• 제목/요약/키워드: Viscous Cooling Fan

검색결과 9건 처리시간 0.022초

냉각팬 전동화에 따른 시내버스 연비효과 예측 (Prediction of the Effect of Cooling Fan Electrification on City Bus)

  • 이용규;박진일;이종화
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.908-912
    • /
    • 2013
  • Because of their longer operating times and larger size relative to conventional fans, the cooling fans mounted in buses consume larger amounts of energy. Most of the cooling fans mounted in a bus are connected to the engine by a viscous clutch. A viscous cooling fan's speed is determined by its fluid temperature, which is affected by the air flow through the radiator. The fan does not react immediately to the coolant temperature and in doing so causes unnecessary energy consumption. Therefore, the fuel economy of buses using viscous fans can be improved by changing to an electric cooling fan design, which can be actively controlled. In addition, electric power consumption is increased by using electric cooling fans. Thus, when electric fans are applied in conjunction with the alternator management system (AMS), the fuel economy is further enhanced. In this study, simulations were performed to predict coolant temperature and cooling fan speeds. Simulations were performed for both viscous and electric cooling fans, and power consumption was calculated. Additionally, fuel economy was calculated applying both the alternator management system and the electric cooling fan.

자동차 프런트 엔드 쿨링팬 주위의 점성유동 해석 (Numerical Analysis of the Viscous Flow Around a Front End Cooling Fan of the Car)

  • 오건제;배춘근
    • 한국산업융합학회 논문집
    • /
    • 제10권4호
    • /
    • pp.221-226
    • /
    • 2007
  • Viscous flow around a front end cooling fan of the car is numerically investigated. The Navier-Stokes equations and the continuity equation are solved in the flow domain. The Reynolds stresses are modelled using the $k-{\varepsilon}$ turbulence model. The governing equations are discretized with the Finite Volume Method. The pressure and the velocity are linked with the SIMPLE algorithm. Flow and pressure characteristics around the fan are investigated. The pressure sharply increases through the fan blade. Pressure variations on the pressure and suction sides of the fan are well represened in the calculations. The flow streamlines in the blade passage are nearly parallel to the blade, but the slope of streamlines increases near the tip.

  • PDF

냉각팬 전자제어를 통한 시내버스의 연비 개선 (The Effect of Cooling Fan Control on Fuel Economy of City Bus)

  • 김기복;박진일;이종화;박경석
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.1-7
    • /
    • 2013
  • This paper focuses on cooling fan control by using a magnetic clutch type for the improvement of fuel economy on a heavy city bus. In general, Heavy duty vehicles use viscous clutch type cooling fan which has some disadvantages, such as slow response, wide temperature variation of engine coolant water. But a magnetic clutch type cooling fan can be controlled electronically so the engine coolant temperature can be precisely controllable and this effects could be used to reduce fuel consumption. A control system for applying the magnetic clutch type cooling fan was developed in this study and applied to the real field test and chassis dynamometer test. The result showed well controlled coolant temperature and enhancement of fuel economy.

자동차 프런트 엔드 쿨링팬 주위의 점성유동 해석 (Analysis of the Viscous Flow Around a Front End Cooling Fan)

  • 배춘근;오건제;조원봉;주필호;김종철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1371-1376
    • /
    • 2004
  • Flow analysis of automobile front-end cooling fan are numerically investigated. The Navier-Stokes equations and the continuity equation are solved in the flow domain. The Reynolds stresses are modelled using the $k-{\varepsilon}$ turbulence model. Flow and pressure characteristics around the fan are investigated. The pressure sharply increases through the fan. Pressure variations on the pressure and suction sides of the fan are well represented in the calculations. The flow streamlines in the blade passage are nearly parallel to the blade.

  • PDF

스윕을 가진 냉각탑용 쿨링팬 주위의 점성유동 해석 (Numerical Analysis of the Viscous Flow around a Cooling Tower Fan with Sweep)

  • 오건제
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.33-39
    • /
    • 2004
  • Viscous flows around a cooling tower fan with sweep are numerically investigated. The Navier-Stokes equations and the continuity equation are solved in the flow domain. The Reynolds stresses are modelled using the $\kappa-{\varepsilon}$ turbulence model. The governing equations are discretized with the Finite Volume Method. The pressure and the velocity are linked with the SIMPLE algorithme. Flow and pressure characteristics around the fan are investigated. The pressure sharply increases through the fan. Pressure variations on the pressure and suction sides of the fan are well represened in the calculations. The flow streamlines in the blade passage are nearly parallel to the blade.

  • PDF

스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구 (Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep)

  • 오건제
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

홀 센서 기반 전자식 엔진냉각제어 시스템 설계 (Design of Hall Sensor based Electronic Engine Cooling System)

  • 고영호;김현희;이경창
    • 한국산업융합학회 논문집
    • /
    • 제20권4호
    • /
    • pp.325-332
    • /
    • 2017
  • The engine cooling system is a device that maintains the temperature in the engine room at an appropriate level by driving a cooling fan when the temperature in the engine room generated during the vehicle operation occurs over a certain temperature. In recent years, the vehicle cooling system has changed to an electronic system. Therefore, in this paper, we design and develop a hall sensor based electronic engine cooling system. In this paper, a hall sensor module and an actuator module for engine cooling control system are designed. In order to verify the performance of the designed module, the magnetic field control was verified through the simulation of the diameter and the head of the coil.

차량용 MR 홴 클러치 설계 및 제어 (Design and Control of MR Fan Clutch for Automotive Application)

  • 김은석;손정우;최승복
    • 한국소음진동공학회논문집
    • /
    • 제19권8호
    • /
    • pp.795-801
    • /
    • 2009
  • This paper presents an optimal design of a magnetorheological(MR) fan clutch based on finite element analysis and also presents torque control of engine cooling fan using a sliding mode control. The MR fan clutch is constrained in a specific volume and the optimization problem identifies the geometric dimension of the fan clutch that minimizes an objective function. The objective function for the optimization problem is determined based on the solution of the magnetic circuit of the initially designed clutch. Under consideration of spatial limitation, design parameters are optimally determined using finite element analysis. After describing the configuration of the MR fan clutch, the viscous torque and controllable torque are obtained on the basis of the Bingham model of MR fluid. Then, a sliding mode controller is designed to control the torque of the fan clutch according to engine room temperature and control performance is evaluated through computer simulation.

차량용 MR 팬 클러치 설계 및 제어 (Design and Control of MR Fan Clutch for Automotive Application)

  • 김은석;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.633-638
    • /
    • 2009
  • This paper presents an optimal design of a magnetorheological(MR) fan clutch based on finite element analysis and also presents torque control of engine cooling fan using a sliding mode control. The MR fan clutch is constrained in a specific volume and the optimization problem identifies the geometric dimension of the fan clutch that minimizes an objective function. The objective function for the optimization problem is determined based on the solution of the magnetic circuit of the initially designed clutch. Under consideration of spatial limitation, design parameters are optimally determined using finite element analysis. After describing the configuration of the MR fan clutch, the viscous torque and controllable torque are obtained on the basis of the Bingham model of MR fluid. Then, a sliding mode controller is designed to control the torque of the fan clutch according to engine room temperature and control performance is evaluated through computer simulation.

  • PDF