• Title/Summary/Keyword: View Axis

Search Result 350, Processing Time 0.033 seconds

Echocardiograpyhic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog III. Detection of Heartworm (진돗개에서 심장초음파 측정치와 평가와 임상적 응용)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.194-204
    • /
    • 2000
  • Echocardiography was performed to obtain the optimal planes for diagnosis of canine heartworm disease in 11 dogs. Imaging planes were taken the left ventricular outflow tract long-axis view, 4-chamber long-axis view, chordae tendineae level short-axis view and modified pulmonary arteries level short-axis view in the right parasternal window, and aptical 4-chamber long-axis view in hte left parasternal window. After echocaridography, the pulmonary artery valve pat was ligated with double 1-0 silk under the general anesthesia to prevent heartworm moving from pulmonary artery to right ventricle. The dogs were euthanized and examained for heartworms in heart and great vessels. Many adult heartworms were identified ultrasonographically within main pulmonary artery, bifurcation of pulmonary artery and right pulmonary artery, but not identified within right ventricle and atrium. At necropsy, adult heartworms were mainly found in pulmonary artery in 11 days, and also found in right ventricular outflow tract and right ventricle in 2 of 11 dogs. The modified pulmonary arteries level short-axis view was the best imaging plane for identifiying heartworms because the main pulmonary artery, branches of pulmonary artery and right pulmonary artery could be showed. The aortic root internal dimension (AOID) and right pulmonary atery internal dimension (RPAID) were measured from the modified pulmonary ateries level short-axis view and left ventricular outflow tract long-axis view. The RPAID and RPAID/AOID was higher in heartworm infected dogs than normal Korea Jin-do dogs in modified pulmonary arteries level short-axis view, and the AOID, RPAID and RPIAID/AOID was higher than in left ventricular outflow tract long-axis view, respectively. These results indicate that the pulmonary arteries were the major habitat of adult heartworm in canine heartworm disease and the modified pulmonary arteries level short-axis view was the best imaging planes for identifying heartworms because the main pulmonary arteries could be showed. Therefore the modified pulmonary arteries level short-axis view can be used for diagnosing heartworm disease and for monitoring dilation of pulmonary artery.

  • PDF

Optimal Motion Control of 3-axis SCARA Robot Using a Finite Jerk and Gain Tuning Based on $LabVIEW^{(R)}$ ($LabVIEW^{(R)}$ 기반 3축 스카라 로봇의 유한 저크 및 게인 동조를 이용한 최적 모션 제어)

  • Kim, J.H.;Chung, W.J.;Kim, H.G.;Lee, G.S.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.40-46
    • /
    • 2008
  • This paper presents the optimal motion control for 3-axis SCARA robot by using $LabVIEW^{(R)}$. Specifically, for optimal motion control of 3-axis SCARA robot, we study velocity profile based on finite jerk(the first derivative of acceleration) and optimal gain tunig based on frequency response method by using $LabVIEW^{(R)}$. The velocity optimization with finite jerk aims at generating the smooth velocity profile of robot. Velocity profile based on finite jerk is acquired and applied to 3-axis SCARA robot by using $LabVIEW^{(R)}$. DSA(Dynamic Signal Analyzer) for frequency response method is programed by using $LabVIEW^{(R)}$. We obtain the bode plot of transfer function about 3-axis SCARA robot by using DSA, and perform the gain tuning considering dynamic characteristic based on the bode plot. These experiments have shown that the proposed motion control can reduce vibration displacement and response error rate each 33.7% and 51.7% of 3-axis SCARA robot.

The Echocardiographic Assessment and clinical Application of Cardiac Disease in Korean Jin-do dog (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 I. 심장초음파 측정치)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.178-186
    • /
    • 2000
  • Echocardiography was performed on 29 normal Korea Jin-do dogs(21 adults and 8 prematures) and the images were taken from chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view, respectively. The following cardiac parameters, in systole and diastole, were measured on the echoocardographic images: aortic dimension(AO), left atrial dimension(LA), left ventricular internal dimention at end-diastole (LVIDd), left ventricular internal dimention at end-systole(LVIDs), interventricular septal wall thickness at end-diastole(IVSd), interventricular septal wall thickness at end-systole(IVSs), left ventricular wall at end-diastole(LVWd), left ventricular wall at end-systole(LVWs). The cardiac parameters were not significantly different between sex and among imaging planes. The size of cardiac parameters increaed as regression lines according to body weights. These results suggest that the chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view can be utilized for the left cardiac examination, and these cardiac parameters can be used to basic dat for diagnosing the cardiac diseases in Korea Jin-do dog.

  • PDF

Technique for Simulating Gain Tuning using SolidWorks® and LabVIEW® for a Six-Axis Articulated Robot (SolidWorks®와 LabVIEW®를 연동한 6축 수직 다관절 로봇의 게인 튜닝 연구)

  • Jung, C.D.;Chung, W.J.;Kim, M.S.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.75-82
    • /
    • 2014
  • For accurate gain tuning of the lab-manufactured six-axis articulated robot RS2 with less noise, in this study, a program routine using dynamic signal analyzer, which is a realization of a controller design algorithm in the frequency domain, is programmed using LabVIEW$^{(R)}$. The contribution of this paper is the proposal of a simulation technique based on SolidWorks$^{(R)}$ and LabVIEW$^{(R)}$ for the gain tuning of a six-axis articulated robot. To realize the simulation, the LabVIEW$^{(R)}$ program used for experimental gain tuning is incorporated in to SolidWorks$^{(R)}$. A comparison shows that the results of simulation-based gain tuning and experimental gain tuning are almost the same within a 5% error bound. On the basis of the comparison, it can be suggested that the simulation-based technique for gain tuning can be applied instead of experimental gain tuning to a six-axis articulated robot by interlocking SolidWorks$^{(R)}$ and LabVIEW$^{(R)}$.

Radiographic Analysis of Tibial-Articular Surface Angle According to the Selection of the Mechanical Axis (역학적 축 선정에 따른 전후면 경골천장각의 단순방사선학적 분석)

  • Park, Jin-Sung;Jeong, Soon-Taek;Hwang, Sun-Chul;Kim, Dong-Hee;Gwark, Ji-Yong;Yoon, Hong-Kwon;Nam, Dae-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2013
  • Purpose: We investigated a statistical difference of tibial-articular surface (TAS) angles between radiographs of standing ankle anteroposterior (AP) and whole lower extremity view, and evaluated whether the tibial axis obtained from the standing ankle AP view reflects the original mechanical axis of lower extremity. Materials and Methods: Both the standing ankle AP and whole lower extremity view were taken from 60 legs of 30 healthy volunteers without a history of ankle surgery or deformity of lower limb. To determine the tibial axis, Takakura's and Hintermann's method were employed in the standing ankle AP view. To compare these results with the original TAS angle, ANOVA and multiple comparison test were used. Results: The mean TAS angle was 88.3 degrees(from hip joint to ankle), 89.5 degrees (from knee joint to ankle), 88.5 degrees (Takakura's method), and 90.2 degrees(Hintermann's method). Although there was a statistical significance (p=0.000) between these results, Takakura's method had no significant difference, compared to the results of whole extremity view by the multiple comparison test. Conclusion: The tibial axis obtained by Takakura's method reflects the original mechanical axis of lower extremity. When a surgical procedure is planned, however, it is necessary to consider that the ankle radiographs do not provide any information on the proximal deformity without the whole lower extremity view.

The Echocardiographic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog II. Comparison of Aortic Root Internal Dimension with Right Pulmonary Artery Internal Dimension (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 II. 대동맥기부내경과 우페동맥내경의 비교)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.187-193
    • /
    • 2000
  • Fifteen adult Korea Jin-do dogs were studied by echocardiography to obtain the basic data of the imaging planes and normal references ranges to the aorta and pulmonary artery internal dimension. Measurements of aortic root internal dimension(AOID) and right pulmonary artery internal dimension (RPAID) were made at modified pulmonary arteries level short-axis view and left ventricular outflow tract long-axis view. The aortic root internal dimension and right pulmonary artery internal dimension at modified pulmonary arteries level short-axis view were 18.7$\pm$1.3mm (mean$\pm$SD) and 10.1$\pm$0.8mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. The aortic root internal dimension and right pulmonary artery internal dimension at left ventricular outflow tract long-axis view were 19.3$\pm$1.6 mm and 10.7$\pm$1.3mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. These results indicate that modified pulmonary arteries level short-axis view is useful planes to examine the aortic root and pulmonary arteries, and aortic root internal dimension is significantly higher(40~50%)than the right pulmonary artery internal dimension. Therefore measurements of aortic root internal and right pulmonary artery internal dimension can be used for monitoring dilation of pulmonary artery.

  • PDF

Evaluation of mesiodistal tooth axis using a CBCT-generated panoramic view (CBCT-재구성 파노라마영상의 근원심 치축에 관한 연구)

  • Song, In-Tae;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.255-267
    • /
    • 2011
  • Objective: The purpose of this study was to confirm the reliability of a cone beam computed tomography (CBCT)-generated panoramic view based on a CBCT 3D image and to find the most helpful 2D panoramic image compared with CBCT 3D image when examining the mesiodistal tooth axis. Methods: A test model was constructed according to cephalometric norms. The test model was repeatedly repositioned for CBCT and panoramic radiographic imaging. Panoramic radiographs were acquired at each of the following 3 occlusal plane positions: $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$. Measurements of mesiodistal tooth axis in CBCT 3D image, CBCT-generated panoramic view, and panoramic radiographs were compared. Results: Compared with the CBCT-generated panoramic view, CBCT 3D image showed significant difference in the mesiodistal tooth axis in the premolars and no significant difference in the mesiodistal tooth axis in the incisors and canines. Mesiodistal tooth axis on the CBCT-generated panoramic view was significantly different from that on panoramic radiographs. Conclusions: CBCT-generated panoramic view can be a useful tool for evaluating mesiodistal tooth axis.