• Title/Summary/Keyword: Vibration frequency

Search Result 6,241, Processing Time 0.043 seconds

Performance Evaluation on an Active Hybrid Mount System for Naval Ships Using Piezostack Actuator (압전작동기를 이용한 함정용 능동 하이브리드 마운트 시스템의 진동제어 성능 평가)

  • Quoc, Nguyen Vien;Choi, Seung-Boh;Oh, Jong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • In this work, a new active hybrid mount featuring piezostack actuator and rubber element is proposed, and its vibration control performance is evaluated by applying a robust frequency-shaped sliding mode controller. After describing the configuration of the proposed mount, vibration control performances are experimentally evaluated. A mount system with four active hybrid mounts is then constructed. To attenuate vibrations on the supported mass, a frequency-shaped sliding mode controller is designed and implemented to the system. Finally, control performances are obtained and presented in time and frequency domains via computer simulation.

Simultaneous Measurement of Strain and High Frequency Vibration of Composite Main Wing Model (복합재 주 날개 모델의 변형률과 진동의 동시 측정)

  • Song, Ji-Yong;Yoon, Hyuk-Jin;Park, Sang-Wuk;Park, Sang-Oh;Kim, Chon-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.185-189
    • /
    • 2005
  • For the simultaneous measurement of strain and vibration signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter could measure low-frequency signal such as strain and the other demodulator using a coarse wavelength division multiplexer could detect high-frequency signal such as vibration signal using intensity demodulation method. In order to measure strain and vibration of the composite main wing model under static loading a real time monitoring program was developed. Also using intensity demodulation of CWDM, sensitivity and resolution at high frequency vibration were evaluated.

  • PDF

Analysis of the Vibration of High Speed Trains and the Irregularity of Railway Using a Wavelet-based Frequency Response Function (웨이브렛 기반 주파수 응답함수를 이용한 고속철도차량의 진동 및 궤도불규칙 특성 분석)

  • Lee, Jun-Seok;Choi, Sung-Hoon;Kim, Sang-Soo;Park, Choon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.766-771
    • /
    • 2008
  • In this paper, the vibration of high speed trains and the irregularity of railway are examined using a wavelet-based frequency response function. To investigate their characteristics, non-stationary acceleration data are acquired and processed using the wavelet transform. Also, the railway irregularity is examined by acquiring the data from the on-board laser-based measurement system. The correlation between the train vibration and the railway irregularity has been investigated. From the analysis, the wavelet-based frequency response function is a promised method for the dynamic characteristics of high speed trains.

  • PDF

Forced Vibration of Car Seat and mannequin System (자동차 시트 및 마네킹 시스템의 강제 진동)

  • Kim, Seong-Geol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.122-132
    • /
    • 2000
  • A simplified modeling approach of forced vibration for occupied car seats was demonstrated by using a mathematical model presented in 'Free Vibration of Car seat and Mannequin System' nonlinear and linear equations of motions were rederived for forced vibration and the transfer function was used to calculate the frequency response function. The experimental apparatus were set up and hydraulic shaker was used to obtain the system responses. Through the tests mannequin's head had a lot of problems and the responses with a head and without a head were measured. To explore the effects of linear dampings and friction moments at the joints linear analyses were performed. New sets of linear spring and damping coefficients and torsional dampings at the joints were calculated through parameter study to match up with experimental results. Good agreement between experimental and simulation frequency response estimates were obtained both in terms of locations of resonances and system deflection shapes at resonance indicating that this is a feasible method of modeling seated occupants.

  • PDF

Frequency-Phase Method to Measure Material Damping in a Nonlinear Range (비선형 영역에서의 재료감쇠비 측정을 위한 주파수-위상각법)

  • 우규석;조성호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.533-540
    • /
    • 2001
  • Material damping is an important parameter to evaluate the site response by a dynamic loading. Currently the material damping of the subgrade is mainly determined by a resonant column testing. Typical methods to evaluate material damping include half-power bandwidth method and free-vibration decay method. In the large strain range, the half-power bandwidth method gives an erratic damping factor, because the method is based on the assumption of the linear behavior of a specimen. The free-vibration decay method has also limitations in that the damping factors vary with the range of cycles in calculation, and also in that the specific shear strain can not be designated for the free vibration. In this study, the frequency-phase method, which was developed to evaluate material damping of a beam simply supported, is introduced to evaluate the material damping by the resonant column testing. Also, the comparison among half-power method, free-vibration decay method and the frequency-phase method is provided for a remolded sand.

  • PDF

Noise and Vibration Characteristics by Heavy-weight Floor Impact (중량바닥충격에 의한 소음 및 진동 특성)

  • 서상호;송희수;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.919-922
    • /
    • 2003
  • The correlation between noise and vibration by a heavy-weight floor impact was studied. The triggering technique was used for increasing the reliability and stability to measure the level of sound pressure, sound intensity and vibration acceleration. The simple finite element and rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The result show that the isolation material adapted to reduce the light-weight floor impact noise, causing the natural frequency lower, make resonance with dominant driving frequency, and increase the noise level very sharply. Therefore the noise level Peak in the region of low frequency, below 63Hz, would be related with the natural frequencies of the floor system.

  • PDF

A study on natural frequency estimation of modified ship structure by using FRF synthesis method (전달함수함성법을 이용한 선박구조변경시 고유진동수 추정에 관한 연구)

  • Kim, Kuk-Su;Choi, Su-Hyun;Jo, Sung-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.176-180
    • /
    • 2006
  • When the vibration troubles occur on the ship structure during the sea trial, the rectification work is very restricted because of in-situ limitation. Usually, the finite element method is used to improve vibration characteristics of the structure, but it takes lots of time and effort in modeling the structure and adjusting the finite element model in order to consider appropriate boundary conditions of a complex ship structure. Therefore, experimental methods have been in general suggested to obtain proper countermeasures without time-consuming in modeling. In this paper, FRE(frequency response function) synthesis method is applied to estimate natural frequency of the modified ship structure, which is obtained from experimental and numerical methods.

  • PDF

Study on Optimum Design Condition for Variable Speed Control of Rated Speed Fans used in a Power Plant (발전소 통풍계통의 가변속 운전을 위한 최적 설계조건에 관한 연구)

  • Cho, C.W.;Yang, K.H.;Jung, N.K.;Kim, B.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.30-35
    • /
    • 2010
  • Recently, the large capacity draft fans in power plants had been changed to variable speed type to educe the power consumption. But the fan experienced the unexpected vibration at specific speed regions. In this study, the high vibration frequency of the fan was confirmed and the natural frequency of the rotor were measured and analyzed by FEM programs. It was analyzed that the vibration was caused by the resonance at the frequency, 30.7Hz. So, the rotor vibration characteristic was changed by adjusting the distance between the shaft bearings. It was conformed the high vibration was disappeared over the all operation speeds.

Evaluation on Vibration Characteristics of an Apartment Building Structure (아파트 구조물의 진동특성 평가에 관한 연구)

  • Choi, Chang-Sik;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.161-167
    • /
    • 1998
  • A problem of frequency in the field of low-frequencies such as high-rise apartment building or construction vibration are often found. In this study, damage reason of a 25 stories apartment building was searched on the basis of actual damage. To find the damage reason, structural design procedure were reviewed and low-frequency vibration test was conducted. The results indicate that the main damage reason is not by the low-frequency vibration but the asymmetrical plan of that building.

  • PDF

Frequency-shaped Sliding Mode Control of Isolation Table Equipped with Precision devices (정밀기기가 탑재된 방진대의 주파수성형 슬라이딩모드 제어)

  • 김효준;박영필
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.2
    • /
    • pp.124-131
    • /
    • 2002
  • This paper presents the design of an active vibration suppression controller for an air-spring type vibration isolation table. Firstly, isolation system model is constructed considering the isolation table, attached equipment and voice-coil actuator. An active control system is designed based on frequency-shaped sliding mode control theory rewarding high frequency uncertainties with respect to attached equipments on the isolation table. Finally. the performance of the active isolation system is evaluated by simulation under some disturbance conditions which are transmitted from base structure of the isolation system.