• Title/Summary/Keyword: Virtual methods

Search Result 1,426, Processing Time 0.028 seconds

Development of a Remote Wheelchair Accessibility Assessment System Using Virtualized Reality Technology (가상현실기술을 이용한 원격휠체어접근성평가시스템의 개발)

  • Kim, Jong-Bae
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.33-39
    • /
    • 2006
  • Home modification has come to be recognized as an important intervention strategy to manage health care conditions, maintain or improve functioning, ensure safety, and reduce the wheelchair user's dependency on others. However, the availability of skilled professionals with experience in home modifications for accessibility is limited. A system that enables accurate remote assessments would be an important tool to improve our ability to perform home assessments more easily and at decreased cost. A Remote Wheelchair Accessibility Assessment System (RWAAS) using Virtualized Reality(VR) technology was developed that enabled clinicians to assess the wheelchair accessibility of users' built environments from a remote location. Characteristics of the camera and 3D reconstruction program chosen for the system significantly affect its overall reliability. In this study, we performed two reliability analyses on the hardware and software components: 1) Verification that commercial software can construct sufficiently accurate 3D models by analyzing the accuracy of dimensional measurements in a virtualized environment; 2) comparison of dimensional measurements with four camera settings. Based on these two analyses, we were able to specify a consumer level digital camera and the Photomodeler Pro software for this system. And we then tested the feasibility of the selected software and hardware in an actual environment. Lastly, A field evaluation was performed to test whether this new system is comparable to the traditional method of accessibility assessment to evaluate its ability to assess the accessibility of a wheelchair user's typical built environment. The results of field trials showed high congruence between the assessments by two methods. Findings suggested that the RWAAS assessments have the potential to enable specialists to assess potential accessibility problems in built environments regardless of the location of the client, home, or specialist.

  • PDF

Comparative Reverse Screening Approach to Identify Potential Anti-neoplastic Targets of Saffron Functional Components and Binding Mode

  • Bhattacharjee, Biplab;Vijayasarathy, Sandhya;Karunakar, Prashantha;Chatterjee, Jhinuk
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5605-5611
    • /
    • 2012
  • Background: In the last two decades, pioneering research on anti-tumour activity of saffron has shed light on the role of crocetin, picrocrocin and safranal, as broad spectrum anti-neoplastic agents. However, the exact mechanisms have yet to be elucidated. Identification and characterization of the targets of bioactive constituents will play an imperative role in demystifying the complex anti-neoplastic machinery. Methods: In the quest of potential target identification, a dual virtual screening approach utilizing two inverse screening systems, one predicated on idTarget and the other on PharmMapper was here employed. A set of target proteins associated with multiple forms of cancer and ranked by Fit Score and Binding energy were obtained from the two independent inverse screening platforms. The validity of the results was checked by meticulously analyzing the post-docking binding pose of the picrocrocin with Hsp90 alpha in AutoDock. Results: The docking pose reveals that electrostatic and hydrogen bonds play the key role in inter-molecular interactions in ligand binding. Picrocrocin binds to the Hsp90 alpha with a definite orientation appropriate for nucleophilic attacks by several electrical residues inside the Hsp90-alpha ATPase catalytic site. Conclusion: This study reveals functional information about the anti-tumor mechanism of saffron bioactive constituents. Also, a tractable set of anti-neoplastic targets for saffron has been generated in this study which can be further authenticated by in vivo and in vitro experiments.

Review of Psychological Treatment for Post-Traumatic Stress Disorder : Focus on Survivors of Disaster (외상후 스트레스 장애에 대한 심리치료 효과 개관 : 재난 생존자를 중심으로)

  • Jang, Eun-Young;Lee, Hyunji;Kim, Daeho
    • Anxiety and mood
    • /
    • v.12 no.2
    • /
    • pp.69-78
    • /
    • 2016
  • Objective : Disaster causes psychological distress to a large number of people in a short period of time, by both direct and indirect exposure to traumatic events embedded in various realms of disaster experience. Optimal, well-planned treatment interventions should follow from the early acute period to recovery phase, extending up to several months later. In this context, there is an increasing need for systemic review to gain comprehensive insights for disaster interventions. These need to be added to public policy, and for the prevention and treatment of disaster-related psychopathology. Here, we review the published studies on psychological interventions for disaster-related posttraumatic stress disorder. Methods : Specific psychological interventions regarded as effective treatments for have been selected for this review, such as CBT (Cognitive-Behavior Therapy), Exposure Therapy, EMDR (Eye Movement Desensitization & Reprocessing), SIT (Stress Inoculation Therapy) and Psychoeducation. In addition, natural disasters, industrial disasters, and accidents involving aircraft and ships were also categorized as disasters, along with war and combat trauma. Results : Cognitive behavior therapy and exposure therapy had the strongest research support for effectiveness, and could be considered as the first-choice treatment for disaster-related PTSD. The second line of treatment is EMDR, although this treatment modality has the advantage of reaching certain treatment improvements in fewer sessions. However, the effects of SIT and psychoeducation to the survivors of disasters, remains unclear at this point. Additionally, we propose the possibilities of using virtual reality component and imagery rescripting as modified forms of traditional cognitive behavior therapy and exposure therapy. Conclusion : Cognitive behavior therapy and exposure therapy, deemed effective treatments for various trauma, are considered to be effective for survivors from disasters. However, the efficacy of other interventions has not yet been examined methodologically in well-designed studies, such as randomized controlled trials. In particular, future empirical studies are needed, since it is difficult to conclude that psychological interventions have similar effects on different types of disasters.

  • PDF

Integration of Laser Scanning and Three-dimensional Models in the Legal Process Following an Industrial Accident

  • Eyre, Matthew;Foster, Patrick;Speake, Georgina;Coggan, John
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.306-314
    • /
    • 2017
  • Background: In order to obtain a deeper understanding of an incident, it needs to be investigated to "peel back the layers" and examine both immediate and underlying failures that contributed to the event itself. One of the key elements of an effective accident investigation is recording the scene for future reference. In recent years, however, there have been major advances in survey technology, which have provided the ability to capture scenes in three dimension to an unprecedented level of detail, using laser scanners. Methods: A case study involving a fatal incident was surveyed using three-dimensional laser scanning, and subsequently recreated through virtual and physical models. The created models were then utilized in both accident investigation and legal process, to explore the technologies used in this setting. Results: Benefits include explanation of the event and environment, incident reconstruction, preservation of evidence, reducing the need for site visits, and testing of theories. Drawbacks include limited technology within courtrooms, confusion caused by models, cost, and personal interpretation and acceptance in the data. Conclusion: Laser scanning surveys can be of considerable use in jury trials, for example, in case the location supports the use of a high-definition survey, or an object has to be altered after the accident and it has a specific influence on the case and needs to be recorded. However, consideration has to be made in its application and to ensure a fair trial, with emphasis being placed on the facts of the case and personal interpretation controlled.

Comparison of Diagnostic Accuracies of Serum HE-4 Levels and 3D Power Doppler Angiography Parameters between Benign Endometrial Pathologies and Endometrial Cancer

  • Erenel, Hakan;Bese, Tugan;Sal, Veysel;Demirkiran, Fuat;Arvas, Macit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2507-2511
    • /
    • 2016
  • Purpose: To study the diagnostic accuracies of serum human epididymis protein 4 (HE-4) levels, virtual organ computer-aided analysis (VOCAL) parameters and endometrial volume in endometrial cancer cases. Materials and Methods: One hundred and seven patients (37 with endometrial cancer and 70 with benign endometrial pathology) were included in this study. VOCAL parameters and serum HE-4 levels were compared between the groups. Results: Area under the curve (AUC) values were 0.702, 0.658, 0.706 for vascularization index (VI), the flow index (FI) and the vascularization flow index (VFI), respectively. A cut off value of 0.568 for VI demonstrated 70% sensitivity, 72% specificity, 56% positive predictive value (PPV) and a81% negative predictive value (NPV). A cut off value of 25.8 for showed a senitivith of 70% and a specificity of 58% with aPPV of 46% and NPV of 78%, and with a cut off value of 0.12 for VFI 70%, 69%, 54% and 81%, respectively. The area under the curve for HE-4 was 0.814. A cut off value of 458 pmol/L was predictive of malignancy with 86% sensitivity and 63% specificity. Conclusions: VOCAL parameters and serum HE-4 levels were statistically significantly higher in the endometrial cancer patients. Serum HE-4 levels provided a greater sensitivity compared to power doppler angiography for predicting malignancy or benign endometrial pathology.

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

Quantitative Analysis of Silicone Oil in Antifoaming Agent (소포제중 실리콘 오일의 함량에 대한 분석)

  • Kim, Kyeong Sook;Yang, Seug Ran;LIm, Chun Sik;Park, Hyun Joo
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.337-342
    • /
    • 2000
  • Many kinds of experiments were performed for the quality control of antifoaming agents used in thermal power pIants of KEPCO. We tried to establish more convenient ans more accurate quantitative analytical method to determine the amount of silicone oil in silicone oil type antifoaming agent regardless of the amount and/or the type of involved surface active agents. First, the amount of silicone oil was measured by gravimetric method or centrifugal method using very simple apparatus, and then was compared to the results of FT-lR spectroscopy. The centrifugal method was turned out a poor method depending upon the recovery test and virtual experiments. Some antifoaming agents showed very similar results between gravimetric method and spectroscopic methods, and the others gave very different results. We concluded that FT-lR spectroscopy is the most convenient and reliable methodto determine the amounts of silicone oil in the antifoaming agents.

  • PDF

Post-Rendering 3D Warping using Projective Texture (투영 텍스춰를 이용한 렌더링 후 3차원 와핑)

  • Park, Hui-Won;Ihm, In-Seong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.8
    • /
    • pp.431-439
    • /
    • 2002
  • Due to the recent development of graphics hardware, real-time rendering of complex scenes is still a challenging task. As results of researches on image based rendering, the rendering schemes based on post-rendering 3D warping have been proposed. In general, these methods produce good rendering results. However, they are not appropriate for real-time rendering since it is not easy to accelerate the time-consuming algorithms within graphics subsystem. As an attempt to resolve this problem of the post-rendering 3D warping technique, we present a new real-time scheme based on projective texture. In our method, two reference images obtained by rendering complicated objects at two consecutive points of time are used. Rendering images of high quality for intermediate points of time are obtained by projecting the reference images onto a simplified object, and then blending the resulting images. Our technique will be effectively used in developing real-time graphics applications such as 3D games and virtual reality software and so on.

Efficiacy of CT Colonography in the Detection of Colorectal Polypoid Lesions (대장의 폴립양 병변의 발견에 있어 CT 대장조영술의 유용성)

  • Kim, Yun-Gyeong;Lee, Ji-Eun;Lee, Jeong-Gyeong;Baek, Seung-Yeon;Song, Hyeon-Ju;Jeong, Seong-Ae
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.49-59
    • /
    • 2006
  • "본 논문은 대한영상의학회지 2005년 제52권 제1호에 실렸던 논문으로 대한영상의학회의 승인을 득하고 본 협회지에 게재함. Purpose: We wished to compare CT colonography with conventional colonoscopy for the detection of colorectal poiypoid lesions, and we wanted to evaluate the role of IV contrast-enhanced CT colonography for the differentiation between benign polypoid lesions and malignant polypoid lesions. Materials and Methods: Thirty-four consecutive patients underwent CT colonography prior to conventional colonoscopy, Precontrast prone-position CT images and post contrast supine position CT images were obtained and the virtual colonoscopic images were reconstructed, Axial, sagittal and presence, size and morphologic features of colorectal polypoid lesions, and thor these findings were compared with the colonoscopic findings. The degree of enhancement of colorecralpolypoid lesions was measured by subtracting the attenuation valves obtained with precontrastand postcontrast CT images for the differentiation of benignity and malignancy of the colorectal polypoid lesions. Results. Among 75 colorectal polypoid lesions identified on conventional colonoscopy, 49neoplasms were found on CT coloaographv, and the overall detection rate was 65,3%.Detection rate of lesions smaller than l0mm was 52.1%(24/46), and the detection rate for lesions equal to or larger than 10mm was 86.2%(25/29), Morphologic features of the sessile type lesions on CT colonography were well correlated with those noted on colonoscopy, but the stalks were not identified in 6 of 13 polyps on CT colonography. There was no statistical correlation between benignity and malignancy and the degree of contrast enhancement on CT colonography, Conclusion CT colonography is a useful modality for the detection of colorectal polypoid lesionsequal to or polyps. However, CT colonography cannot differentiate benignity from malignancy.

  • PDF

The accuracy of reformatted images using a new virtual 3-dimensional dental implant system (국내에서 개발된 3차원 임플란트 가상시술 시스템에 의한 영상재구성상의 정확도)

  • Choi Jin-Seok;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • Purpose: To compare the measurements of the mandible and the detectability of the mandibular canal on reformatted images using a newly developed 3-dimensional implant simulation program with traditionally used CT multiplanar reconstruction program and true measurements. Materials and Methods: Ten dry dog mandibles were used in this study. Occlusal templates for CT examination were fabricated and marked with gutta perch a at ten sites. Axial CT scans were taken and reconstructed using DentaScan (D group) and Vimplant program (V group), and each mandible was sectioned at the previously marked sites (R group). Maximum vertical height (H) and maximum width (W) of the mandible, the distances from buccal border of the mandibular canal to the most buccal aspect of the mandible (X), and the distance from the superior border of the mandibular canal to the alveolar crest (Y) were measured, and the mandibular measurements in each group were compared. Detectability of mandibular canal was evaluated using a 3-point scale in both V and D groups by three oral radiologists and compared. Results: H in the V group was slightly greater than that in the D group, and Wand X in the V group was slightly less than those in the D group. H in the V group was less than that in the R group, and Wand X in the V group was larger than those in the R group. The detectability of the mandibular canal did not show statistically significant differences between V and D groups. Conclusion: The results of the experiment show that the newly developed, inexpensive Vimplant/TM/ simulation program can be used as an alternative to the traditionally used, and more expensive CT multiplanar reconstruction program.

  • PDF