• 제목/요약/키워드: Vibration Isolation Technology

검색결과 98건 처리시간 0.027초

블레이드 기어를 적용한 2축 짐발 구동 안테나의 미소진동 절연성능 (Micro-vibration Isolation Performance of X-band Antenna Using Blade Gear)

  • 전수현;권성철;김태홍;김용훈;오현웅
    • 한국소음진동공학회논문집
    • /
    • 제25권5호
    • /
    • pp.313-320
    • /
    • 2015
  • A 2-axis gimbal-type X-band antenna has been widely used to effectively transmit the high resolution image data from the observation satellite to the desired ground station. However, a discontinuous stepper motor activation for rotating the pointing mechanism in azimuth and elevation directions induces undesirable micro-vibration disturbances which can result in the image quality degradation of a high-resolution observation satellite. To enhance the image quality of the observation satellite, attenuating the micro-vibration induced by an activation of the stepper motor for rotational movements of the antenna is important task. In this study, we proposed a low-rotational-stiffness blade gear applied to the output shaft of the stepper motor to obtain the micro-vibration isolation performance. The design of the blade gear was performed through the structure analysis such that this gear is satisfied with the margin of safety rule under the derived torque budget. In addition, the micro-vibration isolation performance of the blade gear was verified through the micro-vibration measurement test using the dedicated micro-vibration measurement device proposed in this study.

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

A novel prismatic-shaped isolation platform with tunable negative stiffness and enhanced quasi-zero stiffness effect

  • Jing Bian;Xuhong Zhou;Ke Ke;Michael C.H. Yam;Yuhang Wang;Zi Gu;Miaojun Sun
    • Smart Structures and Systems
    • /
    • 제31권3호
    • /
    • pp.213-227
    • /
    • 2023
  • A passive prismatic-shaped isolation platform (PIP) is proposed to realize enhanced quasi-zero stiffness (QZS) effect. The design concept uses a horizontal spring to produce a tunable negative stiffness and installs oblique springs inside the cells of the prismatic structure to provide a tunable positive stiffness. Therefore, the QZS effect can be achieved by combining the negative stiffness and the positive stiffness. To this aim, firstly, the mathematical modeling and the static analysis are conducted to demonstrate this idea and provide the design basis. Further, with the parametric study and the optimal design of the PIP, the enhanced QZS effect is achieved with widened QZS range and stable property. Moreover, the dynamic analysis is conducted to investigate the vibration isolation performance of the proposed PIP. The analysis results show that the widened QZS property can be achieved with the optimal designed structural parameters, and the proposed PIP has an excellent vibration isolation performance in the ultra-low frequency due to the enlarged QZS range. Compared with the traditional QZS isolator, the PIP shows better performance with a broader isolation frequency range and stable property under the large excitation amplitude.

디젤엔진의 근접 음향 차폐장치 설계 및 성능평가 (Design of Close-Fitting Acoustic Enclosure of Diesel Engine)

  • 류정수;정우진;전재진
    • 한국군사과학기술학회지
    • /
    • 제2권1호
    • /
    • pp.82-89
    • /
    • 1999
  • In this article, the performances of acoustic enclosure with double resilient mount system which was designed by ADD to reduce the radiated noise by main noise source of ships, was tested and evaluated. From test results, it was verified that the acoustic performances of acoustic enclosure satisfied the requirements; vibration isolation level at 1st stage mount system of 15 ㏈ and airborne noise reduction level of 20 ㏈ in broad band.

  • PDF

지반진동절연을 위한 공압제진대의 전달률 설계기법 (An Efficient Transmissibility-design Technique for Pneumatic Vibration Isolator)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.411-423
    • /
    • 2008
  • Pneumatic vibration isolator has a wide application for ground-vibration isolation of vibration-sensitive equipments. Recent advances In precision machine tools and instruments such as nano-technology or medical devices require a better isolation performance, which can be efficiently done by precise modeling- and design- of the isolation system. This paper will discuss an efficient transmissibility design method for pneumatic vibration isolator by employing the complex stiffness model of dual-chamber pneumatic spring developed in our previous research. Three design parameters of volume ratio between the two pneumatic chambers, the geometry of capillary tube connecting the two pneumatic chambers and finally the stiffness of diaphragm necessarily employed for prevention of air leakage were found to be important factors in transmissibility design. Based on design technique that maximizes damping of dual-chamber pneumatic spring, trade-off among the resonance frequency of transmissibility, peak transmissibility and transmissibility in high frequency range was found, which was not ever stated in previous researches. Furthermore this paper will discuss about negative role of diaphragm in transmissibility design. Then the design method proposed in this paper will be illustrated through experiment at measurements.

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

열차 진동 저감을 위한 마찰쐐기형 방진장치의 거동 시험 (A Behavior Test on a Frictional-Wedge-Type Vibration Isolation Device for Vibration Reduction of a Railway Track)

  • Lee, Chanyoung;Choi, Sanghyun;Lee, Yooin;Kwon, Segon;Koh, Yongsung;Ji, Yongsoo
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.45-54
    • /
    • 2015
  • 도심지에 건설되는 철도역사, 선로구조물 등 철도시설물의 경우 소음 및 진동 저감 설계의 중요성이 더욱 커지고 있다. 특히 선하역사는 구조물 위에 선로가 놓이게 되므로 철도 진동과 이로 인한 2차 소음을 효과적으로 차단할 수 있는 진동 제어 대책이 더욱 필요한 상황이다. 수직형 방진장치는 열차 운행으로 인한 진동이 직접적으로 전달되는 선하역사 등 철도시설물의 진동 저감에 효과적으로 적용될 수 있으나, 수평형 장치에 비하여 개발이 미진한 상황이다. 이 논문에서는 열차에 의한 진동을 효과적으로 저감하기 위해 개발 중인 마찰쐐기형 방진장치를 소개하고, 동적성능 검증을 위한 시험 결과를 제시하였다. 개발된 방진장치의 성능 검증을 위하여 시제품을 적용한 콘크리트구조물에 대한 강제 가진시험을 수행하였으며, 시험결과를 통해 방진장치의 방진성능 및 동특성을 검증하고 방진장치 개선사항을 검토하였다.

외부챔버와 유연한 튜브로 연결된 LCD 패널 검사기 방진용 공기 스프링의 열 및 동적 연성거동에 대한 연구: PART I, 이론적 모델링 (Study on the Thermal and Dynamic Behaviors of Air Spring for vibration isolation of LCD panel inspecting machine connected with an External Chamber through a flexible tube: PART I, Theoretical Modeling)

  • 석종원;이주홍;김필기
    • 반도체디스플레이기술학회지
    • /
    • 제10권1호
    • /
    • pp.33-41
    • /
    • 2011
  • Due to the recent quantum leaps forward in bio-, nano-, and information-technologies (BT, NT and IT), the precisionization and miniaturization of mechanical and electrical components are in high demand. In particular, the ITrelated equipments that take a great part in our domestic industry are in the area requiring high precision technologies. As a consequence, the researches on the development vibration isolation systems that diminish external disturbance or internal vibration are highly required. Among the components comprising the vibration isolation system, air spring has become on a focal point for the researchers due to its merits. This air spring is able to support heavy loads, keep a low natural frequency despite of having a lower value of stiffness, and control the performance of vibration isolation. However, sometimes the sole use of air spring is in demand due to some economic reasons. Under this circumstance, the damping effect of sole air spring may not enough to reduce sufficient amount of vibration. In this study, the air spring mount system connecting with an external chamber is proposed to increase or control the damping effect. To investigate its damping mechanism, the thermal and dynamic behaviors of the system is examined through a theoretical modeling approach in this part of research. In this approach, thermomechanical and Helmholtz resonator type models are to be employed for the air spring/external chambers and connecting tube system, respectively. The frequency response functions (FRFs) derived from the modeling effort are evaluated with physical parametric values and the effects of connecting tube length on these FRFs are identified through computer simulations.

Dynamic assessment of the seismic isolation influence for various aircraft impact loads on the CPR1000 containment

  • Mei, Runyu;Li, Jianbo;Lin, Gao;Zhu, Xiuyun
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1387-1401
    • /
    • 2018
  • An aircraft impact (AI) on a nuclear power plant (NPP) is considered to be a beyond-design-basis event that draws considerable attention in the nuclear field. As some NPPs have already adopted the seismic isolation technology, and there are relevant standards to guide the application of this technology in future NPPs, a new challenge is that nuclear power engineers have to determine a reasonable method for performing AI analysis of base-isolated NPPs. Hence, dynamic influences of the seismic isolation on the vibration and structural damage characteristics of the base-isolated CPR1000 containment are studied under various aircraft loads. Unlike the seismic case, the impact energy of AI is directly impacting on the superstructure. Under the coupled influence of the seismic isolation and the various AI load, the flexible isolation layer weakens the constraint function of the foundation on the superstructure, the results show that the seismic isolation bearings will produce a large horizontal deformation if the AI load is large enough, the acceleration response at the base-mat will also be significantly affected by the different horizontal stiffness of the isolation bearing. These concerns require consideration during the design of the seismic isolation system.

제진대(Isolation Pad)의 진동허용규제치에 기준한 동특성(動特性) 규명에 관한 연구 (A Study on the Verification of Dynamic Properities on the basis of Vibration Criteria of Isolation Pad)

  • 백재호;이홍기;서항석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.869-874
    • /
    • 2001
  • In order that precision equipment using high precision industrial operate normally. vibration criteria of expected area that equipment be set up is micrometer level. that method is a trust design for apply to in field, when there attend to quantifiable method. Hence, semi -empirical method that using on the basis of experimental data about undefined information (properities of vibration source, dynamic properities of structure, etc.,) for prediction of vibration response make the use of dynamic structure design of semiconductor & TFT-LCD in the inside and outside country. Like this, for doing an optimal design of dynamic about structure, it is best important to get trust data that apply to semi-empirical method that is method of prediction vibration level. In this paper, on the basis of experimental data which was offered by a manufacturing company Of precisin equipment that plan to set up in semiconductor factory, we predicted vibration response on expected area that equipment be set up.

  • PDF