automotive Headlight Visibility Performance (조도 기반 자동차 전조등 시인 성능 평가 방법의 적정성 평가)

  • Cho, Wonbum
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.165-173
    • /
    • 2017
  • PURPOSES : The current practice in car headlight visibility performance evaluation is based on the luminous intensity and illuminance of headlight. Such practice can be inappropriate from a visibility point of view where visibility indicates abilities to perceive an object ahead on the road. This study aimed at evaluating the appropriateness of current headlight evaluation method. METHODS : This study measured the luminance of object and road surface at unlit roadways. The variables were measured by vehicle type and by headlight lamp type. Based on the measurements, the distance where drivers can perceive an object ahead was calculated and then compared against such distance obtained by conventional visibility performance evaluation. RESULTS : The evaluation method based on illuminance of headlight is not appropriate when viewed from the visibility concept that is based on object-perceivable distance. Further, the results indicated a shorter object-perceiving distance even when road surface luminance is higher, thereby suggesting that illuminance of headlight and luminance of road surface are not the representative indices of nighttime visibility. CONCLUSIONS : Considering that this study utilized limited vehicle types and that road surface (background) luminance can vary depending on the characteristics of the given road surface, it would likely go too far to argue that this study's visibility performance evaluation results can get generalized to other conditions. Regardless, there is little doubt that the current performance evaluation criterion which is based on illuminance, is unreasonable. There should be future endeavors on the current subject which will need to explore study conditions further, under which more experiments should be conducted and effective methodologies developed for evaluating automotive headlight visibility performance. Needs are recognized particularly in the development of headlight visibility performance evaluation methodology which will take into account road surface (background) luminance and luminance contrast from various perspectives as the former indicates the driver's perception of the front road alignment and the latter being indicative of object perception performance.

Fog Generated Field Test for Criteria of Sign Size of Variable Speed Limit Signs (가변 제한속도 표지판 크기기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.87-96
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between different sizes of variable speed limit signs and the legibility distance under various fog density conditions. By using this study, appropriate sizes of signs can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area for this test, as other places cannot maintain the fog condition because of rapid air current. A total 121 subjects were recruited for this test, which took place over the course of four days. The test on the first day was conducted under normal weather conditions for comparison. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between the different sizes of signs and the legibility distance corresponding to the visibility distance due to both non-fog and fog generated conditions. According to the technical test results, appreciable amount of reduction in legibility distance due to fog was resulted in all sizes of signs. Moreover, the legibility distance is reduced proportionately with the decrease in the visibility distance due to fog. CONCLUSIONS : The results of this study can be used to select appropriate sizes of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

A study on the analysis technique of visual information by GIS (GIS를 이용한 가시권정보 분석기법에 관한 연구 -제주 산방산 지역 사례연구-)

  • 최기만;이춘석;임승빈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.2
    • /
    • pp.31-42
    • /
    • 1997
  • Visibility has been used for Visual Impact Assessment and Buildingheight Control. The purpose of this study is to elaborate visibility analysis technique in GIS, and to design a visual information system baed on this technique for diverse application. The results of this study are as follows : 1) By classifying visibility analysis techniques into two groups, Each one's merits and demerits were investigated. Practically GIS visibility analysis by DTM model using contour map and investigating it by means of site-observation can be the most effective method. 2) A visibility analysis techniquwe for V.I.A. and B.H.C. was presented by studying GIS visibility analysis by means of DTM model using contour map. There were 5 problems. 3) Adequate analysis techniques were presented according to the landscape factor-road, ship-route, port, mountain, etc. 4) Viewing distance from road and ship-route in visual corridor, landma가 visibility and distance, the angle of incidence and invisible region's depth are helpful for land scape management or land use planning.

  • PDF

Visibility detection approach to road scene foggy images

  • Guo, Fan;Peng, Hui;Tang, Jin;Zou, Beiji;Tang, Chenggong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4419-4441
    • /
    • 2016
  • A cause of vehicle accidents is the reduced visibility due to bad weather conditions such as fog. Therefore, an onboard vision system should take visibility detection into account. In this paper, we propose a simple and effective approach for measuring the visibility distance using a single camera placed onboard a moving vehicle. The proposed algorithm is controlled by a few parameters and mainly includes camera parameter estimation, region of interest (ROI) estimation and visibility computation. Thanks to the ROI extraction, the position of the inflection point may be measured in practice. Thus, combined with the estimated camera parameters, the visibility distance of the input foggy image can be computed with a single camera and just the presence of road and sky in the scene. To assess the accuracy of the proposed approach, a reference target based visibility detection method is also introduced. The comparative study and quantitative evaluation show that the proposed method can obtain good visibility detection results with relatively fast speed.

A Study on the Visibility Analysis Model for the Ward of General Hospital Considering Nurse's Circulation (종합병원 병동부 간호 이동 동선을 고려한 가시 특성 분석 모델에 관한 연구)

  • Kim, Seo-Yeong;Kweon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.71-80
    • /
    • 2018
  • The path and visibility of nurses in general hospital wards have been treated as architectural planning factors. However, the analysis approach of existing studies shows limitations that only fixed physical elements are considered without considering the behavior of users using space. Consider factors for analysis of ward and models based on this study model. Select a case hospital to apply the analysis technique and conduct the nurse questionnaire and route survey of the hospital. Establish a framework for analysis model applied with the path of nurse movements. The analysis model applies to the case hospital. The analysis results are aggregated to derive design suggestion for reference to the spatial improvement of the ward. Visible visibility to observe the bedside in the nursing station, visibility to observe the beds in the nurse's path, and visibility to observe patients moving in the nurse's path were derived from visual access frequency and exposure frequency. The survey of nurses' movements at the site allowed the nurses to calculate the distance required to move. Reflecting the path of nurse movement, a model was presented for a comprehensive analysis of nursing distance and nursing visibility, which could lead to improvement in the observation and visibility of nurses and the layout of patient rooms or day rooms.

Reliability of spiral tomography on the alveolar crest (나선형 단층 방사선사진에서 치조정 판독 신뢰도)

  • Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.123-128
    • /
    • 2004
  • Purpose: To evaluate the reliability of measurements in spiral tomography through assessing the visibility of the alveolar crest and the measurements between the alveolar crest and other anatomic structures. Materials and Methods: 110 spiral tomograms of the jaws were taken by Scanora X-ray unit from the patients. The visibility of the alveolar crests was estimated by 3 observers and classified as clearly visible, questionable visibility, or not visible. 3 observers measured the distance between the alveolar crest and the reference points of anatomic structures. The measurements were repeated 2 weeks later. Results: 52.9% of alveolar crests on upper jaws and 61.5% of alveolar crests on lower jaws were visible. The interobserver and intraobserver agreements on the visibility were low. The mean ranges of the measurements were 1.39 mm (SD = 1.37 mm) on maxilla and 1.03 mm (SD = 1.01 mm) on mandible in the interobserver evaluation. The interobserver variance was greater than the intraobserver variance in the measurements of distance. Conclusion: Spiral tomography showed a relatively low reliability in the visibility and measurements of the alveolar crest.

  • PDF

Fog Generated Field Test for Luminance Criteria of Variable Speed-Limit Signs (가변속도형 표지 휘도기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.77-85
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between the luminance of variable speed-limit signs and the legibility distance under various fog density conditions. By using this study, appropriate luminance values can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area to conduct the test, as other places cannot maintain the fog condition because of rapid air current. Ninety-two subjects were recruited for this test, which took place during the course of three days. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between luminance values and the legibility distance corresponding to the visibility distance due to fog. According to the technical test results, lower luminance value such as $7000cd/m^2$ corresponds to less legibility distance compared to higher values such as $20000cd/m^2$ or $40000cd/m^2$. However, the amount of difference between $20000cd/m^2$ and $40000cd/m^2$ is negligible in our test. CONCLUSIONS : The results of this study can be used to select appropriate luminance of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

A Study of Signal Visibility according to the Distance of Clothing for Micro-mobility Users using FOLED (FOLED를 이용한 마이크로 모빌리티 사용자용 의류의 거리에 따른 시그널 가시성 연구)

  • Choi, Hyunseuk;Lee, Jihye;Jang, Hyunmi;Hong, Sungmin
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.288-301
    • /
    • 2021
  • The purpose of this study was to verify the degree of visibility of FOLED (fiber optic light-emitting diode) materials applied to safety-enhancing clothes of micro-mobility users during the day and night by conducting an empirical test targeting 50 people in their teens, 20's, 30's, 40's, and 50's or older. First, the results of the visibility test at 10 m-intervals from 10 to 70 m based on the clothes sample showed that the light detection of FOLED material was very good without daytime or night-time distinction. Second, the results of directional sign detection of FOLED were confirmed to be very high without any daytime or night. Third, the results of identifying a pictogram design showed that the distance was shorter than that of light detection or directional indication. However, the FOLED pictogram design could be confirmed at a distance of 50 m or less. Therefore, if a clothes product using FOLED material is worn and micro-mobility is used, the experimental results indicate that safety will be sufficiently secured due to the excellent visibility.

Development of Legibility Distance Models for Each Color according to Luminance under Foggy Condition (안개시 휘도에 따른 색상별 판독거리 산출 모형 개발)

  • Kim, Chul-Yong;Lee, Sang-Soo;Youn, IL-Soo;Oh, Ju-sam
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.3
    • /
    • pp.52-61
    • /
    • 2020
  • This study developed a legibility distance(LD) model for three colors used in VMS according to luminance under foggy conditions through experiments. For this, a simulated environment was created, and LD values of red, green, and yellow color were collected by increasing the luminance. From the test results, the LDs for red at luminance levels of 2,000 cd/㎡ and 20,000 cd/㎡ and a visibility distance of 10m were 10.2m and 18.8m, respectively, which was an improvement of 84%. The LD was improved by 34% and 17% at a visibility distance of 20 m and 30 m, respectively. For green, the LD was improved by 69%, 63%, and 19% at visibility distance of 10m, 20m, 30m, respectively. For yellow, the LD was improved by 100%, 47%, and 36% at visibility distance of 10m, 20m, 30m, respectively. The LD models for three colors were developed by using two independent variables, luminance value and visibility distance. The adjusted coefficients of the red, green, and yellow model equations were calculated as 0.982, 0.978, and 0.915, respectively, and the explanatory power of all models was very high.