• Title/Summary/Keyword: Virtual patients

Search Result 275, Processing Time 0.034 seconds

Application of PERT/CPM in dental practice (PERT/CPM의 치과임상에의 적용)

  • Kim, Bo-Kuk;Kim, Jae-Hyun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.186-194
    • /
    • 2014
  • Purpose: Process management is the activity which manages all procedure of construction by representing visually interrelation of operation or sequence setting. The purpose of this study was for reducing treatment period and higher efficiency of treatment through application of PERT/CPM (Program Evaluation & Review Technique/Critical Path Method) in dental clinic. Materials and methods: The patients were selected for study who needed more than 2 departments' cooperation for prosthodontic treatment in Wonkwang Dental University Hospital. Control group is composed of the patient's whole treatment plan, treatment period, numbers of hospital visit, treatment costs, treatment results. On the other hand, experiment group contains the patient's virtual treatment data based on PERT/CPM technique. We applied PERT/CPM in operation analysis. Results: Treatment period, numbers of hospital visit was decreased as 18.1% and 15.3% when we applied operation analysis based on charts. Also treatment cost in experiment group was 0.9% economized compared with control group's treatment cost. Conclusion: Application of PERT/CPM in dental clinic can achieve reliable treatment and reduced treatment period and establish plan of minimum treatment cost.

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

Chest-wall Surface Dose During Post-mastectomy Radiation Therapy, with and without Nonmagnetic Bolus: A Phantom Study

  • Choi, Cheon Woong;Hong, Joo Wan;Park, Cheol Soo;Ahn, Jae Ouk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.293-297
    • /
    • 2016
  • For mastectomy patients, sufficient doses of radiation should be delivered to the surface of the chest wall to prevent recurrence. A bolus is used to increase the surface dose on the chest wall, whereby the surface dose is confirmed with the use of a virtual bolus during the computerized treatment-planning process. The purpose of this study is an examination of the difference between the dose of the computerized treatment plan and the dose that is measured on the bolus. Part of the left breast of an Anderson Rando phantom was removed, followed by the attainment of computed tomography (CT) images that were used as the basis for computerized treatment plans that were established with no bolus, a 3 mm-thick bolus, a 5 mm-thick bolus, and a 10 mm-thick bolus. For the computerized treatment plan, a prescribed dose regimen was dispensed daily and planning target volume (PTV) coverage was applied according to the RTOG 1304 guidelines. Using each of the established computerized treatment plans, chest-wall doses of 5 points were measured; this chest-wall dose was used as the standard for the analysis of this study, while the level of significance was set at P < 0.05. The measurement of the chest-wall dose with no bolus is 1.6 % to 10.3 % higher, and the differences of the minimum average and the maximum average of the five measurement points are -13.8 and -1.9, respectively (P < 0.05); however, when the bolus was used, the dosage was measured as 3.7 % to 9.2 % lower, and the differences of the minimum average and the maximum average are 7.4 and 9.0, -1.2 and 17.4, and 8.1 and 19.8 for 3 mm, 5 mm, and 10 mm, respectively (P < 0.05). As the thickness of the bolus is increased, the differences of the average surface dose are further increased. There are a variety of factors that affect the surface dose on the chest wall during post-mastectomy radiation therapy, for which verification is required; in particular, a consideration of the appropriate thickness and the number of uses when a bolus is used, and which has the greatest effect on the surface dose on the chest wall, is considered necessary.

Measuring Quality of Life in Cerebral Palsy Children According to the Severity Using the Visual Analogue Scale, Time Trade-Off, and EQ-5D-Y Proxy (뇌성마비 환아 중증도별 시각화척도, 시간교환법, EQ-5D-Y Proxy를 이용한 삶의 질 측정)

  • Lee, Go-Eun;Kim, Nam Kwen;Yun, Young Ju;Wang, Hye Min;Kim, Jeong Hun;Lee, Dong Hyo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.28 no.2
    • /
    • pp.49-59
    • /
    • 2017
  • Objectives: To measure the quality of life in patients according to virtual cerebral palsy severity by using the Korean version of EQ-5D-Y proxy, Visual Analogue Scale (VAS), and Time Trade-Off method (TTO). Methods: The study was conducted in parents of children and adolescents aged 4 to 15 years in Seoul. We analyzed the difference in the utility value according to five levels of cerebral palsy severity in the Gross Motor Function Classification System (GMFCS) and test-retest reliability. Results: 1. There were significant differences in VAS, TTO, and EQ-5D-Y proxy according to the cerebral palsy severity (p<.001). 2. VAS was significantly different according to the respondent's visit to the medical institution, the presence of disease in the respondent, a visit to the child's medical institution, the age of the child, and the sex of the child. The value of TTO was significantly different according to the respondent's visit to the medical institution, respondent's sex, and the age of the child. Also, EQ-5D-Y proxy was significantly different according to the age of the child. 3. Intraclass correlation coefficient values were more than 0.6 for both VAS and TTO at all stages. But for the EQ-5D-Y proxy, the value was less than 0.6 at all stages. Conclusions: The quality of life assessment using EQ-5D-Y proxy showed significant differences in the severity of cerebral palsy. However, large-scale studies using EQ-5D-Y proxy are needed because of low test-retest reliability.

A Comparative Study of Block Chain : Bitcoin·Namecoin·MediBloc (블록체인 비교연구: 비트코인·네임코인·메디블록)

  • Kim, Ji Yeon
    • Journal of Science and Technology Studies
    • /
    • v.18 no.3
    • /
    • pp.217-255
    • /
    • 2018
  • Bitcoin, which appeared in 2008, was merely a conceptual virtual currency, but it now enjoys the status as actual money. Bitcoin is an electronic money system that can be traded directly without a central trust institution. Thanks to the popularization of Bitcoin, blockchain technology has become a widespread concern. That technology is expanding not only the currency mechanism, but also a variety of other services. The possibility of a blockchain in relation to actual currency is ongoing. This paper investigates the technological characteristics and social construction of the blockchain by comparing the cases of Bitcoin, Namecoin, and MediBloc among blockchain applications. Namecoin emerged in 2013 is an attempt to replace the centralized Internet Domain Name System(DNS). There has been controversy over that current system for a long time, but replacing the already established system is not easy. Nevertheless, Namecoin has potential as an alternative. Meanwhile, MediBloc is an application that involves distributed management of medical data in South Korea. MediBloc claims that the key producers of medical data are patients themselves. This is to challenge to the question who is a knowledge producer of medical data. Through these three cases, it has discussed that blockchain technology does supports to form more democratic decision-making or simply provide a technical solution as automation. As a citizen, we can intervene in the realization of blockchains by presenting social agenda. This will be a method of the social construction of technology.

Analysis of domestic research trends related to the development of digital therapeutics (DTx) in the field of communication disorders (의사소통장애 분야에서 디지털 치료제(DTx) 개발과 관련된 국내 연구동향 분석)

  • Eunmi Yun;Ikjae Im
    • Phonetics and Speech Sciences
    • /
    • v.14 no.4
    • /
    • pp.57-66
    • /
    • 2022
  • In this study, the definition of "digital therapeutics" was clarified by examining related studies, and the development trend of digital therapeutics at the domestic level was investigated. Further, research data and technologies applied to various communication disorders since 2015 were analyzed. From all these, digital therapeutics can be defined as software that can support evidence-based treatment when used on patients to prevent, manage, and treat disorders With huge investments and research efforts increasingly made in the field of digital therapeutics, 17 of the 22 studies examined were on digital therapeutics applied in the treatment of language disorders. In the research papers examined, the technologies applied were virtual reality and augmented reality, with augmented reality used in most cases. The effects of applying digital treatment were positive, and most studies focused on content development in relation to the development of digital treatment, although one study was conducted for app development. Future studies could examine the application of digital therapeutics to more diverse communication disorder subjects. Active government support is expected in developing more sophisticated software that can be applied using a wider range of technologies in the field of digital therapeutics to treat more communication disorders.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

Esthetic restoration of maxillary anterior teeth considering facial features in digital diagnostic wax-up: a case report (디지털 진단 왁스업을 통하여 안모를 고려한 상악 전치부 심미수복 증례)

  • Sung-Ji Gong;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park;Woohyung Jang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.179-188
    • /
    • 2024
  • To enhance the predictability of aesthetic treatment outcomes in aesthetic prosthetic restorations, considerations must include analysis of facial features, the relationship between teeth and lips, proportions of tooth width/length, gingival form, and more. Traditional diagnostic wax-ups have limitations in considering the patient's facial features and are unable to facilitate rapid form modifications. With recent advancements in digital technology, it is now possible to digitize the patient's facial features in three dimensions, enabling the design of restorations that harmonize with facial features. These digital workflows not only improve efficiency but also provide patients with faster visualization of treatment outcomes, thereby enhancing motivation. Therefore, in this case, a treatment plan is devised to utilize digital diagnostic wax-ups considering the patient's facial features for the final prosthetic design.

Treatment Planning for Minimizing Carotid Artery Dose in the Radiotherapy of Early Glottic Cancer (조기 성문암의 방사선치료에서 경동맥을 보호하기 위한 치료 계획)

  • Ki, Yang-Kan;Kim, Won-Taek;Nam, Ji- Ho;Kim, Dong-Hyun;Lee, Ju-Hye;Park, Dal;Kim, Don-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Purpose: To examine the feasibility of the treatment planning for minimizing carotid artery dose in the radiotherapy of early glottic cancer. Materials and Methods: From 2007 to 2010, computed tomography simulation images of 31 patients treated by radiotherapy for early glottic cancer were analyzed. The virtual planning was used to compare the parallel-opposing fields (POF) with the modified oblique fields (MOF) placed at angles to exclude the ipsilateral carotid arteries. Planning target volume (PTV), irradiated volume, carotid artery, and spinal cord were analyzed at a mean dose, $V_{35}$, $V_{40}$, $V_{50}$ and with a percent dose-volume. Results: The beam angles were arranged 25 degrees anteriorly in 23 patients and 30 degrees anteriorly in 8 dose-volume of carotid artery shows the significant difference (p<0.001). The mean doses of carotid artery were 38.5 Gy for POF and 26.3 Gy for MOF and the difference was statistically significant (p=0.012). Similarly, $V_{35}$, $V_{40}$, and $V_{50}$ also showed significant differences between POF and MOF. Conclusion: The modified oblique field was respected to prevent a carotid artery stenosis and reduce the incidence of a stroke based on these results.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.