• 제목/요약/키워드: Vibration Monitoring

검색결과 1,040건 처리시간 0.028초

Health monitoring of pressurized pipelines by finite element method using meta-heuristic algorithms along with error sensitivity assessment

  • Amirmohammad Jahan;Mahdi Mollazadeh;Abolfazl Akbarpour;Mohsen Khatibinia
    • Structural Engineering and Mechanics
    • /
    • 제87권3호
    • /
    • pp.211-219
    • /
    • 2023
  • The structural health of a pipeline is usually assessed by visual inspection. In addition to the fact that this method is expensive and time consuming, inspection of the whole structure is not possible due to limited access to some points. Therefore, adopting a damage detection method without the mentioned limitations is important in order to increase the safety of the structure. In recent years, vibration-based methods have been used to detect damage. These methods detect structural defects based on the fact that the dynamic responses of the structure will change due to damage existence. Therefore, the location and extent of damage, before and after the damage, are determined. In this study, fuzzy genetic algorithm has been used to monitor the structural health of the pipeline to create a fuzzy automated system and all kinds of possible failure scenarios that can occur for the structure. For this purpose, the results of an experimental model have been used. Its numerical model is generated in ABAQUS software and the results of the analysis are used in the fuzzy genetic algorithm. Results show that the system is more accurate in detecting high-intensity damages, and the use of higher frequency modes helps to increase accuracy. Moreover, the system considers the damage in symmetric regions with the same degree of membership. To deal with the uncertainties, some error values are added, which are observed to be negligible up to 10% of the error.

Real-time estimation of responses and loads of real-scale pipes subjected to earthquakes and external loads using digital twin technology

  • Dongchang Kim;Shinyoung Kwag;Sung-Jin Chang;Seunghyun Eem
    • Smart Structures and Systems
    • /
    • 제33권5호
    • /
    • pp.375-383
    • /
    • 2024
  • Infrastructure facilities contain various pipe systems, which can be considerably damaged by external loads such as earthquakes. Therefore, structural health monitoring (SHM) and safety assessment of pipes are crucial. Digital twin technology for SHM of pipes is important in the industry. This study proposes a digital twin system that estimates the behavior, stress, and external load of real-scale pipes in real time under simultaneous seismic and external loads using a minimum number of sensors. Vibration tests were performed to construct the digital twin system, and a numerical model was developed that considered the dynamic characteristics of a target pipe. Moreover, a reduced-order modeling technique of a numerical model was applied to enhance its real-time performance. The digital twin system successfully estimated the response of the pipe at all points. Verification of the digital twin system was performed by comparing it with the experimental parameters of a real-scale pipe. The proposed digital twin system can help enhance SHM and system's maintenance.

Refinement of damage identification capability of neural network techniques in application to a suspension bridge

  • Wang, J.Y.;Ni, Y.Q.
    • Structural Monitoring and Maintenance
    • /
    • 제2권1호
    • /
    • pp.77-93
    • /
    • 2015
  • The idea of using measured dynamic characteristics for damage detection is attractive because it allows for a global evaluation of the structural health and condition. However, vibration-based damage detection for complex structures such as long-span cable-supported bridges still remains a challenge. As a suspension or cable-stayed bridge involves in general thousands of structural components, the conventional damage detection methods based on model updating and/or parameter identification might result in ill-conditioning and non-uniqueness in the solution of inverse problems. Alternatively, methods that utilize, to the utmost extent, information from forward problems and avoid direct solution to inverse problems would be more suitable for vibration-based damage detection of long-span cable-supported bridges. The auto-associative neural network (ANN) technique and the probabilistic neural network (PNN) technique, that both eschew inverse problems, have been proposed for identifying and locating damage in suspension and cable-stayed bridges. Without the help of a structural model, ANNs with appropriate configuration can be trained using only the measured modal frequencies from healthy structure under varying environmental conditions, and a new set of modal frequency data acquired from an unknown state of the structure is then fed into the trained ANNs for damage presence identification. With the help of a structural model, PNNs can be configured using the relative changes of modal frequencies before and after damage by assuming damage at different locations, and then the measured modal frequencies from the structure can be presented to locate the damage. However, such formulated ANNs and PNNs may still be incompetent to identify damage occurring at the deck members of a cable-supported bridge because of very low modal sensitivity to the damage. The present study endeavors to enhance the damage identification capability of ANNs and PNNs when being applied for identification of damage incurred at deck members. Effort is first made to construct combined modal parameters which are synthesized from measured modal frequencies and modal shape components to train ANNs for damage alarming. With the purpose of improving identification accuracy, effort is then made to configure PNNs for damage localization by adapting the smoothing parameter in the Bayesian classifier to different values for different pattern classes. The performance of the ANNs with their input being modal frequencies and the combined modal parameters respectively and the PNNs with constant and adaptive smoothing parameters respectively is evaluated through simulation studies of identifying damage inflicted on different deck members of the double-deck suspension Tsing Ma Bridge.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구 (Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System)

  • 윤주영;성대진;신용현;이지훈;문두경;강상우
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.421-426
    • /
    • 2006
  • 화학증착 시스템의 파이프내 발생하는 오염입자의 진단을 위하여 초음파 및 진동진단법을 각각 비교, 연구하였다. 초음파 진단의 경우 파이프 외벽에 초음파 센서를 부착하여 펄스를 가한 후 에코 분석을 통해 파이프내벽의 오염입자를 관찰하였고 진동 진단의 경우 파이프외벽에 부착된 진통발생기를 통해 파이프에 인위적인 진동을 발생시켜 여기에서 발생되는 주파수 차이를 분석, 파이프내의 오염입자 여부를 관찰하였다. 초음파 진단의 경우, 오염입자가 파이프 내벽에 부착되어 있을 때는 효과가 좋았으나 오염입자가 시간이 지남에 따라 건조되어 파이프 내벽에서 떨어져 나와 파이프 내벽과 오염입자사이에 틈새가 생길 경우 초음파 펄스는 이 공간을 통과하지 못하고 파이프 내벽에서 다시 반사되어 오염입자를 진단하지 못하는 경우가 발생하였다. 따라서 초음파 진단법으로는 진공장비의 오염입자 관찰에 재현성을 보여주지 못하는 것으로 확인되었다. 반면 진동진단법의 경우 위와 같이 일정시간이 지난 동일한 샘플의 경우에서도 오염입자에 의한 차이가 관찰되었다, 즉 파이프내 오염입자가 존재시 새 파이프에 비해 진동음이 저주파대로 떨어짐이 확인되어 추후 화학증착 시스템의 파이프내 오염입자 모니터링 연구에 가장 효과적인 방법으로 기대된다.

차원 축소 진동 신호를 이용한 신경망 기반 선박 엔진 고장진단에 관한 연구 (A study on fault diagnosis of marine engine using a neural network with dimension-reduced vibration signals)

  • 심기찬;이강수;변성훈
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.492-499
    • /
    • 2022
  • 본 연구에서는 진동 신호의 차원 감소가 선박 엔진의 고장진단에 미치는 영향을 실험적으로 분석한 결과를 제시한다. 주성분 분석을 이용하여 513차원의 진동 신호를 1 ~ 15차원의 저차원 신호로 변환하여 차원 변화에 따른 고장진단 정확도의 변화를 관찰하였다. 실제 규모의 선박용 발전기 디젤 엔진에서 측정된 진동 신호를 사용하고, integrated gradients와 feature permutation 기법의 두 가지 변수 중요도 분석 알고리즘을 사용하여 차원 축소 신호의 기여도를 정량적으로 평가하였다. 실험 데이터 분석 결과, 사용하는 차원의 수가 증가할수록 결함 진단의 정확도가 향상되는 것으로 나타났다. 차원이 10 이상에 다다르면 거의 모든 고장상태가 정확하게 분류되었으며, 이는 고장진단 정확도를 저하시키지 않으면서도 진동 신호의 차원수를 크게 줄일 수 있음을 보여준다. 변수 중요도 분석에서도 차원 축소 주성분이 기존 통계적 특성보다 더 높은 기여도를 보였으며, 차원 축소된 진동 스펙트럼이 고장진단에 효과적으로 사용될 수 있음을 확인하였다.

교량 모니터링을 위한 스마트 무선 계측 시스템 개발 (Development of Smart Wireless Measurement System for Monitoring of Bridges)

  • 허광희;이우상;이진옥;전준용;손동진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.170-178
    • /
    • 2011
  • 본 논문에서는 MEMS 센서와 블루투스 무선 통신 모듈을 이용하여 교량 모니터링을 위한 무선 계측 시스템 개발에 대한 연구를 수행하였다. 이를 위하여 MEMS 센서의 가속도 측정 범위 및 주파수 응답 범위 성능을 검증하기 위한 실험을 수행하여 교량 계측에 적합성 여부를 판단하였다. 실험 결과, 고성능의 압전형 가속도 센서에 비하여 동적 범위와 측정 주파수 범위의 성능은 낮으나 30Hz 미만의 저주파수 대역 측정에는 무리가 없을 것으로 판단한다. 그리고 최대 통신 거리 측정 결과, 280m정도의 성능을 가지고 있음을 확인하였다. 마지막으로 개발된 무선 가속도 센서 시스템을 공용중인 교량에 설치한 후, 교통하중에 의한 진동데이터를 획득하여 교량의 동특성을 실시간 분석하였다. 분석결과는 대상교량의 FE 해석결과와 비교를 통하여 무선 가속도 센서 시스템의 성능을 평가하였다. 실험 결과, MEMS 센서와 블루투스 무선 통신 모듈을 이용하여 개발한 무선 가속도 센서는 교량과 같은 저주파수 진동특성을 갖는 건설구조물의 계측에 효과적으로 사용할 수 잇을 것으로 판단된다.

자유 진동 실험을 통한 VRS-RTK 기법을 이용한 골조 구조물의 모니터링 적용성 검토 (Verification on the Application of Monitoring for Frame Structures Using the VRS-RTK Method through the Free Vibration Test)

  • 최세운;박효선;김법렬;이홍민;김유석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.174-182
    • /
    • 2014
  • 건물의 풍진동을 모니터링 하기 위해, 두 개 (이동국과 기준국)의 global positioning system (GPS)에 기반한 종래의 real-time kinematic (RTK) 기법이 널리 적용되고 있다. 그러나 이는 기준국을 위한 공간을 확보하거나 유지 관리하는데 어려움을 겪을 수 있다. 한편, 최근에 하나의 이동국 만을 이용하여 구조물의 움직임을 계측할 수 있는 새로운 virtual reference station (VRS)-RTK 기법이 개발되었으며, 측량 분야에서 널리 사용되고 있다. 본 연구에서는 골조 구조물의 횡방향 구조 응답을 모니터링하기 위한 VRS-RTK 기법의 적용성을 평가하기 위해 단층 골조 모형 (1차 고유진동수 : 1 Hz)과 3층 골조 모형 (1차 고유진동수 : 0.85 Hz)의 자유진동 실험을 수행하였다. GPS에 의해 계측된 변위 및 가속도 응답의 신뢰성을 평가하기 위해, 레이져 변위계와 가속도계가 설치되었으며, 이들로부터 얻은 계측값을 GPS의 계측값과 비교하였다. 또한, 건물의 지속적인 모니터링을 위한 적절한 계측 샘플링 수를 파악하기 위해, 변위 응답에서의 오차가 각기 다른 GPS 샘플링 수 (5, 10, 20 Hz)에서 평가되었다. 실험 결과, GPS으로부터 얻은 변위 및 가속도 응답은 레이져 변위계와 가속계로부터 얻은 응답과 좋은 유사 관계를 가지는 것을 확인하였다. 그리고, GPS 샘플링 수가 증가할수록 변위 오차는 감소하였으며, 3층 실험체에 대해서는 20 Hz의 GPS 샘플링 수로 구조물의 전 모드 성분 (1, 2, 3차 모드)을 검출할 수 있었다.

새로운 해양 방사선 자동 감시 시스템의 개발 (Development of New Ocean Radiation Automatic Monitoring System)

  • 김재형;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.743-746
    • /
    • 2019
  • 본 논문에서는 새로운 해양 방사선 자동 감시 시스템을 제안한다. 제안하는 시스템은 다음과 같은 특징들을 가진다. 첫 번째로 NaI + PVT 혼합형 검출기를 사용함으로 반응속도가 빠르고 정밀분석이 가능하다. 두 번째로 섬광체형 센서에 온도보상 알고리즘을 적용함으로서 추가적인 냉각장치가 필요 없으며 시시각각 변화하는 해양환경에 안정적인 운영이 가능하다. 세 번째로 냉각장치가 필요 없으므로 전력소비량이 적어 태양열을 활용하여 전력의 안정적인 공급이 가능하므로 해양환경 관측부이에 설치 가능하다. 네 번째로 GPS 및 무선통신을 사용하여 측정지역에 대한 정확한 위치정보와 실시간 데이터 전송기능으로 주변국 등의 원전사고 등 발생 시 즉각적인 경보대응이 가능하다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선 측정범위는 세계 최고 수준인 $5{\mu}Sv/h{\sim}15mSv/h$의 범위에서 측정이 되었고, 정확도는 ${\pm}8.1%$의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. 내환경등급(방수)은 IP67을 달성하였고, $-20{\sim}50^{\circ}C$ 동작온도에서 5% 이내로 변동률이 측정되어서 안정성이 확인되었다. 진동시험 후 측정값 변화율이 10% 이내로 측정되어서, 파도에 의한 해양환경에서 진동으로 인한 측정값의 변화가 없을 것으로 확인되었다.

Seismic and vibration tests for assessing the effectiveness of GFRP for retrofitting masonry structures

  • Michelis, Paul;Papadimitriou, Costas;Karaiskos, Grigoris K.;Papadioti, Dimitra-Christina;Fuggini, Clemente
    • Smart Structures and Systems
    • /
    • 제9권3호
    • /
    • pp.207-230
    • /
    • 2012
  • Full-scale shake table seismic experiments and low-amplitude vibration tests on a masonry building are carried out to assess its seismic performance as well as study the effectiveness of a new multifunctional textile material for retrofitting masonry structures against earthquakes. The un-reinforced and the retrofitted with glass fiber reinforced polymer (GFRP) strips masonry building was subjected to a series of earthquake excitations of increasing magnitude in order to progressively induce various small, moderate and severe levels of damage to the masonry walls. The performance of the original and retrofitted building states is evaluated. Changes in the dynamic characteristics (lowest four modal frequencies and damping ratios) of the building are used to assess and quantify the damage states of the masonry walls. For this, the dynamic modal characteristics of the structure states after each earthquake event were estimated by performing low-amplitude impulse hammer and sine-sweep forced vibration tests. Comparisons between the modal results calculated using traditional accelerometers and those using Fiber Bragg Grating (FBG) sensors embedded in the reinforcing textile were carried on to investigate the reliability and accuracy of FBG sensors in tracking the dynamic behaviour of the building. The retrofitting actions restored the stiffness characteristics of the reinforced masonry structure to the levels of the original undamaged un-reinforced structure. The results show that despite a similar dynamic behavior identified, corresponding to reduction of the modal frequencies, the un-reinforced masonry building was severely damaged, while the reinforced masonry building was able to withstand, without visual damage, the induced strong seismic excitations. The applied GFRP reinforcement architecture for one storey buildings was experimentally proven reliable for the most severe earthquake accelerations. It was easily placed in a short time and it is a cost effective solution (covering only 20% of the external wall surfaces) when compared to the cost for full wall coverage by GFRPs.