• 제목/요약/키워드: Vibration source

검색결과 1,235건 처리시간 0.024초

NOISE SOURCE IDENTIFICATION WITH INCREASED SPATIAL RESOLUTION

  • Gade, Svend;Hald, Jorgen;Ginn, Bernard
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.636-642
    • /
    • 2012
  • Delay-and-sum (DAS) Planar Beamforming has been a widely used Noise Source Identification Technique for the last decade. It is a quick one shot measurement technique being able to map sources that are larger than the array itself. The spatial resolution is proportional to distance between array and source, and inversely proportional to wavelength, thus the resolution is only good at medium to high frequencies. Improved algorithms using iterative de-convolution techniques offers up to ten times better resolution. The principle behind these techniques is described in this paper, as well as measurement examples from the automotive industry are presented.

  • PDF

불규칙 작용힘들간의 Correlation이 평판의 진동레벨에 미치는 영향 (Effects of Source Correlation on Plates Driven by Multi-point Random Forces)

  • Oh, S.G.;Park, J.D.;Kwak, C.S.
    • 한국정밀공학회지
    • /
    • 제11권1호
    • /
    • pp.166-176
    • /
    • 1994
  • The problem of reducing the vibration level of elastic plates driven by multiple random point forces is analyzed in this study. First, the analytical solution for the vibration level of finite thin plates with four simply supported edges under the action of multiple random point force is derived. By assuming the plates to be lightly damped, an approximate solution for the vibration level of the plate is obtained. A numerical study is carried out to determine an optimal spacing distance between the multiple point forces in order to produce a relative minimum in the plate's vibration level. The optimal spacing distance is shown to depend on the given excitation band. The effects of wave cancellation in the near field of the multiple point forces are discussed by using the equivalence of certain stationary random responses and deterministic pulse responese.

  • PDF

건설 소음.진동의 사전 영향성 분석에 관한 연구 (Study on Preliminary Influence Analysis of Construction Noise and Vibration)

  • 안명석;김화일;박주한
    • 화약ㆍ발파
    • /
    • 제32권2호
    • /
    • pp.25-30
    • /
    • 2014
  • 건설공사 현장에서 발생하는 소음 진동은 일시적이고 간헐적으로 발생하지만 그 영향은 매우 크다. 건설기계의 적은 소음 진동이라도 발생하면 먼 거리까지 전달되어 차음 및 방진 등의 대책이 어려워 이를 해결하기 위해 본 연구에서는 건설장비의 소음 진동 안전기준을 30m로 적용하였고 발파소음은 60m, 진동은 160m로 적용하였다. 지금까지는 2D를 사용한 모델링을 주로 사용하였으나 건물이나 산과 언덕 등 크기와 높이를 고려한 3차원 3D 모델링으로 측정 분석하여서 정확도를 높였다.

발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명 (Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site)

  • 김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

Outer Rotor Type BLDC 모터의 슬롯 수에 따른 진동 특성 분석 (Analysis of Outer Rotor Type BLDC motor vibration characteristics according to slot combination)

  • 방기창;김광석;권중학;이영욱;황상문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.196-201
    • /
    • 2008
  • This paper is about electromagnetic vibration source in outer rotor type of BLDC motors. Experiments are carried out with three pole-slot combinations which are 6 slots, 12 slots, and 24 slots with 4 poles rotor. According to results, vibration sources separate into electromagnetic and mechanical factors. Using the finite element method (FEM), It is analyed that vibration characteristics of electromagnetic source in each type. This paper shows electromagnetic sensitivity to vibration, and introduces necessary point in lower vibration motors. Also rotor balance is important to prevent uneven distribution of magnetic flux between rotor and stator.

  • PDF

역경계요소법에 근거한 근접 음향 홀로그래피에서 강체 산란체의 이용 (Use of Rigid Scattering Body in the use of NAH based on the inverse BEM)

  • 김성일;정지훈;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.486-489
    • /
    • 2004
  • The NAH based on the inverse BEM is used to reconstruct the source field, which is advantageous in dealing with the irregular source. In the implementation of this technique, a large number of pressure measurements is required because an over-determined pressure data set is required. These conditions accordingly cause the increase of measurement time and associated effort along with the error due to mal-positioning. The purpose of this study is to reduce such inconveniences: Instead of increasing the number of field pressure data, the number of transfer paths between the source and the receiver is increased by placing rigid scattering body in-between the source and receiver. For validating the usefulness and effectiveness of the method, the numerical analyses of interior problem are demonstrated. As a result, it is thought that the proposed method enables the measurement at smaller number of sensor positions and the monitoring of surface vibration with less experimental effects than before.

  • PDF

차량용 A/V 시스템의 구동부 소음원과 래틀 소음원에 관한 연구 (A Study on Noise Source Identification for Loading Mechanism and Rattle noise about A/V System)

  • 홍종호;강연준;이상호;이완우;이기석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.189-195
    • /
    • 2003
  • This paper represents an identification procedure for leading mechanism of a car A/V system which is composed of a DC motor and a set of plastic gears. In addition, we studied dominant noise source of rattle noise generated by external forced vibration as a car drives. we made a dynamometer to produce stationary operation on loading mechanism of A/V system because noise generated by actual loading mechanism is non-stationary signal. operating the dynamometer setup at various motor speeds, sound pressure spectra are measured and the results are analyzed. its dominant noise source is also identified by using a sound Intensity technique. we made use of multi-dimensional spectral analysis to rind a dominant rattle noise. this method is so useful to eliminate coherence between vibration sources and helps us obtain coherent output spectrum of individual vibration source which make a rattle noise.

  • PDF

실험적 모드해석을 이용한 방사광 가속기 건물의 진동평가 (Vibration Estimation of Synchrotron Light Source Building Using Experimental Modal Analysis)

  • 박상규;이홍기;권형오
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.413-421
    • /
    • 1995
  • 냉난방용 회전기기에 의한 방사광가속기 건물의 진동은 내부에 설치되어 있는 광학장치나 전자장비의 성능에 영향을 미치기 때문에 건설단계에서 부터 건물 진동에 대한 평가가 매우 중요하다. 본 연구에서는 방사광가속기 건물의 진동을 평가 하기 위해서 실험적 모우드해석법을 이용하여 냉난방기기가 위치한 바닥의 동적특성 을 구하고, 하중응답 모사법을 통해 진동응답치를 계산하였다. 평가결과, 건물바닥의 진동치는 기준치를 상회하고 있으며 이를 해결하기 위해 이중방진 시스템을 설계 제작하여 냉난방기기와 바닥 사이에 설치함으로써 바닥의 진동을 허용한도 이내로 감소시켰다.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 장서일;이연수
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.