• Title/Summary/Keyword: Vibration assessment

Search Result 627, Processing Time 0.031 seconds

Design of railway noise and vibration Database considering noise source of railway noise complaints focused area (철도 소음 민원 집중 지역의 소음 발생원을 고려한 철도 소음진동 데이터베이스 설계)

  • Lee, Hong-gi;Lee, Hyun-jun;Son, Sung-wan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.812-816
    • /
    • 2014
  • Recently, there is an increasing interest on railway noise and vibration. Accordingly, the importance of technology that can assess the vibration and structural noise caused due to the railway operation is increasing. Additionally, the need to construct a railway noise and vibration database which is a basic data for a reliable railway noise and vibration assessment as well is increasing. However, the problem is that the currently constructed database fails to include the factors influencing the occurrence of noise and vibration sufficiently. Therefore, In this paper, design a railway noise and vibration database that includes those factors sufficiently and which enables the continuous data management and accumulation.

  • PDF

Comprehensive Vibration Assessment Program for Yonggwang Nuclear Power Plant Unit 4

  • Huinam Rhee;Hwang, Jong-Keun;Kim, Tae-Hyung;Kim, Jung-Kyu;Song, Heuy-Gap;Kim, Beom-Shig
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.1001-1007
    • /
    • 1995
  • A Comprehensive Vibration Assessment Program (CVAP) has been performed for Yonggwang Nuclear Power Plant Unit 4 (YGN 4) in order to verify the structural integrity of the reactor internals for flow induced vibrations prior to commercial operation. The theoretical evidence for the structural integrity of the reactor internals and the basis for measurement and inspection are provided by the analysis. Flow induced hydraulic loads and reactor internals vibration response data were measured during pre-core hot functional testing in YGN 4 site. Also, the critical areas in the reactor internals were inspected visually to check any existence of structural abnormality before and after the pre-core hot functional testing. Then, the measured data have been analyzed and compared with the predicted data by analysis. The measured stresses are less than the predicted values and the allowable limits. It is concluded that the vibration response of the reactor internals due to the flow induced vibration under normal operation is acceptable for long term operation.

  • PDF

Comprehensive Vibration Assessment Program Measurement Test Plan for Advanced Power Reactor 1400 (신형경수로 1400 종합진동평가프로그램 측정시험 계획)

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.589-595
    • /
    • 2013
  • A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being verified on the integrity of RVI for the design life of the plant by performing the non-prototype category-2 type on the US Nuclear Regulatory Commission Guide(NRC RG) 1.20, for which consists of a vibration and stress analysis program, a limited vibration measurement program, an inspection program, and the correlation of these programs. The aim of this paper is to describe the plan for the vibration measurement, test and acceptance criteria portion, and documentation and results of the APR1400 RVI CVAP. We will conduct the limited vibration measurement program of the APR1400 RVI CVAP according to the measurement plan and the vibration measurement testing in this paper.

  • PDF

Vibration Isolation of Wave Barriers Constructed Near a Shallow Tunnel (저심도 터널과 인접한 방진벽의 지반진동 저감효과)

  • Yang, Sin-Chu
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.567-577
    • /
    • 2015
  • This paper presents an assessment method of the ground vibration level with a combination of measured data and an analytic method. The basic concept of the method is similar to that in FRA(Federal Railway Administration) manual for detailed vibration analyses. However, going into detail, the assessment method was modified for a feasible evaluation of the vibration reduction effects of diverse types of wave barriers. The force density was evaluated in a vehicle-track interaction analysis and the transfer mobility of vibration was analyzed through a 2-D ground vibration analysis. The calculated 2-D transfer mobility was corrected to incorporate transfer characteristics of actual ground vibration by comparing the previously measured data and analysis results. Nine types of vibration reduction effects of wave barriers were analyzed on a shallow tunnel section of an urban railway where numerous civil complaints had actually been filed.

Measurement and Assessment of Whirling Vibration using Strain Gage in Small Propulsion Shafting System (소형추진축계에서 스트레인 게이지를 이용한 휘둘림 진동에 대한 계측 및 평가)

  • Kim, Jin-Hee;Kim, June-Sung;Kim, Tae-Un;Lee, Don-Chool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.527-532
    • /
    • 2011
  • Whirling vibration in severe cases may result in shaft cracking and typically gap sensors are utilized to confirm its values under the outside underwater of ship. The bending stress value causing whirling vibration on the propulsion shafting system of a 40-ton small vessel was verified by theoretical analysis and its vibration measurement. However, because of underwater condition, the accuracy for this measurement method is presumed low. In this study, the strain gauge basic principle and the bending stress calculation method are considered. The relationships are then applied for obtaining the whirling vibration of the 40-ton small vessel. As a result, a new method in estimation of whirling vibration is reached and suggested.

  • PDF

A novel computer vision-based vibration measurement and coarse-to-fine damage assessment method for truss bridges

  • Wen-Qiang Liu;En-Ze Rui;Lei Yuan;Si-Yi Chen;You-Liang Zheng;Yi-Qing Ni
    • Smart Structures and Systems
    • /
    • v.31 no.4
    • /
    • pp.393-407
    • /
    • 2023
  • To assess structural condition in a non-destructive manner, computer vision-based structural health monitoring (SHM) has become a focus. Compared to traditional contact-type sensors, the advantages of computer vision-based measurement systems include lower installation costs and broader measurement areas. In this study, we propose a novel computer vision-based vibration measurement and coarse-to-fine damage assessment method for truss bridges. First, a deep learning model FairMOT is introduced to track the regions of interest (ROIs) that include joints to enhance the automation performance compared with traditional target tracking algorithms. To calculate the displacement of the tracked ROIs accurately, a normalized cross-correlation method is adopted to fine-tune the offset, while the Harris corner matching is utilized to correct the vibration displacement errors caused by the non-parallel between the truss plane and the image plane. Then, based on the advantages of the stochastic damage locating vector (SDLV) and Bayesian inference-based stochastic model updating (BI-SMU), they are combined to achieve the coarse-to-fine localization of the truss bridge's damaged elements. Finally, the severity quantification of the damaged components is performed by the BI-SMU. The experiment results show that the proposed method can accurately recognize the vibration displacement and evaluate the structural damage.

A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

Structural Response Analysis on Inner Barrel Assembly Top Plate of APR1400 Reactor Vessel (APR1400 원자로 내부배럴집합체 상부판 구조응답해석)

  • Kim, Kyu-Hyung;Ko, Do-Young;Kim, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.907-910
    • /
    • 2012
  • Since the inner barrel assembly of the Advanced Power Reactor 1400 reactor vessel is a new design feature introduced instead of CEA(control element assembly) shroud assembly, the inner barrel assembly can be a significant object of structural integrity assessment. This paper covers the structural responses of top plate, which is a component of the inner barrel assembly, against the deterministic hydraulic load induced by pump pulsation and the random hydraulic load induced by turbulence of coolant. The top plate responds to the deterministic hydraulic load more than to the random hydraulic load and shows enough structural integrity. The results of this paper will be important basis for the selection of instruments and measurement location.

  • PDF

Sound Quality Evaluation of Vehicle Interior Noise Using Virtual Sound Quality Analysis (가상 음질 분석을 이용한 자동차 실내소음 음질 평가)

  • Kang, Sang-wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.100-106
    • /
    • 2017
  • Sound quality engineering in automobile noise applications has become more and more important under the current quiet driving condition because various noise components masked under high noise level can be audible in quieter driving situation. Many researches have been carried out for subjective and objective assessments on automobile sounds and noises. In particular, the interior sound quality has been one of research fields that can give high-quality feature to automobile products. Although many works related to the interior sound quality have been progressed or completed in foreign countries, limited research results are presented in the country. In the study, subjective assessments are first performed with 20 subjects to select perceptual adjectives suitable to the assessment of car interior noises during acceleration. The selected perceptual adjectives are employed as the assessment scales to evaluate the acceleration noises in questionnaire procedures using 35 subjects, for which several noises are created through digital filtering of the acceleration noises measured. Mean values and standard deviations for subjective assessment scores obtained by the questionnaire procedures are calculated and their reliability are also verified. Finally, various statistical analyses such as the correlation analysis and the factor analysis are carried out to reveal the interrelationship between the assessment scales and the spectrum components of the acceleration noises.

Acoustic Amenity Factor of Urban Environmental Sound for the Ecological Soundscape (도시 환경음의 쾌적성 평가요인에 관한 연구)

  • Kook, Chan;Song, Min-Jeong;Shin, Hoon;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.428-436
    • /
    • 2006
  • The assessment of an urban site depends on the way whether it responds to multiple needs such as functionality, aesthetic and complex comfort of acoustic, thermal, lighting and air quality etc. This study aims to investigate the assessment of various urban soundscapes in the sense of acoustic amenity by the questionnaires. As a result, acoustic amenity assessment was influenced by the non-acoustic factors such as environment assessment of visual, thermal, air quality etc. In the sense of sound quality, urban environmental sound was interpreted as 3 factors of strength, evolution of time, spacial localization. So these factors would be considered in the new assessment method for acoustic amenity. And it was shown that the subjects tend to perceive the noise level less than $3{\sim}5dB\;L_{eqA}$ according to the urban landscapes under the similar noise exposure level.