• 제목/요약/키워드: Vibration source

검색결과 1,235건 처리시간 0.026초

대형펌프와 조합된 배관계 진동 저감 (Vibration Reduction of Pump And Pipe System)

  • 배춘희;원종범;조철환;양경현;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.652-657
    • /
    • 2000
  • In this paper, Firstly, it is shown that the high vibration source of piping system is the pulsation transmission of pipe line element, such as, orifice plate, valves and the control valve is a broad band source and the branch wall and the cavity have vortex frequency. Secondly, in order to decrese the high vibration of piping system, some practical Friction damper with high damping have been developed and its effectiveness is investigated as installing it at piping system practically.

  • PDF

수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측 (Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings)

  • 김명준;김흥식;김하근
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

Projector 회로 소음 및 진동 저감의 실험적 연구 (An Experimental Study on the Noise and Vibration reduction of Projector Driving Board)

  • 최영수;송근영;이종권;오홍렬;이승규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.135-140
    • /
    • 2013
  • This paper deals with noise reduction on a light source driving board in a projector. We analyze causes of noise/vibration in the circuit with the present increasing use of LD and LED driving boards. The main source of noise is the MLCC in the driving board. Our aim is to investigate how the mechanical arrangement of the circuit elements affects noise reduction. The result of our experiment shows that noise can be reduced by symmetrical arrangement and slots in PCB. This result is expected to facilitate a variety of applications for manufactures without a need to change circuit elements.

  • PDF

회전체 진동으로 인한 판넬 방사소음의 실험적 기여도 분석 (An Experimental Analysis of the Contributions to the Radiated Noise due to Panel Vibration of a Rotational Machine)

  • 국형석;허승진;고강호
    • 한국소음진동공학회논문집
    • /
    • 제13권2호
    • /
    • pp.126-131
    • /
    • 2003
  • This study is concerned with the reduction of noise radiation by an industrial fan unit. First, spectral decomposition method is used to decompose the spectrogram obtained in experiments into source function and noise transfer function, and then major noise generation sources are investigated. Among the noise sources involved in the fan unit. this article is focused on the noise source due to vibration of panels of the unit housing. It is shown here that noise radiation associated with the panel vibration can be as significant in some frequency ranges as that associated with other noise sources such as aeroacoustic fan noise.

Synchronous Periodic Frequency Modulation Based on Interleaving Technique to Reduce PWM Vibration Noise

  • Zhang, Wentao;Xu, Yongxiang;Ren, Jingwei;Su, Jianyong;Zou, Jibin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1515-1526
    • /
    • 2019
  • Ear-piercing high-frequency noise from electromagnetic vibrations in motors has become unacceptable in sensitive environments, due to the application of pulse width modulation (PWM) and in consideration of switching losses. This paper proposed a synchronous periodic frequency modulation (SPFM) method based on the interleaving technique for paralleled three-phase voltage source inverters (VSIs) to eliminate PWM vibration noise. The proposed SPFM technique is able to effectively remove unpleasant high-frequency vibration noise as well as acoustic noise more effectively than the conventional periodic carrier frequency modulation (PCFM) and interleaving technique. It completely eliminates the vibration noise near odd-order carrier frequencies and reduces the PWM vibration noise near even-order carrier frequencies depending on the switching frequency variation range. Furthermore, the SPFM method is simple to implement and does not employ additional circuits in the drive system. Finally, the effectiveness of the proposed method has been confirmed by detailed experimental results.

An innovative vibration barrier by intermittent geofoam - A numerical study

  • Majumder, Mainak;Ghosh, Priyanka;Sathiyamoorthy, Rajesh
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.269-284
    • /
    • 2017
  • A new technique is proposed to obtain more effective screening efficiency against the ground vibration using intermittent geofoam (IF) in-filled trench. The numerical analysis is performed by employing two-dimensional finite element method under dynamic condition. Vertically oscillated strip foundation is considered as the vibration source. In presence of the ground vibration, the vertical displacements at different locations (pick-up points) along the ground surface are captured to determine the amplitude reduction factor (ARF), which helps to assess the efficiency of the vibration screening technique. The efficiency of IF over continuous geofoam (CF) in-filled vibration barriers is assessed by varying the geofoam density, the location of trench and the frequency of excitation. The results from this study indicate that a significant reduction in ARF can be achieved by using intermittent geofoam as compared to continuous geofoam. Further, it is noticed that the efficiency of IF increases with an increase in the frequency of the vibrating source. These encouraging results put forward the potential of utilising intermittent geofoam as a vibration screening material.

유한 요소법을 이용한 나 슬래브의 2차원 바닥 충격진동 해석 (2-Dimensional Floor Impact Vibration Analysis in Bare Reinforced Concrete Slab Using Finite Element Method)

  • 서상호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.604-611
    • /
    • 2005
  • The relationship between floor impact sound and vibration has been studied by field measurements, and the vibration modal characteristics have been analyzed. Vibration levels impacted by a standard heavy-weight impact source have been predicted according to the main design parameters using finite element method. Experimental results show that the dominant frequencies of the heavy impact sounds range below 100 Hz and that they are coincident with natural frequencies of the concrete slab. In addition, simple 2-dimensional finite element models are proposed to substitute 2 types of 3-dimensional models of complicated floor structural slabs those by The analytical result shows that the natural frequencies from first to fifth mode well correspond to those by experiments with an error of less than $12\%$, and acceleration peak value iscoincident with an error of less than $2\%$. Using the finite element model. vibration levels areestimated according to the design Parameters, slab thickness, compressive strength, and as a result, the thickness is revealed as effective to increase natural frequencies by $20\~30\%$ and to reduce the vibration level by 3$\~$4 dB per 30 mm of extra thickness.

Design optimization of vibration isolation system through minimization of vibration power flow

  • Xie, Shilin;Or, Siu Wing;Chan, Helen Lai Wa;Choy, Ping Kong;Liu, Peter Chou Kee
    • Structural Engineering and Mechanics
    • /
    • 제28권6호
    • /
    • pp.677-694
    • /
    • 2008
  • A vibration power minimization model is developed, based on the mobility matrix method, for a vibration isolation system consisting of a vibrating source placed on an elastic support structure through multiple resilient mounts. This model is applied to investigate the design optimization of an X-Y motion stage-based vibration isolation system used in semiconductor wire-bonding equipment. By varying the stiffness coefficients of the resilient mounts while constraining the dynamic displacement amplitudes of the X-Y motion stage, the total power flow from the X-Y motion stage (the vibrating source) to the equipment table (the elastic support structure) is minimized at each frequency interval in the concerned frequency range for different stiffnesses of the equipment table. The results show that when the equipment table is relatively flexible, the optimal design based on the proposed vibration power inimization model gives significantly little power flow than that obtained using a conventional vibration force minimization model at some critical frequencies. When the equipment table is rigid enough, both models provide almost the same predictions on the total power flow.

가속도 충격파형을 이용한 기기의 결함 위치분석 및 진단사례 (Case_study of detecting loose part by acceleration signal)

  • 유무상;박승도;박현철;최낙균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.463-468
    • /
    • 2007
  • The abnormal sound of generator frame is analyzed by a acceleration signal. The spike-like time signal is major characteristics of impacting force. The distributional map of vibration level is one of visualization method. With map, noise source was easily detected. After de_assembly of generator, loose part of internal component is the source of impact force by mechanical movement of stator inherently. In contact condition of part with clearance, the level of impact signal is different at each revolution and impact signal did not happens periodically.

  • PDF

밀봉선원의 성능시험을 위한 장치 개발 및 적용 (Development and Application of Test Apparatus for Classification of Sealed Source)

  • 김동학;서기석;방경식;이주찬;손광재
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.35-44
    • /
    • 2007
  • 밀봉선원은 과학기술부고시에 의거하여 사용용도별로 등급에 따라 해당 성능시험을 수행하고, 각 성능시험을 거친 후 해당 방사성핵종의 방사능 누설량이 200베크렐을 초과하지 아니하여야 한다. 이러한 성능시험은 온도시험, 의부압력시험, 충격시험, 진동시험 및 관통시험으로 구성되어 있으며 등급에 따라서 각 성능시험의 조건이 각각 다르다. 본 연구에서는 진동시험을 제외한 성능시험을 위한 장치를 개발하고 이를 세 가지 종류의 밀봉선원의 성능시험에 적용하였다. 의료용 근접치료기에 사용되는 근접치료기용 선원은 5등급의 온도시험, 3등급의 외압시험, 2등급의 충격시험을 수행하여 'C53211' 등급의 기준에 적합함을 보였다. 산업용 조사기에 사용되는 $^{75}Se$$^{169}Yb$ 선원에 대하여 4등급의 온도시험, 3등급의 외압시험, 5등급의 충격시험과 관통시험을 실시하여 'C43515' 등급의 기준에 적합함을 입증하였다.