• Title/Summary/Keyword: View Angle

Search Result 798, Processing Time 0.036 seconds

Intermediate Image Generation of Stereo Image Using Depth Information and Block-based Matching Method (깊이정보와 블록기반매칭을 이용한 스테레오 영상의 중간영상 생성)

  • 양광원;허경무;김장기
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.10
    • /
    • pp.874-880
    • /
    • 2002
  • A number of techniques have been proposed for 3D display using view-difference of two eyes. These methods do not express enough reality like real world. The display images have to change according to the position of a viewer to improve reality. In this paper, we present an approach for generating intermediate image between two different view images by applying new image interpolation algorithm The interpolation algorithm is designed to cope with complex shapes. The proposed image interpolation algorithm generates rotated image about vertical axes by any angle from base images. Each base image that was obtained from CCD camera has an view-angle difference of $3^{\circ}C$, $5.5^{\circ}C$, $^{\circ}C$, $22^{\circ}C$, and $45^{\circ}C$. The proposed into mediate image generation method uses the geometric analysis of image and depth information through the block-based matching method.

전 시야각영역에서 시야각 조절이 가능한 액정 디스플레이

  • Heo, Jeong-Hwa;Kim, Jin-Ho;Im, Yeong-Jin;Park, Gyeong-Ho;Lee, Jeong-Ho;Kim, Yeong-Gu;Lee, Seung-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.163-163
    • /
    • 2009
  • Viewing angle controllable liquid crystal display (LCD) associated with fringe-field switching (FFS) mode with high image quality is proposed. In the device, one pixel is composed of main and sub pixels, in which adjacent sub pixel is patterned with pixel electrodes direction orthogonal to the adjacent one. In this way, light leakage can be generated in the all viewing angle directions except the normal direction, realizing view angle controllable LCD in both horizontal and vertical directions.

  • PDF

A Study of viewing angle characteristics of the film compensated TN mode

  • Park, Chi-Hyuck;Kim, Eui-Man;Lee, Jang-Ho;Park, Cheol-Woo;Lee, Kyung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1462-1465
    • /
    • 2009
  • Because of its weak points that narrow viewing angle and grayscale inversion, 'bare' twisted nematic (TN) LCD has some limits to use as a display device, though its great strong points that low cost, high yield, simple design, high transmittance and normally white. The 'WideView(WV)' film which introduced by Fuji co., has been good solution to extend the viewing angles of TN mode, therefore that film have been used generally for TN panels needed wide viewing angle. This paper introduce the research to find the parameters of the Wide view film and a TN panel which affect viewing angle characteristics and how to adjust those parameters.

  • PDF

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging (자기공명영상을 이용한 금속전극의 정확한 위치 결정)

  • Joe, Eun-Hae;Ghim, Min-Oh;Ha, Yoon;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2011
  • Purpose : Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. Materials and Methods : Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional ($90^{\circ}$ view) and $45^{\circ}$ oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. Results : There was least field inhomogeneity along the $45^{\circ}$ line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with $45^{\circ}$ oblique-view was coincided regardless of susceptibility. And with $45^{\circ}$ oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the $45^{\circ}$ oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. Conclusion : We suggested the method for accurate localization of electrode using $45^{\circ}$ oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery.

Radiological Analysis of the Degenerative Arthritis of the Ankle (족관절 퇴행성 관절염의 방사선학적 분석)

  • Lee, Woo-Chun;Kang, Yeong-Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.135-139
    • /
    • 2005
  • Purpose: This study was performed to investigate the radiological characteristics of the degenerative arthritis of the ankle using the standing radiographs. Materials and Methods: From June 2001 to May 2005, 36 patients (56 ankles) who were treated for osteoarthritis of ankle were analysed. Angle of tibial shaft and tibial joint surface on AP view (TSA), angle of tibial joint surface on lateral view (TLS), tibial and medial malleolus angle (TMM) and talo-1st metatarsal angle were checked on standing radiograph. The patients with medial joint and total joint involvement were categorized into three stages according to the location of involvement. The degree of joint space narrowing was categorized into two groups. Results: There were no significant differences in TSA, TLS, TMM and talo-1st metatarsal angle with regard to the stage of arthritis. However, the difference between the less severe group and the severe group existed. Conclusion: Angular deformity was not correlated with stage, but correlated with severity. The deformity of distal tibial articular surface does not seem to be a cause of primary osteoartiritis, but rather a result from it.

  • PDF

Predicting Factors on Ankle Stability - Mortise Angle and Fibular Length - (족관절 안정성의 예상인자 -격자각과 비골의 길이-)

  • Lee, Sang-Wook;Koh, Sang-Bong;Shin, Min-Cheul;Lee, Byoung-Kwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2004
  • Purpose: The aim of this study was to investigate the usefulness of mortise angle and fibular length measured in radiologic findings in predicting the ankle stability. Materials and Methods: One hundred cases fifty cases were randomly selected volunteers with normal ankle function and the other fifty cases were randomly selected patients whose ankle were treated in our hospital and who were followed for over 1 years with good results. A specific experimental fixture were made to get the even AP and lateral view and objective stress view. Results: The mortise angle and fibular length was not statistically significant to the degree of talar tilt angle under valgus or varus stress and that of displacement under anterior or posterior stress. Conclusion: The mortise angle and fibular length was not the objective predicting factors on the ankle stability. Maintenance of constrained talus in dynamic status is most important factors in determining the ankle stability.

  • PDF

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs (LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Design of Off-axis Wide Angle Lens for the Automobile Application

  • Kim, Tae Young;Shin, Min-Ho;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.336-343
    • /
    • 2013
  • Recently various types of driver assistance systems have been used for automobiles. In 2008, the U.S Congress passed a law which required that most cars be equipped with devices to warn objects behind the vehicle. Because of that, market of rear view cameras is expected to rise dramatically. Therefore many suppliers try to provide a wide angle camera for car makers. But a high distortion is caused by the wide angle might result in lower image quality. In order to improve the image quality, normally we use an algorithm to correct a distortion. Though we can improve the distorted image by correction algorithm, we must pay more cost to use it. In this paper, we propose a new optical system reducing a distortion in contrast to a conventional lens without cost. In other words, we can see only an area of interest. That is similar to reducing a field of view. Using a new optical system, we can get a less distorted image. In order to view an area of interest, we introduce an off axis optical system having refractive surfaces and reflective surfaces. In this paper, we describe the results of design and, evaluation of an off axis wide angle compact imaging system. In comparison to conventional wide angle lens, we can get the improvement of MTF, distortion, and lateral color aberrations. And we also can reduce a total cost because we don't need the outer apparatus or bracket to mount on the car.