• Title/Summary/Keyword: ViewRay

검색결과 382건 처리시간 0.034초

Q-Ray View를 이용한 치면열구전색재의 유지상태 평가 (Reliability of Q-Ray View for Assessing Retention Status of Pit and Fissure Sealant)

  • 남상미;구혜민;이은송;김백일
    • 대한치과의사협회지
    • /
    • 제58권3호
    • /
    • pp.140-151
    • /
    • 2020
  • Purpose: To evaluate reliability of Q-ray view (Aiobio Inc,. Seoul, Korea) for assessing retention status of pit and fissure sealants. Methods: Pit and fissure sealants of 58 permanent molars from 15 third-grade students were examined. Posterior teeth with ≥1 pit and fissure sealants applied to the occlusal surface for >6 months were examined. The teeth were examined using traditional visual-tactile assessments and combined Q-ray view. Pit and fissure sealants were evaluated by assessing marginal plaque, marginal discoloration, marginal integrity, retention, and presence of caries. Fleiss kappa and Cohen's kappa values were calculated to compare inter- and intrarater agreements between visual-tactile and combined Q-ray view assessments. Results: Regarding interrater agreement in visual-tactile assessments, K values of Cohen's kappa for marginal plaque, marginal discoloration, and presence of caries were 0.22-0.57, 0.36-0.57, and 0.43-0.61, respectively, and agreements ranged from slight to moderate. When combined with Q-ray view, the values were 0.81-0.89, 0.69-0.88, and 0.80-0.90, respectively, and agreements ranged from substantial to nearly perfect level, indicating statistical significance. Marginal plaque (0.81-0.83), marginal discoloration (0.57-0.89), and presence of caries (0.69-0.91) showed higher agreements in combined Q-ray view than in visual-tactile assessments, and kappa values of marginal plaques were significantly higher in combined Q-ray view than in visual-tactile assessments. Conclusion: Evaluating retention status of pit and fissure sealants using Q-ray view showed higher reliability than using visual/tactile assessments for marginal plaque, marginal discoloration, and presence of caries. Therefore, Q-ray view may be used to assess the retention status of pit and fissure sealants.

  • PDF

Q-Ray View 활용이 치위생과정을 위한 치아 검사의 신뢰도 향상에 미치는 영향 (The Effects of the Q-Ray View on Reliability of Assessing a Tooth Status for Dental Hygiene Process)

  • 오혜영;정회인;구혜민;김백일
    • 치위생과학회지
    • /
    • 제14권4호
    • /
    • pp.461-467
    • /
    • 2014
  • 본 연구는 치위생과 대학에서 이루어지고 있는 치위생과정 실습에서 3학년 학생들이 대상자의 치아상태를 Q-ray view를 사용하지 않고 평가한 방법과 Q-ray view를 사용하여 평가한 방법을 숙련된 검사자의 치아검사결과를 기준치로 하여 부위별, 병소 및 수복물별 일치도를 비교하였다. 부위별 차이에서 병소와 수복물은 Q-ray view를 사용한 경우에 높은 일치도를 나타냈다. 특히 상악전치부는 수복물에서 100% 정답기준과 일치하였다. 병소 및 수복물별 차이에서 Q-ray view를 사용한 경우 병소에서는 치아우식증과 초기우식증, 치아파절에서 차이가 있었고 수복물에서는 수복물 또는 치면열구전색이 없는 경우와 심미수복물에서 유의한 차이가 있었다. 본 연구의 결과 Q-ray view를 병행해서 치아검사를 수행했을 때 경험이 부족한 치위생과 학생의 치아검사 신뢰성이 향상되었다. 따라서 치위생과정 실습에서 Q-ray view는 학생의 치아검사역량 증진에 효과적인 도구로 활용될 수 있을 것이다.

Q-ray view를 이용한 유구치의 숨은 인접면 우식증 탐지 (Detection of Hidden Proximal Caries using Q-ray view in Primary Molars)

  • 정연욱;이효설;최형준;이제호;최병재;김성오
    • 대한소아치과학회지
    • /
    • 제42권3호
    • /
    • pp.209-217
    • /
    • 2015
  • 본 연구는 Q-ray view (All in one Bio, Seoul, Korea)가 변연융선이 파괴되지 않은 유구치의 인접면 우식증을 적절히 탐지해 낼 수 있는지 알아보고자 하였다. 두 명의 소아치과의사가 3-9세 사이의 어린이 32명(평균연령 $5.6{\pm}1.3$세)의 유구치 인접면 100개를 시진, Q-ray view, DIAGNOdent (KaVo, Biberach, Germany), 디지털 치근단 방사선사진 촬영으로 평가하였다. 각 검사법과 실제 치료 시 관찰된 인접면 우식증의 진행 정도를 비교하였을 때, 법랑질 우식증에 대한 kappa값은 시진, Q-ray view, DIAGNOdent, 디지털 치근단 방사선사진 촬영 순으로 0.15, 0.10, 0.25, 0.68이었으며, 상아질 우식증에 대한 kappa값은 0.34, 0.56, 0.44, 0.70이었다. Q-ray view는 상아질까지 진행된 유구치의 숨은 인접면 우식증을 탐지하는 데 도움을 줄 수 있는 유용하고 간편한 보조장비가 될 수 있을 것으로 기대된다.

MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가 (Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment)

  • 선거준;손상준;이양훈;이제희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.169-176
    • /
    • 2018
  • 목 적 : Bolus 적용 유, 무와 치료기에 따른 피부 선량을 측정, 비교하여 Malignant Fungating Wound와 같이 높은 피부 선량을 요구하는 경우 피부 선량 증가 목적으로 Co-60 ViewRay 치료계획의 임상 적용 가능성을 검토하였다. 대상 및 방법 : 표면선량을 측정하기 위해 Rando phantom을 이용하여 좌측유방 중심부를 기준으로 2.5 cm 격자 배열의 9개의 내측 측정지점과, 유방과 피부와 접하는 상하, 좌우 4개의 외측 측정지점을 포함한 총 13개 측정지점을 표시하였다. CT를 촬영을 하여 Eclipse와 ViewRay-TPS를 통해 각각의 치료계획을 수립하였으며, 좌측유방 V2Gy = 95 %가 전달되도록 Fixed beam-IMRT 치료계획을 수립하였다. 측정 전 QED 검출기를 교정하였으며 Phantom에 표시된 13개의 측정지점에 QED 검출기를 위치시켜 각 치료계획 별 표면선량을 True-beam과 View-ray를 이용하여 5 mm Bolus 적용 전과 후, 각각 3회 측정하여 비교하였다. 결 과 : 5 mm Bolus를 적용 전 Co-60 Viewray와 선형가속기의 표면선량은 $76.8%{\pm}5.2%$ vs. $67.3%{\pm}7.5%$로 나타났으며, 5 mm Bolus 적용 후 표면선량은 각각 $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$로 측정되었다(p<0.001). 결 론 : 각 치료기의 표면선량 측정결과, Co-60 ViewRay는 Bolus를 사용하지 않았음에도 불구하고 표면 선량이 일반 5 mm Bolus를 사용한 6 MV 선형가속기의 95.6 % 수준 달하는 것을 확인하였다(p<0.001). 또한 매 회 치료마다 자기공명영상을 이용하여 피폭 문제없이 치료 부위 변화를 관찰할 수 있어 적응형 치료계획을 수립하기 쉽고 피부 선량 확보가 수월하므로, 크기 변화가 빠르고 높은 피부선량을 요구하는 Malignant Fungating Wound 환자의 경우 Co-60 ViewRay가 선형가속기에 비해 유용할 것으로 사료된다.

  • PDF

다시점 X선 영상을 이용한 3차원 좌표 획득 (3D Coordinates Acquisition by using Multi-view X-ray Images)

  • 이수영;이재영;김순철;이정규
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

양면 PCB의 납땜부 검사를 위한 새로운 X선 단층영상 시스템 (A new X-ray cross-sectional image system for solder joint inspection of double-sided PCB)

  • 강성택;정재훈;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.117-120
    • /
    • 1996
  • In this paper, a new approach to acquire the cross-sentional image for automatic solder joint inspection of double-sided PCB using X-ray source is presented. We designed the apparatus with fixed X-ray source to realize the cross-sectional image by tunning object and detector synchronously. The cross-sectional images are captured at several view angle of X-ray source, the geometric image distortions caused by view angle and the shape of image intensifier are compensated. The precision variation of cross-sectional image by the change of view angle was investigated. Also we acquired the cross-sectional image to the solder joint of double-sided PCB and reconstructed the shape of solder joint.

  • PDF

요추 단순 방사선 검사와 체형분석 기기를 통한 변위진단과 상관관계 분석 (Correlation Analysis about Subluxation Diagnosis Using Lumbar X-ray and Body Shape Analysis System)

  • 이지원;주민수;고연석;임이건;황현호
    • 한방재활의학과학회지
    • /
    • 제33권4호
    • /
    • pp.195-201
    • /
    • 2023
  • Objectives This study analyzed the correlation between lumbar spine and pelvic body parameters measured using body shape analysis system and X-ray view. Methods Body shape analysis system and X-ray view were performed for 100 patients to diagnose subluxation using body parameters such as pelvic obliquity angle, anterior superior iliac spine to posterior superior iliac spine angle (ASIS-PSIS angle), lumbar lateral flexion angle. The correlation analysis using body parameters obtained through the body shape analysis system and X-ray view was performed by measuring the Pearson correlation coefficient, a parameter test. Results Significant correlations were observed between the values for pelvic obliquity angle, ASIS-PSIS angle, lumbar lateral flexion angle measured by X-ray view and body shape analysis system. The most significant correlation was observed in the value of pelvic obliquity angle. Conclusions Body parameters and posture analysis measured by the body shape analysis system can be used in place of X-ray view. Additional research and samples are still necessary.

CT의 선량 감소를 위한 sinogram 보간 기법 (A Method for Sinogram Interpolation for Reducing X-ray Dose)

  • 김재민;이기승
    • 한국통신학회논문지
    • /
    • 제37권7C호
    • /
    • pp.601-609
    • /
    • 2012
  • 본 논문에서는 전산화 단층촬영 시 스캔 시간의 단축 및 환자의 X-Ray 피폭량을 줄이기 위한 방법으로 샘플링 빈도를 줄이고 적은 수의 view를 이용하여 단면 영상을 재구성하는 방법에 대해 연구하였다. 부족한 view로 인해 단면 영상에 발생하는 방사형의 직선형 왜곡(streak artifact) 를 억제하기 위하여 본 논문에서는 sinogram 보간기법을 적용하였다. 인접 view간 영상 특성(밝기, 그라디언트, 픽셀거리)을 기반으로 sinogram 픽셀 간의 매칭을 수행하고 그 결과를 기반으로 변화패턴을 추적하여 sinogram을 보간하도록 하였다. Numerical 팬텀과 자체 제작된 팬텀을 이용하여 제안된 기법을 검증하였다. 선형 보간 기법에 비해 재구성된 단면영상의 디테일을 유지하면서 왜곡이 감소하는 것이 관찰되었으며, PSNR면에서 최대 5%의 향상이 있는 것을 확인하였다.

인체 두부에서 Dynamic Tomogram의 응용에 관한 연구 (A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD)

  • 최의환;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF

Barge 방식에 의한 요추부 척추측만증과 추간판 탈출증의 X-ray 비교분석 (The Comparative analysis of X-ray film on Lumbar Scoliosis and HNP by Barge Method)

  • 김규섭
    • 척추신경추나의학회지
    • /
    • 제6권1호
    • /
    • pp.53-61
    • /
    • 2011
  • Objective: The purpose of this study is to evaluate the disc block subluxation for lumbar scoliosis and herniation of nucleus pulpous (HNP). Methods: We used AP & Lateral view X-ray for patients. And we measured of disc wedge angle, vertebral body rotation to evaluate the typical and atypical disc block subluxation. Results: On the analysis of the lateral view X-ray, 4th lumbar intervertebral disc angle (I.V.D angle) showed $4^{\circ}$, $5^{\circ}$, $3^{\circ}$, $0^{\circ}$ in the cases. On the 4th lumbar analysis of the AP view X-ray, lumbar scoliosis showed right disc wedge angle was $11^{\circ}$ (case 1), $17^{\circ}$ (case 2) and left vertebral body rotation was 13mm, 6mm. Lumbar HNP showed left disc wedge angle was $5^{\circ}$ (case 3), $4^{\circ}$ (case 4) and left vertebral body rotation was 2mm, 4mm. Conclusions: Disc block subluxation has been in lumbar scoliosis, but not been in lumbar HNP.

  • PDF