• 제목/요약/키워드: Vickers

검색결과 764건 처리시간 0.024초

SHS 공정에 의한 열전대 보호관용 $ZrB_2$ 세라믹스의 제조 (Fabrication of $ZrB_2$ Ceramics for Thermocouple Protective Tubes by SHS Process)

  • 곽철상;김상배;이윤복;박홍채;오기동
    • 한국세라믹학회지
    • /
    • 제34권11호
    • /
    • pp.1165-1172
    • /
    • 1997
  • ZrB2 powders were prepared from a mixture of ZrO2, B2O3 and Mg by self-propagating high temperature synthesis method. The combustion product was successfully obtained from a mixture of ZrO2:B2O3:Mg=1:2:8.5 molar ratio. By-product, MgO was effectively removed by leaching with 1M HCl solution at 9$0^{\circ}C$ for over 5hours. After leaching, the Mg content was 0.86~1.42 wt%, and the mean particle size was 4.72${\mu}{\textrm}{m}$. The addition of 7.5 wt%(14Ni:1.0C) as a sintering aid greatly densified ZrB2 bodies compared with that of only Ni. The ZrB2 sintered bodies containing 7.5 wt%(14Ni:1.0C) was 94.3% of the theoretical density. In this case, ZrB2 existed as a major phase and had a bend strength of 300 MPa and a vickers hardness of 2000 kg/$\textrm{mm}^2$.

  • PDF

Mechanical Behaviour of Non-Oxide Boride Type Ceramics Formed on The AISI 1040 Plain Carbon Steel

  • Sen, Saduman;Usta, Metin;Bindal, Cuma;UciSik, A.Hikmet
    • The Korean Journal of Ceramics
    • /
    • 제6권1호
    • /
    • pp.27-31
    • /
    • 2000
  • A series experiments were performed to evaluate mechanical behavior of non-oxide boride type ceramics formed on the AISI 1040 plain carbon steel. Boronizing was performed in a slurry salt bath consisting of borax, boric acid, and ferro-silicon at $950^{\circ}C$ for 2-6h. The AISI 1040 steel used as substrate material was containing 0.4%C, 0.13%Si, 0.65%Mn, 0.02%P, 0.014%S. The presence of non-oxide boride type ceramics $Fe_2B $ and FeB formed on the surface of steel was confirmed by metallographic technique and X-ray diffraction (XRD) analysis. The hardness of borides measured via Vickers indenter with a load of 2N reached a microhardness of up to 1800 DPN. The hardness of unborided steel was 185 DPN. The fracture toughness of borides measured by means of Vickers indenter with a load of 10N was about 2.30 MPa.$m^{1/2}$. The thickness of boride layers ranged from 72$\mu\textrm{m}$ to 145$\mu\textrm{m}$. Boride layers have a columnar morphology.

  • PDF

비커스 압입 하중에 의한 취성재료의 균열 신호특성 (The Signal Characteristics from Crack of Brittle Materials by Vickers Load)

  • 남기우;김현수
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.125-131
    • /
    • 2002
  • 본 연구에서는 3종류의 취성재료에 비커스 경도기를 사용하여 압축하중에 의한 신호특성과 잔류응력의 에너지 해방에 의하여 검출되는 신호특성을 조사하였다. 각 시험편에서 I영역과 III영역에서는 신호가 검출되었으나, 일정 하중이 유지되는 II영역에서는 음향방출 신호가 전혀 검출되지 않았다. 유리 시험편은 III영역에서 높은 진폭값을 가지는 신호가 검출되었고, $Al_2O_3$$Al_2O_3/SiC$ 시험편은 I영역에서 높은 진폭값을 가지는 신호가 검출되었다.

인장시험을 통한 Sn-xAg-0.5Cu 무연 솔더의 기계적 물성평가 (Estimation of Mechanical Properties of Sn-xAg-0.5Cu Lead-free Solder by Tensile Test)

  • 정종설;신기훈;김종형
    • Journal of Welding and Joining
    • /
    • 제29권1호
    • /
    • pp.41-45
    • /
    • 2011
  • SnAgCu lead-free solder alloy is considered as the best alternative to eutectic tin-lead solder. However, the detailed material properties of SnAgCu solder are not available in public. Hence, this paper presents an estimation of mechanical properties of SnAgCu lead-free solder. In particular, the weight percent of Ag was varied as 1.0wt%, 2.5wt%, 3.0wt%, and 4.5wt% in order to estimate the effect of Ag in the Sn-xAg-0.5Cu ternary alloy system. For this purpose, four types of SnAgCu bars were first molded by casting and then standard specimens were cut out of molded bars. Micro-Vickers hardness, tensile tests were finally performed to estimate the variations in mechanical properties according to the weight percent of Ag. Test results reveal that the higher the weight percent of Ag is, the higher the hardness, yield strength, and ultimate tensile strength become. More material properties will be further investigated in the future work.

초고압을 이용한 나노급 마그네시아 분말의 저온 소결 연구 (Low Temperature Processing of Nano-Sized Magnesia Ceramics Using Ultra High Pressure)

  • 송정호;엄정혜;노윤영;김영욱;송오성
    • 한국세라믹학회지
    • /
    • 제50권3호
    • /
    • pp.226-230
    • /
    • 2013
  • We performed high pressure high temperature (HPHT) sintering for the 20 nm MgO powders at the temperatures from $600^{\circ}C$ to $1200^{\circ}C$ for only 5 min under 7 GPa pressure condition. To investigate the microstructure evolution and physical property change of the HPHT sintered MgO samples, we employed a scanning electron microscopy (SEM), density and Vickers hardness measurements. The SEM results showed that the grain size of the sintered MgO increased from 200 nm to $1.9{\mu}m$ as the sintering temperature increased. The density results showed that the sintered MgO achieved a more than 95% of the theoretical density in overall sintering temperature range. Based on Vickers hardness test, we confirmed that hardness increased as temperature increased. Our results implied that we might obtain the dense sintered MgO samples with an extremely short time and low temperature HPHT process compared to conventional electrical furnace sintering process.

Ti-Pd계 합금의 미세조직변화에 따른 부식거동 (Corrosion Behavior of Ti-Pd System Alloys by Microstructural changes)

  • 차성수;곽동주;남상용
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.9-16
    • /
    • 2008
  • The surface microstructural changes, mechanical properties and corrosion resistance of Ti-Pd alloys for dental biomaterials have been investigated. Ti, Ti-Pd alloys were melted in arc furnace and the corrosion resistance of Ti-Pd alloys was evaluated by anodic polarization test. The surface microstructural changes and mechanical properties of Ti-Pd alloys were analysed by scanning electron microscope and Vickers micro-hardness tester. The vickers hardnees of pure Ti improved by addition of Pd but Ti-25Pd alloy showed decreasing compared with Ti-15Pd. And anodic polarization and potentiostatic test were conducted in 5% HCl to quantify the resistance to corrosion with the addition of Pd, There was no significant difference in corrosion resistance between pure Ti, Ti-5Pd and Ti-15Pd alloy. However, Ti-25Pd alloy showed decreasing compared with pure Ti in corrosion resistance. From these results, it was concluded that newly formulated Ti-15Pd experimental alloy have adequate hardness and high corrosion resistance, and this alloy is promising candidate for a successful dental casting alloy.

  • PDF

SCM440강 용접부의 내식성에 미치는 용접후 열처리효과에 관한 전기화학적 연구 (Electrochemical Study on the Effect of Post-Weld Heat Treatment Affecting to Corrosion Resistance Property of the Weldment of SCM440 Steel)

  • 김성종;김진경;김종호;김기준;김영식;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.78-88
    • /
    • 2000
  • The effect of post-weld heat treatment(PWHT) of SCM440 steel was investigated with parameters such as micro-Vickers hardness, corrosion potential, polarization behaviors, galvanic current, Al anode generating current and Al anode weight loss, etc. Each hardness of three parts(HAZ, BM, WM) by PWHT is lower than each of as-welded parts. However, hardness of WM area was the highest among those three parts in case of both PWHT and as-welded. Corrosion potential of WM part was the highest among those three parts and WM area was also acted as cathode without regard to PWHT. The magnitude of corrosion potential difference among three parts by PWHT was larger than that of three parts of as-welded, and corrosion current by galvanic cell of these three parts by PWHT was also larger compared to as-welded. Therefore, it is suggested that corrosion resistance property of SCM440 steel is decreased by PWHT than as-welded. However, both Al anode generating current and anode weight loss were also increased by PWHT compared to as-welded when SCM400 steel is cathodically protected by Al anode.

  • PDF

점熔接材 의 破壞擧動 과 應力分布 (A Study on Behavior of Fracture and Stress Distribution in Spot Welds)

  • 송삼홍;김부동
    • 대한기계학회논문집
    • /
    • 제8권3호
    • /
    • pp.224-231
    • /
    • 1984
  • 본 연구에서는 이상과 같은 점을 고려하고, 인장시험을 통해 최대용접강도를 나타내는 최적용접조건을 구한 다음, 최적조건하에서 박강판을 1점 점용접한 재료의 너깃주위에 관찰되는 파괴거동을 광탄성 응력분포거동과 관련시켜 고찰하였다.

Magnetic Barkhausen Noise를 이용한 1Cr-1Mo-0.25V강의 열화도 평가 (Evaluation of 1Cr-1Mo-0.25V Steel Degradation Using Magnetic Barkhausen Noise)

  • 이종민;안봉영;남영현;남승훈;이승석;이억섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.250-255
    • /
    • 2001
  • It is inevitable to evaluate the life of turbine rotor because the operating periods of power plants need to be extended. The magnetic methods utilizing Magnetic Barkhausen noise curve were applied to detect the degradation caused by thermal aging. The Magnetic property of material depends on the domain dynamics and it is affected by the microstructure of material. Therefore the magnetic property is very sensitive to the microstructure change of the material. It is, thus, very useful to detect the state of degradation of varying materials. The test specimen made of 1Cr-1Mo-0.25V steel was used widely for turbine rotor material, and seven kinds of specimens with different degradation levels were prepared by the isothermal heat treatment at $630^{\circ}C$. With the increase of degradation, BHN was decreased. The result was compared with coercive force and vickers hardness.

  • PDF

DEPOSITION OF A-SIC:H FILMS ON AN UNHEATED SI SUBSTRATE BY LOW FREQUENCY (50Hz) PLASMA Cvd

  • Shimozuma, M.;Ibaragi, K.;Yoshion, M.;Date, H.;Yoshida, K.;Tagashira, H.
    • 한국표면공학회지
    • /
    • 제29권6호
    • /
    • pp.797-802
    • /
    • 1996
  • Hydrogenated amorphous silicon carbide (a-SiC:H) films have been deposited on unheated substrates by low frequency (50Hz) plasma using $SiH_4+CH_4+H_2$ gas mixtures. Deposition rate, refractive index, optical band gap, Vickers hardness and IR spectrum of the deposited a -SiC:H films have been measured for various rations of gas flow rates k(=$CH_4/SiH_4$, 0.5k4) with a constant $H_2$ flow rate (100sccm). As k increases, the deposition rate of the a-SiC:H films increases up to the maximum value of about 220nm/h at k=2.5, and then it decreases. The refractive index of the films was 2.6 for k=2.5, while the optical band gap of the films was 3.3eV for k=2.2. The maximum value of Vickers hardness of the films was 1500Hv at k=1. The infrared transmission measurement shows that the films contain both Si-C and Si-$CH_3$ bonds.

  • PDF