• Title/Summary/Keyword: Vibration mitigation

Search Result 180, Processing Time 0.026 seconds

Mitigation of motions of tall buildings with specific examples of recent applications

  • Kareem, Ahsan;Kijewski, Tracy;Tamura, Yukio
    • Wind and Structures
    • /
    • v.2 no.3
    • /
    • pp.201-251
    • /
    • 1999
  • Flexible structures may experience excessive levels of vibration under the action of wind, adversely affecting serviceability and occupant comfort. To ensure the functional performance of a structure, various design modifications are possible, ranging from alternative structural systems to the utilization of passive and active control devices. This paper presents an overview of state-of-the-art measures that reduce the structural response of buildings, including a summary of recent work in aerodynamic tailoring and a discussion of auxiliary damping devices for mitigating the wind-induced motion of structures. In addition, some discussion of the application of such devices to improve structural resistance to seismic events is also presented, concluding with detailed examples of the application of auxiliary damping devices in Australia, Canada, China, Japan, and the United States.

A Study on the Interior Noise Characteristics of KTX with Improved Mud Flap for Various Track Conditions (머드플랩이 개선된 KTX차량의 궤도구간별 실내소음 특성에 관한 연구)

  • Kim, Jin-Ho;Kim, Woo-Ri;Park, Dae-Geun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.345-349
    • /
    • 2006
  • There has been an increasing demand for the mitigation of noise and vibration caused by KTX. One of considered noise reduction methods which is to enlarge mud-flap in gangway was selected and the replacement of all KTX mud-flaps by improved mud-flaps was completed recently. To investigate the noise characteristics of KTX with improved mud-flap, the measurement was performed. Based on the measurement results, the assessment of noise level, noise characteristics by speed and pure tone analysis for various track conditions was executed. It is shown that the use of improved mud-flap is effective to reduce the interior noise of KTX.

  • PDF

Approach zone of parametric analysis for hardness mitigation of connection (접속부의 강성완화를 위한 Approach zone의 매개분석)

  • Son, Ji-Hyun;Choi, Jin-You;Oh, Ji-Taek;Hwang, Won-Sup
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.558-564
    • /
    • 2006
  • When vehicles pass the connection between the bridge and earthwork, the difference of both sections' stiffness produces an increasing wheelload. As a consequence, it results in the excessive vibration of vehicles and the damage of bearing system. In general, steel plate girder railway bridges without ballast track have larger stiffness than the bridge with ballast, and produces larger impulse on the bridge superstructure. Thus, it is necessary to reduce the differences of both stiffness. This study presents parametric studies on the behavior of plate girder bridges and their tracks by means of various stiffnesses and the length of approach zone. The results of numerical study showed that the smaller the stiffness of both sides and the longer the length of approach zone, the variation of wheelload becomes smaller. Hence, it gives less burden into the plate girder bridges and their tracks. It is expected that the results of parametric study can be used as a preliminary data for the determination of economical length on the approach zone and the stiffness of both sides.

  • PDF

Experimental study on lead extrusion damper and its earthquake mitigation effects for large-span reticulated shell

  • Yang, M.F.;Xu, Z.D.;Zhang, X.C.
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.481-496
    • /
    • 2015
  • A Lead Extrusion Damper (LED) is experimentally studied under various frequencies and displacement amplitudes. Experimental results show that the force-displacement hysteresis loops of the LED are close to rectangular and the force-velocity hysteresis loops exhibit nonlinear hysteretic characteristic. Also, the LED can provide consistent energy dissipation without any stiffness degradation. Based on the experimental results, a mathematical model is then proposed to describe the effects of frequency and displacement on property of LED. It can be proved from the comparison between experimental and numerical results that the mathematical model can accurately describe the mechanical behavior of LED. Subsequently, the seismic responses of the Schwedler reticulated shell structure with LEDs are analyzed by ANSYS software, in which three different installation forms of LEDs are considered. It can be concluded that the LED can effectively reduce the displacement and acceleration responses of this type of structures.

Application of monodisperse Fe3O4 submicrospheres in magnetorheological fluids

  • Anupama, A.V.;Kumaran, V.;Sahoo, B.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.347-357
    • /
    • 2018
  • Steady shear response of a magnetorheological fluid (MRF) system containing porous mono-disperse magnetite ($Fe_3O_4$) spheres synthesized by solvothermal method is demonstrated. In applied magnetic field the interaction between the spherical particles leads to form strong columnar structures enhancing the yield strength and viscosity of the MRFs. The yield strengths of the MRFs also scale up with the concentration of magnetic particles in the fluid. Considering magnetic dipolar interaction between the particles the magneto-mechanical response of the MRFs is explained. Unlike metallic iron particles, the low-density corrosion resistant soft-ferrimagnetic $Fe_3O_4$ spherical particles make our studied MRF system efficient and reliable for shock-mitigation/vibration-isolation applications.

Optimal deep machine learning framework for vibration mitigation of seismically-excited uncertain building structures

  • Afshin Bahrami Rad;Javad Katebi;Saman Yaghmaei-Sabegh
    • Structural Engineering and Mechanics
    • /
    • v.88 no.6
    • /
    • pp.535-549
    • /
    • 2023
  • Deep extreme learning machine (DELM) and multi-verse optimization algorithms (MVO) are hybridized for designing an optimal and adaptive control framework for uncertain buildings. In this approach, first, a robust model predictive control (RMPC) scheme is developed to handle the problem uncertainty. The optimality and adaptivity of the proposed controller are provided by the optimal determination of the tunning weights of the linear programming (LP) cost function for clustered external loads using the MVO. The final control policy is achieved by collecting the clustered data and training them by DELM. The efficiency of the introduced control scheme is demonstrated by the numerical simulation of a ten-story benchmark building subjected to earthquake excitations. The results represent the capability of the proposed framework compared to robust MPC (RMPC), conventional MPC (CMPC), and conventional DELM algorithms in structural motion control.

Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control

  • Yu, Yang;Royel, Sayed;Li, Jianchun;Li, Yancheng;Ha, Quang
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.943-966
    • /
    • 2016
  • Recently, magnetorheological elastomer (MRE) material and its devices have been developed and attracted a good deal of attention for their potentials in vibration control. Among them, a highly adaptive base isolator based on MRE was designed, fabricated and tested for real-time adaptive control of base isolated structures against a suite of earthquakes. To perfectly take advantage of this new device, an accurate and robust model should be built to characterize its nonlinearity and hysteresis for its application in structural control. This paper first proposes a novel hysteresis model, in which a nonlinear hyperbolic sine function spring is used to portray the strain stiffening phenomenon and a Voigt component is incorporated in parallel to describe the solid-material behaviours. Then the fruit fly optimization algorithm (FFOA) is employed for model parameter identification using testing data of shear force, displacement and velocity obtained from different loading conditions. The relationships between model parameters and applied current are also explored to obtain a current-dependent generalized model for the control application. Based on the proposed model of MRE base isolator, a second-order sliding mode controller is designed and applied to the device to provide a real-time feedback control of smart structures. The performance of the proposed technique is evaluated in simulation through utilizing a three-storey benchmark building model under four benchmark earthquake excitations. The results verify the effectiveness of the proposed current-dependent model and corresponding controller for semi-active control of MRE base isolator incorporated smart structures.

Dynamic Behavior of Curved Bridges under Seismic Loading (지진하중을 받는 곡선교량의 동적거동)

  • Park, Nam-Hoi;Yoon, Ki-Yong;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.11-21
    • /
    • 2005
  • This study is performed to understand complex behavior and to investigate the rational analysis methods for seismic design of the curved bridges. To analyze the curved bridges for the seismic loadings, it is used that the finite element analysis program has the 7-dof curved beam and straight beam element. The free vibration characteristics of the curved bridges are compared with the straight bridges that have span length same as the average arc length of inside and outside girder of those. For the same case, the dynamic behavior is compared under seismic loadings. It is found that regular bridges classified by AASHTO are analyzed as if those were straight. To investigate the dynamic behavior of general curved bridges under seismic loading, the seismic loading directions and the subtended angle of curved bridges are varied.

Dynamic Serviceability Estimation of the Simple Railway Bridge with PSC I Girder (PSC I형 단순 철도교량의 동적사용성 평가)

  • Kang, Sung-Hoo;Choi, Tae-Geun;Park, Sun-Joon;Kim, Sung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • In this study, dynamic serviceability of PSC, PreStressed Concrete, simple railway bridge with 25m span was estimated. All of the high speed and general train loads were considered at estimation. Natural frequency is estimated about 8Hz and includes within optimum natural frequency extent of the railway bridge. Also, the bridge was detected that resonance occurrence possibility does not exist. When travel the Moogunghwa train, acceleration response was measured to 0.43g that exceed limitation value 0.35g. Also, rotation angle of girders end did not satisfy design standard of railway bridge for high speed train, but impact coefficient and deflection satisfied design standard. As a result, that railway bridge was detected that is securing dynamic safety and serviceability partially, but methods to decrease vibration acceleration response are required.

Stability Analysis of DCM treated Ground Using Centrifuge Test (원심모형시험을 이용한 DCM 처리지반의 안정성 평가)

  • Kim, Byoung-Il;Yoo, Wan-Kyu;Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.105-110
    • /
    • 2011
  • Recently, a deep mixture method as a soil improvement method of marine soft ground, which causes less noise and vibration than other methods, are widely used. In this study, for DCM(Deep Cement Mixing) method, one of the deep mixture method, optimum mixing ratio of clay-cement was suggested using uniaxial compression tests on specimens with various mixing ratio of claycement. In addition, the stability of a caisson on tangent circle-type and wall-type DCM treated ground was evaluated using centrifuge tests. As a result, optimum mixing ratio of clay-cement was 28.5% and the stability of the caisson on DCM treated ground was confirmed. However, the lateral displacement of the caisson on the wall-type DCM treated ground was 7% less and the settlement of that was 39% less than the case of the tangent-circle-type DCM method.