• 제목/요약/키워드: Vibration Stimulation

검색결과 102건 처리시간 0.038초

Effect of audio distraction with thermomechanical stimulation on pain perception for inferior alveolar nerve block in children: a randomized clinical trial

  • Devendra Nagpal;Dharanshi Viral Amlani;Pooja Rathi;Kavita Hotwani;Prabhat Singh;Gagandeep Lamba
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권6호
    • /
    • pp.327-335
    • /
    • 2023
  • Background: Pain control is a crucial aspect of pediatric dentistry for patient management. Thermo-mechanical devices (BuzzyTM Pain Care Labs, USA) work on the concept of vibration and cooling and have shown promising results in pain control during local anesthesia in pediatric dentistry. On the other hand, audio distraction has also been used for pain management. The amount of pain endured is determined by the patient's perception and attentiveness. Thus, if audio function is added to the thermomechanical device it might increase its efficiency. Hence, the present study aimed to compare pain on injection using a thermo-mechanical device with and without audio during inferior alveolar nerve block (IANB) injection in children aged 5-10 years old. Methods: Twenty-eight children aged between 5 and 10 indicated for IANB were included in this randomized study. Children who were undergoing the dental procedure were divided into 2 groups, with 14 children in each group. The study group was the thermo-mechanical device with audio distraction; the control group was the thermo-mechanical device without audio distraction. IANB was administered. Subjective pain evaluation was performed using the Wong-Baker Faces Pain Rating Scale (WBFPR) and objective pain evaluation was done using the Faces, Leg, Activity, Consolability, Cry (FLACC) scale. Results: The outcome depicted a significant reduction in pain on injection for both objective and subjective evaluations in the thermo-mechanical device with an audio distraction group. Conclusions: Less pain on injection was observed, when a thermo-mechanical device was used with audio distraction for IANB procedures.

모바일 기기를 위한 진동촉각 디스플레이와 선호하는 패턴 생성방법 (A Vibrotactile Display for Hand-held Devices and Its Preferable Pattern Generation Method)

  • 양기훈;진연섭;강성철
    • 제어로봇시스템학회논문지
    • /
    • 제20권8호
    • /
    • pp.795-800
    • /
    • 2014
  • In this paper, a vibrotactile pad system, T-mobile, is developed to provide vibrotactile cues for hand-held devices. A grooved and slim design is adapted to the back-side plane of the T-mobile, and the contact part consists of 12 vibrotactile panels which can operate independently and separately. To be isolated among vibrotactile actuators, the surface of the cover is divided into several pieces. Each vibrating module consists of a linear resonant actuator, a section of covering surface, and a vibration isolator. In order to provide spatial and directional information, sensory saltation and phantom sensation are applied to the T-mobile. To evaluate the developed device, two experiments were conducted to test whether directional information and spatial information can be successfully displayed by the device. Additionally, in order to find optimal stimulation by sensory saltation, an empirical test was conducted. As a result, spatial and directional information would be useful for displaying intuitive information for hand-held devices with vibrotactile feedback and reasonable near-optimal value for sensory saltation was obtained.

Light intensity controlled wrinkling patterns in photo-thermal sensitive hydrogels

  • Toh, William;Ding, Zhiwei;Ng, Teng Yong;Liu, Zishun
    • Coupled systems mechanics
    • /
    • 제5권4호
    • /
    • pp.315-327
    • /
    • 2016
  • Undergoing large volumetric changes upon incremental environmental stimulation, hydrogels are interesting materials which hold immense potentials for utilization in a wide array of applications in diverse industries. Owing to the large magnitudes of deformation it undergoes, swelling induced instability is a commonly observed sight in all types of gels. In this work, we investigate the instability of photo-thermal sensitive hydrogels, produced by impregnating light absorbing nano-particles into the polymer network of a temperature sensitive hydrogel, such as PNIPAM. Earlier works have shown that by using lights of different intensities, these hydrogels follow different swelling trends. We investigate the possibility of utilizing this fact for remote switching applications. The analysis is built on a thermodynamic framework of inhomogeneous large deformation of hydrogels and implemented via commercial finite element software, ABAQUS. Various examples of swelling induced instabilities, and its corresponding dependence on light intensity, will be investigated. We show that the instabilities that arise have their morphologies dependent on the light intensity.

휴대폰을 통한 음향 및 진동자극이 인체의 감성에 미치는 영향 평가 (A Estimation of Emotional Sensibility by that Music and Vibration Stimulation of the Cellular Phone)

  • 김민호;김기범;김승우;오동익;김동욱
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2005년도 춘계학술발표논문집
    • /
    • pp.111-114
    • /
    • 2005
  • 현재 휴대폰은 대중화되고 있으며, 로봇기술 또한 각광 받고 있다. 그래서 우리는 로봇기술과 휴대폰 기술을 접목한 RCP(Robotic Cellular Phone)를 구현하려 한다. RCP를 구성하기 위해서 휴대폰의 움직임을 구현, 외부환경 및 RCP 자신의 상태인식 기능 그리고 사용자의 감성을 유발할 수 있는 감성유발엔진 및 감성평가모델의 군축이 필요하다. 본 연구에서는 감성평가모델의 개발을 위하여 음악과 진동 자극을 주어 생체신호 HRV와 GSR을 측정하여 정량적인 데이터를 수집, 특정감성을 평가하였다. 감성을 평가함에 있어서 개인의 차이가 발생하기 때문에 개개인의 표준화 (Normalize)가 필요하게 되었다. 표준화를 위하여 IAPS영상을 활용한 결과 우리가 얻고자 하는 감성의 변화에 대한 판단을 할 수 있음으로 감성의 신호 모델을 유추할 수 있었다.

  • PDF

마우스형 통합 질감 제시 시스템 개발 (Development of an Integrated Mouse Type Tactile Display System)

  • 경기욱;손승우;양기훈;김문상;권동수
    • 제어로봇시스템학회논문지
    • /
    • 제11권5호
    • /
    • pp.445-450
    • /
    • 2005
  • In this paper, we suggest an integrated tactile display system that provides kinesthetic force, pressure distribution, vibration and slip/stretch. The system consists of two parts: a 2 DOF force feedback device for kinesthetic display and a tactile feedback device for displaying the normal stimulation to the skin and the skin slip/stretch. Psychophysical experiments measure the effects of fingerpad selection, the direction of finger movements and the texture width on tactile sensitivity. We also investigate the characteristics of lateral finger movement while subjects perceive different textures. From the experimental results, the principal parameters for designing a tactile display are suggested. A tactile display device, using eight piezoelectric bimorphs and a linear actuator, Is implemented and attached to a 2 DOF translational force feedback device to simultaneously simulate the texture and stiffness of the object. As a result, we find out that the capability of the suggested device is sufficient to display physical quantities to display the texture.

Dynamic intelligent control of composite buildings by using M-TMD and evolutionary algorithm

  • Chen, ZY;Meng, Yahui;Wang, Ruei-Yuan;Peng, Sheng-Hsiang;Yang, Yaoke;Chen, Timothy
    • Steel and Composite Structures
    • /
    • 제42권5호
    • /
    • pp.591-598
    • /
    • 2022
  • The article deals with the possibilities of vibration stimulation. Based on the stability analysis, a multi-scale approach with a modified whole-building model is implemented. The motion equation is configured for a controlled bridge with a MDOF (multiple dynamic degrees of freedom) Tuned Mass Damper (M-TMD) system, and a combination of welding, excitation, and control effects is used with its advanced packages and commercial software submodel. Because the design of high-performance and efficient structural systems has been of interest to practical engineers, systematic methods of structural and functional synthesis of control systems must be used in many applications. The smart method can be stabilized by properly controlling the high frequency injection limits. The simulation results illustrate that the multiple modeling method used is consistent with the accuracy and high computational efficiency. The M-TMD system, even with moderate reductions in critical pressure, can significantly suppress overall feedback on an unregulated design.

기능성 자기공명영상에서 진동자극에 대한 감각피질의 비선형성 (Nonlinearity in the Somatosensory Cortex Response to Vibrotactile Stimulator in fMRI)

  • 이현숙
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.159-166
    • /
    • 2006
  • 기능성 자기공명영상을 이용하여 진동자극에 대한 감각피질의 비선형성에 대하여 연구하였다. 진동자극은 25 Hz의 주파수로 5개의 각기 다른 진동 자극 기간, 2초, 4초, 8초, 12초 그리고 16초와 함께 20초의 무자극 주기와 pseudo-random순서로 구성되었다. 감각피질에 대한 자극 기간의 변화에 따른 선형성을 이해하기 위하여 두 다른 방법(시스템의 선형성 조사법과 gamma-variate 함수를 적용하여 impulse response함수를 구하는 방법)을 사용하여 혈류반응 함수를 분석하였는데, 그 결과는 거의 비슷하였다. 감각피질에서의 BOLD 반응은 8초보다 작은 자극 기간 동안에는 비선형이고 8초 이상일 때는 선형성을 보였다. 자극 기간의 함수로 Impulse response 함수의 진폭, 면적, 피크까지의 시간, FWHM을 계산하였고 진폭과 면적의 크기는 자극 기간이 증가할 때 감소함을 보여줌으로써 자극 기간 8초에서 BOLD 반응이 비선형성에서 선형성으로 변함을 뒷받침해 주었다.

  • PDF

디지털 음원의 촉각 자극 전이를 위한 미디어 플레이어에 대한 연구 (A research on the media player transferring vibrotactile stimulation from digital sound)

  • 임영훈;이수진;정종환;하지민;황민철;박준석
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2007년도 학술대회 1부
    • /
    • pp.881-886
    • /
    • 2007
  • 오감 융합 정보 시대가 도래한다. 오감 융합은 감각 정보의 전이 기술 개발로 가능하다. 본 연구는 청각 정보의 촉각 정보 전이에 대한 연구이다. WMPlayer10SDK는 마이크로소프트사의 윈도우즈 미디어 플레이어(Windows Media Player, WMP)를 전용 소프트웨어 기반으로 하는 Plug-in 개발툴이다. WMPlayer10SDK 시스템은 WMP 내에서의 비디오와 오디오의 신호 정보를 추출하는 부분을 제공한다. 이를 이용하여 촉각 디스플레이(Tactile Display)장치인 Pos Tactor를 연동하여 음성 신호에서 진동 촉각을 제시하는 시스템을 개발하였다. 음성신호는 8bit, 16bit, 24bit, 32bit로 구분되며 각각의 주파수와 음폭의 Scale을 계산하여 그 수치를 시리얼 통신을 사용하여 통신포트(COM1)에 38400bps로 전달하여 구동하게 하였다. 이를 이용하여 음악을 촉감으로 느끼는 뮤직슈트(music suit)를 개발 하였다. 그러므로 뮤직슈트의 적용된 기술은 청각적 체험을 촉각적 체험을 할 수 있는 오감 융합 기술의 기초 기술로 제공 될 수 있다.

  • PDF

자극 습관화가 자동차 경적음의 심리음향 특성에 따른 심리생리적 予분에 미치는 영향 (The influence habituation on psychophysiological differentation of automobile horns with different psychoacoustic characteristics)

  • 민윤기;;이임갑;조문재;손진훈
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.263-268
    • /
    • 1999
  • Psychoacoustic characteristics of automobile hems influence subject's subjective evaluation and psychophysiological reactions on the sounds of car horns. However, differentiation of physiological responses to commercially availablenfluence subject's subjective evaluation and psychophysiological reactions on the s horns is a complicated task due to the small contrast in technical features of horns and the influence of habituation. Using 10 college students, comparative analysis of physiological reactivity was carried out in order to identify the effect of habituation on decrement of psychophysiological responsivity, assess the ability to differentiate subjectively most and least preferred/appropriate horns according to physiological manifestations. EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials (each block was varied in order for presenting stimuli and acoustic parameters of horns). It was shown that electrodermal and cardiovascular responses had different reactivity patterns to repeated stimulation. Skin conductance variables (SCL, SCR) were habituated as a function of trial. Cardiac reactivity (HR, RSA) showed no signs of habituation. In contrast, sensitization was shown in the vascular component of response (pulse volume). The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred/appropriate horns was possible in this study. That is, some cardiovascular reactivity variables (HR, RSA, pulse volume, etc.) were differentiated between the least and the most preferred/appropriate horns during the experiment. However, EEG and electrodermal parameters showed significant differences only during first block of trials and were later affected by habituation.

  • PDF

DentalVibe versus lignocaine hydrochloride 2% gel in pain reduction during inferior alveolar nerve block in children

  • Menni, Alekhya Chowdary;Radhakrishna, Ambati Naga;Prasad, M. Ghanashyam
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.397-402
    • /
    • 2020
  • Background: Inferior alveolar nerve block (IANB) is the most common, painful, and anxiety-provoking procedure involving needle insertion for anesthetic solution deposition. DentalVibeⓇ (DV) delivers vibration at a sustained frequency as a counter-stimulation to the site of injection, thereby alleviating pain. The aim of this study was to evaluate and compare the effectiveness of DV and lignocaine hydrochloride 2% gel (Lox 2% jelly) in pain reduction during IANB in children. Methods: A split-mouth randomized clinical trial was designed with a sample of 60 children (age, 6 to 12 years) requiring bilateral IANB for various dental procedures; DV was used while administering IANB and Lox 2% jelly was used as the topical anesthetic before administering IANB at subsequent appointments. During both appointments, pain perception was measured using the sound, eye, motor (SEM) scale and Wong-Baker faces pain rating scale (WBFPRS); oxygen saturation (SpO2) and pulse rate were measured using a pulse oximeter before, during, and after the IANB procedure. The obtained values were tabulated and subjected to statistical analysis. Wilcoxon test was used for intergroup comparison, and Friedman test, for intragroup comparison of measured variables at different treatment phases. Results: The medians and interquartile ranges of the WBFPRS scores recorded during the IANB procedure for DV and Lox 2% jelly were 2 (2-4) and 2 (0-2), respectively (P < 0.05). The SEM scale scores, mean SpO2, and pulse rate did not show any significant differences during the IANB procedure between both treatments. Conclusion: Both DV and Lox 2% jelly were found to be effective in pain reduction during IANB in children.