• 제목/요약/키워드: Vickers' hardness

검색결과 677건 처리시간 0.024초

The effect of different fluoride application methods on the remineralization of initial carious lesions

  • Byeon, Seon Mi;Lee, Min Ho;Bae, Tae Sung
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.121-129
    • /
    • 2016
  • Objectives: The purpose of this study was to assess the effect of single and combined applications of fluoride on the amount of fluoride release, and the remineralization and physical properties of enamel. Materials and Methods: Each of four fluoride varnish and gel products (Fluor Protector, FP, Ivoclar Vivadent; Tooth Mousse Plus, TM, GC; 60 Second Gel, A, Germiphene; CavityShield, CS, 3M ESPE) and two fluoride solutions (2% sodium fluoride, N; 8% tin(ii) fluoride, S) were applied on bovine teeth using single and combined methods (10 per group), and then the amount of fluoride release was measured for 4 wk. The electron probe microanalysis and the Vickers microhardness measurements were conducted to assess the effect of fluoride application on the surface properties of bovine teeth. Results: The amount of fluoride release was higher in combined applications than in single application (p < 0.05). Microhardness values were higher after combined applications of N with FP, TM, and CS than single application of them, and these values were also higher after combined applications of S than single application of A (p < 0.05). Ca and P values were higher in combined applications of N with TM and CS than single application of them (p < 0.05). They were also increased after combined applications of the S with A than after single application (p < 0.05). Conclusions: Combined applications of fluoride could be used as a basis to design more effective methods of fluoride application to provide enhanced remineralization.

$KTP(KTiOPO_4)$ 단결정 육성 및 물성 연구 (제2보) (A study on the growth and properties of KTP single crystals (II))

  • 이명준;차용원;오근호;김판채
    • 한국결정성장학회지
    • /
    • 제4권3호
    • /
    • pp.223-229
    • /
    • 1994
  • $KTP(KTiOPO_4)$ 단결정을 KOH 용액 중에서 수열적으로 육성하였다. 그리고 육성결 정에 대하여 물성 및 Raman spectra를 조사하였다. KTP 단결정의 육서에 있어 KOH와 KF용 액이 효과적인 수열용매이었다. 본 연구에서는 $500^{\circ}C$의 9몰 KOH 용액 중에서 수열육성시킨 KTP 단결정을 갖고 물성조사를 하였으며 그 결과는 다음과 같다. 즉, 격자정수: a = 1.281 nm, c=1.058nm, 밀도: $2.94 g/cm^3$, Vickers 경도: $562kg/cm^2$, 굴절율: $n_e=1.740$, $n_e= 1.747.$이었다. 그리고 수열 육성 KTP 단결정의 Raman spectra를 상온, 상압하에서 조사한 결과 $A_1$ mode는 고온 용액법의 KTP 단결정과 동일 하였으나 $B_2$ mode의 거동은 약간 다르게 관측되었다.

  • PDF

법주사 철확의 부식상태 및 미세조직 분석을 통한 제작기법 연구 (A Study of Manufacturing Techniques Extracting from the Analysis of Corrosion Status and Microstructure for the Cast-Iron Pot in Bubjusa)

  • 한민수;김소진;홍종욱
    • 보존과학회지
    • /
    • 제26권3호
    • /
    • pp.269-276
    • /
    • 2010
  • 법주사 철확의 부식상태 및 미세조직 분석을 통해 제작기법을 추정하고자 광학현미경, SEM-EDS, 미소경도계, XRD를 이용하여 자연과학적 연구를 실시하였다. 표면층의 미세조직에서는 페라이트와 일부 펄라이트 조직이 관찰되었다. 내부층에서는 펄라이트 조직과 깃털모양의 흑연이 관찰되었으며, 중간 경계층에서는 심한 부식현상이 관찰된다. 미소경도는 조직별로 217Hv~698Hv 값의 범위를 가졌으며, 이는 일반적으로 고대 철제유물에서 보이는 경도 값 범위이다. 각 층별 미세조직에 대한 성분분석 결과, 표면층이 내부층에 비해 탈탄이 많이 되었음을 알 수 있었다. 금속 부식화합물의 XRD 동정 결과, 일반적인 금속유물의 부식과정에서 만들어지는 침철석과 적철석이 동정되었다. 결론적으로 법주사의 대형 철확은 주조기술로 제작되었으며, 내부는 흑연을 포함한 회주철 조직을 보이고 있다. 또한 표면층은 사용과정에서 가열과 냉각의 반복으로 탈탄작용이 일어났다. 이러한 연구결과는 대형 철확의 제작기법을 밝히는데 중요한 비교자료로 활용될 수 있을 것이다.

Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA)

  • Naji, Sahar Abdulrazzaq;Behroozibakhsh, Marjan;Kashi, Tahereh Sadat Jafarzadeh;Eslami, Hossein;Masaeli, Reza;Mahgoli, Hosseinali;Tahriri, Mohammadreza;Lahiji, Mehrsima Ghavvami;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.113-121
    • /
    • 2018
  • PURPOSE. The aim of this preliminary study was to investigate, for the first time, the effects of addition of titania nanotubes ($n-TiO_2$) to poly methyl methacrylate (PMMA) on mechanical properties of PMMA denture base. MATERIALS AND METHODS. $TiO_2$ nanotubes were prepared using alkaline hydrothermal process. Obtained nanotubes were assessed using FESEM-EDX, XRD, and FT-IR. For 3 experiments of this study (fracture toughness, three-point bending flexural strength, and Vickers microhardness), 135 specimens were prepared according to ISO 20795-1:2013 (n of each experiment=45). For each experiment, PMMA was mixed with 0% (control), 2.5 wt%, and 5 wt% nanotubes. From each $TiO_2$:PMMA ratio, 15 specimens were fabricated for each experiment. Effects of $n-TiO_2$ addition on 3 mechanical properties were assessed using Pearson, ANOVA, and Tukey tests. RESULTS. SEM images of $n-TiO_2$ exhibited the presence of elongated tubular structures. The XRD pattern of synthesized $n-TiO_2$ represented the anatase crystal phase of $TiO_2$. Moderate to very strong significant positive correlations were observed between the concentration of $n-TiO_2$ and each of the 3 physicomechanical properties of PMMA (Pearson's P value ${\leq}.001$, correlation coefficient ranging between 0.5 and 0.9). Flexural strength and hardness values of specimens modified with both 2.5 and 5 wt% $n-TiO_2$ were significantly higher than those of control ($P{\leq}.001$). Fracture toughness of samples reinforced with 5 wt% $n-TiO_2$ (but not those of 2.5% $n-TiO_2$) was higher than control (P=.002). CONCLUSION. Titania nanotubes were successfully introduced for the first time as a means of enhancing the hardness, flexural strength, and fracture toughness of denture base PMMA.

가역투자율에 의한 12Cr 페라이트 내열강의 역학적 물성의 열화평가 (Degradation Evaluation of Mechanical Properties for 12Cr Ferrite Heat Resisting Steel by Reversible Permeability)

  • 유권상;김민기;남승훈;김정석
    • 비파괴검사학회지
    • /
    • 제30권5호
    • /
    • pp.464-470
    • /
    • 2010
  • 고온, 고압에서 운용되고 있는 설비의 안전성을 평가하기 위해서는 사용시간 동안 열화된 역학물성을 정기적으로 점검하여야 한다. 비파괴적으로 열화된 설비의 역학적 특성을 점검하기 위하여 표면형 프로브(surface type probe)를 사용한 가역투자율 측정방법이 제시된다. 가역투자율 측정방법은 가역투자율이 자기 이력곡선의 미분값임에 근거하고 있다. 가역투자율은 교류 섭동 자기장의 주파수에 동조된 록-인 증폭기로 측정된 탐지코일에 유도된 전압의 제 1 고조파이다 가역투자율의 첨두값은 보자력 영역에서 나타난다. 실험에 사용된 강재는 12Cr 페라이트 내열강으로 $700^{\circ}C$의 등온에서 열처리 시간을 달리한 11개의 시편을 제작하였다. 가역투자율 첨두값 사이의 간격 (peak interval of reversible permeability: PIRP), 비커스 경도 및 인장강도는 열화가 진행됨에 따라 초기에는 급격하게, 후반에는 완만하게 감소하였다. PIRP가 감소함에 따라 인장강도와 비커스 경도가 선형적으로 감소하였고 이 상관관계를 이용하면 측정한 가역투자율로 12Cr 페라이트 내열강의 열화된 역학적 물성을 비파괴적으로 평가할 수 있다.

이온선 혼합법이 도재와 금속의 결합에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECTS OF ION BEAM HIKING ON CERAMO-METAL BONDING)

  • 홍준표;우이형;최부병
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.245-265
    • /
    • 1991
  • The purpose of this study was to observe the changes of the elemental transmission and bond strength between the metal and porcelain according to various kinds of ion beam mixing method. ion beam mixing of $meta1/SiO_2$ (silica), $meta1/Al_2O_3$(alumina) interfaces causes reactions when the $Ar^+$ was implanted into bilayer thin films using a 100KeV accelerator which was designed and constructed for this study. A vacuum evaporator used in the $10^{-5}-10^{-6}$ Torr vacuum states for the evaporation. For this study, three kinds of porcelain metal selected, -precious, semiprecious, and non-precious. Silica and alumina were deposited to the metal by the vacuum evaporator, separately. One group was treated by two kinds of dose of the ion beam mixing $(1\times10^{16}ions/cm^2,\;5\times10^{15}ions/cm^2)$, and the other group was not mixed, and analyzed the effects of ion beam mixing. The analyses of bond strength, elemental transmissions were performed by the electron spectroscopy of chemical analysis (ESCA), light and scanning electron microscope, scratch test, and micro Vickers hardness tests. The finding led to the following conclusions. 1. In the scanning electron and light microscopic views, ion beam mixed specimens showed the ion beam mixed indentation. 2. In the micro Vickers hardness and scratch tests, ion beam mixed specimens showed higher strength than that of non mixed specimens, however, nonprecious metal showed a little change in the bond strength between mixed and non mixed specimens. 3. In the scratch test, ion beam mixed specimens showed higher shear strength than that of non treated specimens at the precious and semiprecious groups. 4. In the ESCA analysis, Au-O and Au-Si compounds were formed and transmission of the Au peak was found ion beam mixed $SiO_2/Au$ specimen, simultaneously, in the higher and lower bonded areas, and ion beam mixed $SiO_2/Ni-Cr$ specimen, oxygen, that was transmitted from $SiO_2\;to\;SiO_2/Ni-Cr$ interface combined with 12% of Ni at the interface.

  • PDF

도재용착주조관용 Ni-Cr 합금의 반복주조가 부식거동에 미치는 영향 (The Effect of Recasting on the Corrosion behavior of Ni-Cr alloy for Porcelain Fused to Metal Crown)

  • 배수현;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.355-366
    • /
    • 2006
  • The purpose of this study was to determine if repeated casting has a detrimental effect on the corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis, vickers hardness test, SEM, EDX and corrosion test were performed to determine the effects of recasting on chemical composition, microstructure, physical property, castability and corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed that major crystal phase contained nickel-chrome compounds, Nickel carbide and Chrome carbide. Microstructure analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed recasting has no effect on microstructure. EDX analysis results indicated the percentage of the main component nickel(Ni) in the specimens of the VeraBond showed a tendency to increase with recasting, but those of other components Carbon(C) showed a tendency to decrease with recasting, Chrome(Cr), Silicon(Si), Aluminium(Al) and molybdenum(Mo) showed no changes in the percentage. The percentage of the main component nickel(Ni) in the specimens of the Rexillium V showed a tendency to increase with recasting, but those of other components silicon(Si), carbon(C) and molybdenum(Mo) showed a tendency to decrease with recasting, chrome(Cr) and aluminium(Al) showed no changes in the percentage. The vickers hardness results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The castability results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The cast and recast specimens of the VeraBond and the Rexillium V showed no differences in the corrosion resistance. The results indicate that the VeraBond and the Rexillium V can be safely recast.

  • PDF

Effect of Ultra-Soft and Soft Toothbrushes on the Removal of Plaque and Tooth Abrasion

  • Jeong, Moon-Jin;Cho, Han-A;Kim, Su-Yeon;Kang, Ka-Rim;Lee, Eun-Bin;Lee, Ye-Ji;Choi, Jung-Hyeon;Kil, Ki-Sung;Lee, Myoung-Hwa;Jeong, Soon-Jeong;Lim, Do-Seon
    • 치위생과학회지
    • /
    • 제18권3호
    • /
    • pp.164-171
    • /
    • 2018
  • To improve the oral health status of Korean people, it is necessary to encourage proper oral hygiene management habits, such as toothbrushing, through appropriate health promotion techniques. Therefore, the purpose of this study was to evaluate the removal of plaque and tooth abrasion using ultra-soft (filament 0.11~0.12 mm) and soft toothbrushes for toothbrushing. The plaque removal was performed using a dentiform and Arti-spray, and the Patient Hygiene Performance (PHP) index was calculated as the sum total score divided by the total number of surfaces. In the abrasivity experiment, according to the number of brushings, a micro Vickers hardness tester was used, and a sample in the range of 280~380 Vickers hardness number was selected. The number of toothbrushing stroke were 1,800 (2 months), 5,400 (6 months), 10,800 (12 months), and 21,600 (24 months). The tooth abrasion was measured using a scanning electron microscope. Statistical analysis was performed using IBM SPSS Statistics 22.0 and a p-value <0.05 was considered significant. According to the results, there was no statistically significant difference in the degree of plaque removal between ultra-soft and soft toothbrushes. The difference in tooth abrasion between before and after toothbrushing was found to be greater with the soft toothbrushes than with the ultra-soft toothbrushes. Therefore, the ultra-soft toothbrush not only lowers tooth damage by reducing tooth abrasion, but also shows a similar ability to remove plaque as soft toothbrushes.

치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 - (THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS)

  • 이용근;이건일;정성우
    • 치과방사선
    • /
    • 제26권2호
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

치과용 아말감의 미세경도에 관한 실험적연구 (AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF