• Title/Summary/Keyword: Video Rate

Search Result 1,823, Processing Time 0.032 seconds

Effect of washing methods on the quality of freshly cut sliced Deodeok (Codonopsis lanceolata) during storage (세척방법에 따른 신선편이 슬라이스 더덕의 저장 중 품질 특성 변화)

  • Choi, Duck-Joo;Lee, Yun-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Cha, Hwan-Soo;Youn, Aye-Ree
    • Food Science and Preservation
    • /
    • v.20 no.6
    • /
    • pp.751-759
    • /
    • 2013
  • There is increasing interest in freshly cut products, that is, foods produced without washing and cutting. In this study, the quality of freshly cut sliced Deodeok was compared with that of what based on its washing methods. In bubble washing, the Deodeok rises to the water surface apace and is broken into centimeter sizes. Microbubble washing calls for the production of a great number of 0.1 mm-sized bubbles in anions-bearing water and their passing through a trumpet-shaped hole at a high pressure. To compare the product deterioration rates of the specimens, they were stored at $10^{\circ}C$ for 10 days. In the specimens washed with the control method and with hand washing, the deterioration rate was 80%; and in the specimens washed with bubble and microbubble washing, 20~30%. The L-value (an index of browning) was higher in the bubble and microbubble washing than in the control and the hand washing, which implies that browning was minimized during the storage. As for the viable cell and coliform group counts that were measured during the storage, the specimens washed with the control method showed the highest values. In contrast, the specimens washed with microbubble washing showed the lowest values. In the sensory test, the specimens washed with microbubble were highest in storage preference. In conclusion, the Deodeok that was stored after it was washed with microbubble washing was found to have had the best quality.

Actual Status of and Measure for False Alarm of Electronic Security in Korea (한국 기계경비업무의 오경보 대응책)

  • Park, Dong-Kyun;Kim, Tae-Min
    • Korean Security Journal
    • /
    • no.30
    • /
    • pp.33-60
    • /
    • 2012
  • False alarm of Electronic security causes various serious side effects such as decrease of electronic security guard's morale caused by unnecessary mobilization, increase of fatigue caused by workload increase, increase of electronic security company owner's management burden and decrease of electronic security service utilization rate caused by customer's distrust. Therefore, the study considered the Korean regulation related with false alarm of electronic security and proposed actual status of false alarm and measure for it. The study proposed systematic resolution assignments and political assignments in relation with the measure for false alarm. Systematic resolution assignments are as follows. First, electronic security company should construct electronic security system accurately from the initial step of security consulting and security planning related with target facility. Second, it is necessary to encourage installation and operation of video monitoring system. Third, sensor wiring should be separated. Fourth, the measures for false alarm depending on main system causes should be prepared. It is necessary to encourage the installation of 'arming disarming alarm sound' generator. In addition, the measures for false arm depending on the characteristics of sensor should be prepared and standardized. Fifth, system maintenance should be reinforced. Political assignments related with the measures for false alarm are as follows. First, it is necessary to reinforce education & training. Individual nurturing & education process should be run by electronic security company or the education focusing on the measure for false alarm should be performed in job training defined in "Security Industry Act". Second, it is necessary to establish and reinforce legal regulation and establish device. If police authority standardizes the documents related with false alarm, provides their forms and requires them for periodical reports or documents, it is expected that good measures for false alarm will be prepared on the basis of actual data in the future. Third, cooperation organization to discuss the measures for false alarm like 'Conference for False Alarm of Electronic Security' should be organized and operated. Fourth, interest and role of electronic security company and electronic security supervisor should be enlarged.

  • PDF

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

A 10b 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS Pipeline ADC for HDTV Applications (HDTV 응용을 위한 10비트 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS 파이프라인 A/D 변환기)

  • Park, Beom-Soo;Kim, Young-Ju;Park, Seung-Jae;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.60-68
    • /
    • 2009
  • This work proposes a 10b 200MS/s 65nm CMOS ADC for high-definition video systems such as HDTV requiring high resolution and fast operating speed simultaneously. The proposed ADC employs a four-step pipeline architecture to minimize power consumption and chip area. The input SHA based on four capacitors reduces the output signal range from $1.4V_{p-p}$ to $1.0V_{p-p}$ considering high input signal levels at a low supply voltage of 1.2V. The proposed three-stage amplifiers in the input SHA and MDAC1 overcome the low output resistance problem as commonly observed in a 65nm CMOS process. The proposed multipath frequency-compensation technique enables the conventional RNMC based three-stage amplifiers to achieve a stable operation at a high sampling rate of 200MS/s. The conventional switched-bias power-reduction technique in the sub-ranging flash ADCs further reduces power consumption while the reference generator integrated on chip with optional off-chip reference voltages allows versatile system a locations. The prototype ADC in a 65nm CMOS technology demonstrates a measured DNL and INL within 0.19LSB and 0.61LSB, respectively. The ADC shows a maximum SNDR of 54.BdB and 52.4dB and a maximum SFDR of 72.9dB and 64.8dB at 150MS/S and 200MS/s, respectively. The proposed ADC occupies an active die area of $0.76mm^2$ and consumes 75.6mW at a 1.2V supply voltage.

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Comparison of VATS with Thoracotomy for the Treatment of Spontaneous Pneumothorax (자발성 기흉의 치료에서의 비디오 흉강경 수술과 개흉술의 비교)

  • 김문수;김영태;김기봉;김원곤;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.294-298
    • /
    • 1999
  • Background: Video-assisted thoracoscopic surgery(VATS) has been established as a new method for treatment of spontaneous pneumothorax. We compared the clinical results of VATS with those of thoracotomy performed during the recent 5 years. Material and Method: We analyzed 126 patients whose medical records were available among the 154 patients who underwent operations for spontaneous pneumothorax from 1992 to 1996. The mean age was 27.1 years(15 to 75 years). 87 patients were operated on by VATS(Group A) and the other 39 by thoracotomy(Group B). The mean follow-up period was 14.7 months. Result: The operation time was shorter in group A than in group B(90.6${\pm}$38.6minutes: 117.2${\pm}$58.9minutes, p<0.05). The duration of postoperative hospital stay was shorter in group A than in group B(6.7${\pm}$4.2: 9.4${\pm}$3.3 days, p<0.05). The amount of analgesics(nalbuphin HCl, ketoprofen) used postoperatively were 2.4${\pm}$2.8 ampules in group A, which is less than the 6.5${\pm}$5.6 ampules in group B(p<0.05). The number of staples used in group A was smaller(2.7${\pm}$1.3 in group A, 1.76${\pm}$1.1 in group B, p<0.05). The duration of chest tube indwelling(4.3${\pm}$4.0 days in group A, and 5.6${\pm}$3.0 days in group B, NS), the recurrence rate(13.8% in group A, 2.6% in group B, NS), and the duration of air leakage(1.3${\pm}$3.3 days in group A, and 1.0${\pm}$2.5days in group B, NS) were not statistically different between the two groups. Conclusion: The application of VATS for the treatment of spontaneous pneumothorax has brought in better clinical results(shorter operation time, shorter hospital stay, less pain, and better cosmetic merits) than the thoracotomy without increasing any morbidity. However no advantages in recurrence rates and duration of postoperative air leakages are revealed.

  • PDF

The Prevalence and Characteristics of Positional Obstructive Sleep Apnea

  • Kim, Cheon-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Lee, Sang-Ahm
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.52-58
    • /
    • 2012
  • Patients with obstructive sleep apnea (OSA) often have more aggravated symptoms in the supine position. We tried to investigate the clinical characteristics and the predictive factors for positional OSA. Polysomnographic data were reviewed for OSA patients (apnea hypopnea index, $AHI{\geq}5$) from April, 2008 to April, 2011 at the Asan Medical Center. Clinical data, comorbid medical condition data and questionnaires (SF-36, MFI-20, ESS, BDI, STAI) were assessed. All patients were classified into two groups: positional patients (PP) group and non-positional patients (NPP) group. PP was defined as a patient who had the AHI in the supine position was at least twice as high as that in the lateral position. The body position of patients was confirmed by sleep position sensor and video monitor. All patients had at least 30 minutes of positional and 30 minutes of non-positional sleep. We compared clinical, medical, polysomnographic data, and questionnaire results between two (PP and NPP) groups and investigated predictive factors for the PP group using binary logistic regression analysis. In total, 371 patients were investigated. 265 (71.4%) was categorized as PP group and 106 (28.5%) as NPP group. The mean age ($mean{\pm}SD$) was higher in the PP group ($52.4{\pm}9.8$) than in the NPP group ($49.5{\pm}11.9$) (p<0.05). Comparison of sleep parameters between the PP and the NPP group showed that the PP group had significantly lower BMI (PP: $26.1{\pm}3.2kg/m^2$; NPP: $27.8{\pm}4.3kg/m^2$, p<0.001), neck circumference (PP: $39.7{\pm}2.8cm$; NPP: $41.5{\pm}3.7cm$, p<0.001) and hypertension rate (PP: n=89/265 (33.5%); NPP: n=48/106 (45.2%), p=0.0240). In the PP group, the percentage of deep sleep (PP: $8.7{\pm}8.1%$; NPP: $5.6{\pm}7.0%$, P=0.001) and rapid eye movement (REM) (PP: $17.5{\pm}6.1%$; NPP: $14.0{\pm}6.9%$, p<0.001) were significantly higher whereas the percentage of light sleep (stage N1) was significantly lower than the NPP group (PP: $30.4{\pm}12.3$; NPP: $44.5{\pm}20.8%$, p<0.001). During the sleep, the AHI in the supine position (PP: $48.6{\pm}19.5$; NPP: $60.5{\pm}22.6$, p<0.001) and in the non-supine position (PP: $9.4{\pm}8.9$; NPP: $48.4{\pm}24.8$, p=<0.001) were significantly lower and the minimal arterial oxygen saturation in non-REM sleep was significantly higher in the PP group (PP: $80.3{\pm}7.6$; NPP: $75.1{\pm}9.9$, p=<0.001). There were no significant differences in all questionnaires including quality of life. The results of the binary logistic regression analysis showed that age, the amount of REM sleep(%) and AHI were significant predictive factors for positional OSA. The significant predictive factors for positional OSA were older age, higher percentage of REM and lower AHI. The questionnaire results were not significantly different between the two groups.

  • PDF

The National Survey of Open Lung Biopsy and Thoracoscopic Lung Biopsy in Korea (개흉 및 흉강경항폐생검의 전국실태조사)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.5-19
    • /
    • 1998
  • Introduction: Direct histologic and bacteriologic examination of a representative specimen of lung tissue is the only certain method of providing an accurate diagnosis in various pulmonary diseases including diffuse pulmonary diseases. The purpose of national survey was to define the indication, incidence, effectiveness, safety and complication of open and thoracoscopic lung biopsy in korea. Methods: A multicenter registry of 37 university or general hospitals equipped more than 400 patient's bed were retrospectively collected and analyzed for 3 years from the January 1994 to December 1996 using the same registry protocol. Results: 1) There were 511 cases from the 37 hospitals during 3 years. The mean age was 50.2 years(${\pm}15.1$ years) and men was more prevalent than women(54.9% vs 45.9%). 2) The open lung biopsy was performed in 313 cases(62%) and thoracoscopic lung biopsy was performed in 192 cases(38%). The incidence of lung biopsy was more higher in diffuse lung disease(305 cases, 59.7%) than in localized lung disease(206 cases, 40.3%) 3) The duration after abnormalities was found in chest X-ray until lung biopsy was 82.4 days(open lung biopsy: 72.8 days, thoracoscopic lung biopsy: 99.4 days). The bronchoscopy was performed in 272 cases(53.2%), bronchoalveolar lavage was performed in 123 cases(24.1%) and percutaneous lung biopsy was performed in 72 cases(14.1%) before open or thoracoscopic lung biopsy. 4) There were 230 cases(45.0%) of interstitial lung disease, 133 cases(26.0%) of thoracic malignancies, 118 cases(23.1%) of infectious lung disease including tuberculosis and 30 cases (5.9 %) of other lung diseases including congenital anomalies. No significant differences were noted in diagnostic rate and disease characteristics between open lung biopsy and thoracoscopic lung biopsy. 5) The final diagnosis through an open or thoracoscopic lung biopsy was as same as the presumptive diagnosis before the biopsy in 302 cases(59.2%). The identical diagnostic rate was 66.5% in interstitial lung diseases, 58.7% in thoracic malignancies, 32.7% in lung infections, 55.1 % in pulmonary tuberculosis, 62.5% in other lung diseases including congenital anomalies. 6) One days after lung biopsy, $PaCO_2$ was increased from the prebiopsy level of $38.9{\pm}5.8mmHg$ to the $40.2{\pm}7.1mmHg$(P<0.05) and $PaO_2/FiO_2$ was decreased from the prebiopsy level of $380.3{\pm}109.3mmHg$ to the $339.2{\pm}138.2mmHg$(P=0.01). 7) There was a 10.1 % of complication after lung biopsy. The complication rate in open lung biopsy was much higher than in thoracoscopic lung biopsy(12.4% vs 5.8%, P<0.05). The incidence of complication was pneumothorax(23 cases, 4.6%), hemothorax(7 cases, 1.4%), death(6 cases, 1.2%) and others(15 cases, 2.9%). 8) The 5 cases of death due to lung biopsy were associated with open lung biopsy and one fatal case did not describe the method of lung biopsy. The underlying disease was 3 cases of thoracic malignancies(2 cases of bronchoalveolar cell cancer and one malignant mesothelioma), 2 cases of metastatic lung cancer, and one interstitial lung disease. The duration between open lung biopsy and death was $15.5{\pm}9.9$ days. 9) Despite the lung biopsy, 19 cases (3.7%) could not diagnosed. These findings were caused by biopsy was taken other than target lesion(5 cases), too small size to interpretate(3 cases), pathologic inability(11 cases). 10) The contribution of open or thoracoscopic lung biopsy to the final diagnosis was defininitely helpful(334 cases, 66.5%), moderately helpful(140 cases, 27.9%), not helpful or impossible to judge(28 cases, 5.6%). Overall, open or thoracoscopic lung biopsy were helpful to diagnose the lung lesion in 94.4 % of total cases. Conclusions: The open or thoracoscopic lung biopsy were relatively safe and reliable diagnostic method of lung lesion which could not diagnosed by other diagnostic approaches such as bronchoscopy. We recommend the thoracoscopic lung biopsy when the patients were in critical condition because the thoracoscopic biopsy was more safe and have equal diagnostic results compared with the open lung biopsy.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.