• 제목/요약/키워드: Vibration Time Analysis

검색결과 1,522건 처리시간 0.024초

Structural health monitoring of a cable-stayed bridge using wireless smart sensor technology: data analyses

  • Cho, Soojin;Jo, Hongki;Jang, Shinae;Park, Jongwoong;Jung, Hyung-Jo;Yun, Chung-Bang;Spencer, Billie F. Jr.;Seo, Ju-Won
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.461-480
    • /
    • 2010
  • This paper analyses the data collected from the $2^{nd}$ Jindo Bridge, a cable-stayed bridge in Korea that is a structural health monitoring (SHM) international test bed for advanced wireless smart sensors network (WSSN) technology. The SHM system consists of a total of 70 wireless smart sensor nodes deployed underneath of the deck, on the pylons, and on the cables to capture the vibration of the bridge excited by traffic and environmental loadings. Analysis of the data is performed in both the time and frequency domains. Modal properties of the bridge are identified using the frequency domain decomposition and the stochastic subspace identification methods based on the output-only measurements, and the results are compared with those obtained from a detailed finite element model. Tension forces for the 10 instrumented stay cables are also estimated from the ambient acceleration data and compared both with those from the initial design and with those obtained during two previous regular inspections. The results of the data analyses demonstrate that the WSSN-based SHM system performs effectively for this cable-stayed bridge, giving direct access to the physical status of the bridge.

Continuous force excited bridge dynamic test and structural flexibility identification theory

  • Zhou, Liming;Zhang, Jian
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.391-405
    • /
    • 2019
  • Compared to the ambient vibration test mainly identifying the structural modal parameters, such as frequency, damping and mode shapes, the impact testing, which benefits from measuring both impacting forces and structural responses, has the merit to identify not only the structural modal parameters but also more detailed structural parameters, in particular flexibility. However, in traditional impact tests, an impacting hammer or artificial excitation device is employed, which restricts the efficiency of tests on various bridge structures. To resolve this problem, we propose a new method whereby a moving vehicle is taken as a continuous exciter and develop a corresponding flexibility identification theory, in which the continuous wheel forces induced by the moving vehicle is considered as structural input and the acceleration response of the bridge as the output, thus a structural flexibility matrix can be identified and then structural deflections of the bridge under arbitrary static loads can be predicted. The proposed method is more convenient, time-saving and cost-effective compared with traditional impact tests. However, because the proposed test produces a spatially continuous force while classical impact forces are spatially discrete, a new flexibility identification theory is required, and a novel structural identification method involving with equivalent load distribution, the enhanced Frequency Response Function (eFRFs) construction and modal scaling factor identification is proposed to make use of the continuous excitation force to identify the basic modal parameters as well as the structural flexibility. Laboratory and numerical examples are given, which validate the effectiveness of the proposed method. Furthermore, parametric analysis including road roughness, vehicle speed, vehicle weight, vehicle's stiffness and damping are conducted and the results obtained demonstrate that the developed method has strong robustness except that the relative error increases with the increase of measurement noise.

Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge

  • Zahrai, Seyed Mehdi;Froozanfar, Mohammad
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.449-466
    • /
    • 2019
  • Cable-stayed bridges are attractive due to their beauty, reducing material consumption, less harm to the environment and so on, in comparison with other kinds of bridges. As a massive structure with long period and low damping (0.3 to 2%) under many dynamic loads, these bridges are susceptible to fatigue, serviceability disorder, damage or even collapse. Tuned Mass Damper (TMD) is a suitable controlling system to reduce the vibrations and prevent the threats in such bridges. In this paper, Multi Tuned Mass Damper (MTMD) system is added to the Ahvaz cable stayed Bridge in Iran, to reduce its seismic vibrations. First, the bridge is modeled in SAP2000 followed with result verification. Dead and live loads and the moving loads have been assigned to the bridge. Then the finite element model is developed in OpenSees, with the goal of running a nonlinear time-history analysis. Three far-field and three near-field earthquake records are imposed to the model after scaling to the PGA of 0.25 g, 0.4 g, 0.55 g and 0.7 g. Two MTMD systems, passive and active, with the number of TMDs from 1 to 8, are placed in specific points of the main span of bridge, adding a total mass ratio of 1 to 10% to the bridge. The parameters of the TMDs are optimized using Genetic Algorithm (GA). Also, the optimum force for active control is achieved by Fuzzy Logic Control (FLC). The results showed that the maximum displacement of the center of the bridge main span reduced 33% and 48% respectively by adding passive and active MTMD systems. The RMS of displacement reduced 37% and 47%, the velocity 36% and 42% and also the base shear in pylons, 27% and 47%, respectively by adding passive and active systems, in the best cases.

펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정 (Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.111-116
    • /
    • 2022
  • 전동기 소손의 원인으로는 과부하, 결상, 구속, 층간단락, 권선의 지락, 순간과전압의 유입, 회전자가 고정자에 닿는 경우 등 절연파괴로 이어져 고장 또는 전기 사고로 이어지고 있다. 따라서 기기 고장은 기기의 보수/수리에 필요한 비용에 의한 손실뿐만 아니라, 전동기가 포함된 공정 자체를 멈추기 때문에 공정 정지에 따른 생산성 저하에 의한 막대한 경제적 손실을 초래한다. 전동기의 고장을 진단하기 위한 현재의 기술의 수준은 진동, 열, 전력분석 방식을 이용하고 있지만, 고장에 따른 상당 부분의 시간이 진행되어야 문제점을 분석할 수 있는 한계점을 가지고 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 DC AMP 신호를 이용하여 절연저항을 측정하는 장치 및 알고리즘을 산업용 전동기에 적용하여 절연저항 상태값을 추종하여 기존방식에서 해결되지 못한 전동기의 열화 및 고장 진단을 제안한다.

Galloping characteristics of a 1000-kV UHV iced transmission line in the full range of wind attack angles

  • Lou, Wenjuan;Wu, Huihui;Wen, Zuopeng;Liang, Hongchao
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.173-183
    • /
    • 2022
  • The galloping of iced conductors has long been a severe threat to the safety of overhead transmission lines. Compared with normal transmission lines, the ultra-high-voltage (UHV) transmission lines are more prone to galloping, and the damage caused is more severe. To control the galloping of UHV lines, it is necessary to conduct a comprehensive analysis of galloping characteristics. In this paper, a large-span 1000-kV UHV transmission line in China is taken as a practical example where an 8-bundled conductor with D-shaped icing is adopted. Galerkin method is employed for the time history calculation. For the wind attack angle range of 0°~180°, the galloping amplitudes in vertical, horizontal, and torsional directions are calculated. Furthermore, the vibration frequencies and galloping shapes are analyzed for the most severe conditions. The results show that the wind at 0°~10° attack angles can induce large torsional displacement, and this range of attack angles is also most likely to occur in reality. The galloping with largest amplitudes in all three directions occurs at the attack angle of 170° where the incoming flow is at the non-iced side, due to the strong aerodynamic instability. In addition, with wind speed increasing, galloping modes with higher frequencies appear and make the galloping shape more complex, indicating strong nonlinear behavior. Based on the galloping amplitudes of three directions, the full range of wind attack angles are divided into five galloping regions of different severity levels. The results obtained can promote the understanding of galloping and provide a reference for the anti-galloping design of UHV transmission lines.

로드헤더 장비사양 검토 및 굴착효율 예측 모델 개발 (Development of roadheader performance prediction model and review of machine specification)

  • 정재훈;임주휘;이재원;강한별;김도훈;신영진
    • 한국터널지하공간학회 논문집
    • /
    • 제25권3호
    • /
    • pp.221-243
    • /
    • 2023
  • 국내 도심지 터널 공사에서 발파로 인한 진동 및 소음 방지를 위한 대안으로 로드헤더 공법 적용사례가 늘고 있다. 그러나 국내의 암반 대상 로드헤더 적용사례가 극히 적어 로드헤더 장비선정과 굴착효율 평가에 한계가 있다. 특히 로드헤더 굴착효율 평가를 위해 현재는 해외 현장에서 경험적으로 개발된 모델식을 적용하고 있으나 국내 암종 및 지질조건에 대한 검증이 부족한 실정이다. 본 연구에서는 해외 문헌 연구를 통하여 로드헤더 장비사양 결정방법과 굴착효율 평가 모델을 조사하였다. 이를 바탕으로 국내 현장 대상 장비선정을 위한 사양 검토와 더불어 현장 대상 암석강도와 굴착효율의 상관모델식을 제안하고 설계 굴착효율 예측 모델과 비교하였다. 또한 로드헤더 절삭이론 모델식을 이용한 굴착효율 산정의 간편법을 제안함으로써 굴착효율을 평가하고 기존 경험적 예측 모델과 비교 검증하였다.

외부 유체와 연성된 도파관의 진동 및 소음 해석 기법 (A Numerical Method for Analysis of the Sound and Vibration of Waveguides Coupled with External Fluid)

  • 유정수
    • 한국음향학회지
    • /
    • 제29권7호
    • /
    • pp.448-457
    • /
    • 2010
  • 단면의 형상이 길이방향으로 일정한 무한길이 도파관 구조물 (waveguide structures)에 대한 진동 및 파동전파 특성은 도파관유한요소법 (waveguide finite element method, WFEM)을 이용해 효과적으로 해석할 수 있다. 도파관유한요소법은 2차원 단면만을 FE 모델링하여 해석하므로 모델의 크기가 작고 연산시간이 짧다는 장점이 있다. 도파관 구조물이 외부 유체와 연성된 경우, 원통형 실린더 또는 파이프와 같이 단면의 형상이 단순한 경우에는 이론적 해석을 수행할 수 있다. 반면 복잡한 형상의 단면을 가진 도파관구조물이 유체와 연성된 경우에는 수치해석 방법이 요구된다. 외부 유체와 연성된 도파관 구조물은 외부 유체와 도파관유한요소 (WFE)를 연성시켜 해석하는 수치해석 방법을 고려할 수 있다. 본 논문에서는 외부 유체 모델링에 경계요소 (Boundary Element)를 도입하고 이를 도파관유한요소와 연성시킨 WFE/BE 방법을 소개한다. 이 방법의 적용 예로써 단순형상의 파이프에 대해 외부 유체의 유/무에 따른 분산선도와 가진점 모빌리티 (point mobility)를 구하고 이를 이론해석 결과와 비교하였다. 또한 WFE/BE 방법을 이용해 파이프에서 외부 유체로 방사되는 음향파워를 구하고 접수 유/무에 따른 영향을 살펴보았다.

신설 터널 발파 시 기존 터널 거동 및 시설물 안전에 관한 연구 (A Study on the Behavior of an Existing Tunnel and the Safety Implications on its Facilities from a New Tunnel Blasting)

  • 김성훈;조원철
    • 한국재난관리표준학회지
    • /
    • 제3권2호
    • /
    • pp.57-64
    • /
    • 2010
  • 본 연구는 신설 터널 발파 시 기존 터널 거동 및 시설물 안전에 관한 연구로서 설계 당시에는 신설 터널의 안전성에 초점을 맞추다 보니 기존 터널 내부에 설치되어 있는 제연 팬 등과 같이 시설물의 안전성을 확보하기 위한 세부적인 설계에 있어서 다소 미흡한 면이 있었다. 기존 터널의 최근 10년간 교통사고 유형을 분석한 결과 주행 중인 차량 간 긴급 상황 및 상호 장애요소 발생 시 미처 대처하지 못해 발생하는 사고가 대부분인 것을 알 수 있었다. 이런 점을 감안하여 신설 터널 시점 부 및 본선 구간 발파 시 장약량을 최소화하였고 피난연결통로 굴착은 대구경 심빼기 발파공법으로 변경 시공하여 진동을 최소화함으로써 기존 터널 내부의 시설물 안전성을 확보하였다. 정량적 분석 방법으로서는 각종 계측기를 설치하여 신설 터널 주변 민가, 기존 터널 내부 및 제연 팬 주위에 설치하여 실시간 변위를 파악하여 교통류 차단 없이 정상 흐름을 확보하였다. 향후 대도심지에 위치하면서 기존 터널과 인접한 터널 설계 시 터널 내부 시설물 안전성 확보를 위해 발파 장약량, 발파공법 및 계측방법의 개선 방안을 제시하였다.

  • PDF

교회공간 예배실의 위치적 기능에 따른 마감재 적용 연구 (A Study on the Application of Finishing Materials According to the Locational Function of the Chapel in Church Space)

  • 여미;이창노
    • 한국실내디자인학회논문집
    • /
    • 제24권1호
    • /
    • pp.178-188
    • /
    • 2015
  • This study has the main objective of being of help as a reference data for the application of the finishing materials when designing the interior of the chapel of the church space through analysis of the finishing materials against the chapels of church space which has complex function. As precedent studies for this, the composition of the function and concept of the church space was surveyed and the complex function of the church space was surveyed. The theoretical surveyed was performed according to the casual composition, behavior of the community and role and location of the duties of the church members. The case objects were 10 chapels constructed by 5 professional interior design companies. The content of the analysis was the finishing materials in the chapels and their application characteristics. The detailed considerations to be referred to when designing the interior of the chapels of church space in the future were proposed. The analysis result of the application of the finishing materials according to the locational function of the chapels of church space can be explained as follows. First, the platform area was the characteristic of applying finishing materials which induce visual immersion. As for the floor materials in the platform, in order to minimize the floor sound and vibration phenomenon occurring during movements, noise insulation and dust protection rubber sheet was place and on top of it the floor or the carpet was placed. Second, the Choir area had the difficult problem of having to consider the appropriate sound absorption occurring due to the proliferation of sound and performance of classical instruments at the same time. However, in the case, this problem was solved through the sculptures of convex shape. Third, since the scheelite is a space where many people move around, the finishing material which absorbs sound was mainly used. Fourth, the entrance area was composed of thick wall materials compared to other walls, and the sound absorption character was most significantly considered when applying the finishing material. Fifth, the broadcasting room was composed either in independent type or an open type and performed its function and the main finishing materials was transparent glass which was highest use frequency.

CARSIM- Simulink연동 해석을 이용한 전자기 현가장치의 상대변위 해석 (Analysis of relative displacement of electromagnetic suspension using CARSIM and Simulink)

  • 김지혜;김진호
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.82-88
    • /
    • 2018
  • 본 논문에서는 차량 주행 시 노면으로부터 진동 에너지를 흡수해 에너지 하베스팅을 통해 전기에너지 발생이 가능한 전자기 현가장치의 구조와 현가장치 내에 결합되어 전자기 댐퍼 역할을 하는 8극 8상의 선형 발전기의 구조를 검토하였다. 실제 주행 노면에 따른 전자기 현가장치의 에너지 하베스팅 효과를 비교하기 위해 차량 시뮬레이션 프로그램인 Carsim과 Simulink를 연동하여 민군 겸용 차량 모델을 사용해 두 가지 실제 노면인 아스팔트 노면과 비포장도로 노면 조건에 대한 모의 주행시험을 수행한 결과, 아스팔트 노면과 비포장도로에서 현가장치의 상대 변위 각각 8mm, 13mm의 결과가 나타났다. 다음으로 전자기 현가장치 내에 결합된 선형 발전기를 모델링 하여 도출한 현가장치 상대 변위 값을 적용해 상용 전자기 해석 프로그램인 ANSYS MAXWELL을 이용해 동일한 해석조건을 적용하여 해석 시간 0.3s 동안 전자기 시뮬레이션을 수행하여 시간에 따른 발전량 결과를 도출해 비교하였으며 비포장도로와 아스팔트 노면에서의 평균 발전량은 각각 198.6W, 98.7W로 비포장도로의 경우 103.7% 높은 값을 보이는 것을 확인하였다. 마지막으로 노면의 주파수와 현가장치 입력 변위가 발전 출력에 영향을 끼치는 민감도를 비교한 결과 두 변수의 민감도는 각각 1.725, 1.283으로 노면 주파수가 전자기 시뮬레이션 출력변수인 평균 발전량에 34.5 % 높은 영향을 끼치는 결과를 확인하였다.