• Title/Summary/Keyword: Vibration Correlation Technique

Search Result 80, Processing Time 0.033 seconds

A Trajectory Identification Technique for Two Rotating Sound Sources with Different Frequencies (서로 다른 주파수를 갖는 두 개의 회전음원의 위치추적에 대한 연구)

  • Lee, Jong-Hyun;Lee, Ja-Hyung;Rhee, Wook;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.710-718
    • /
    • 2009
  • The time difference of arrival(TDOA) algorithm is being used widely for identifying the location of a source emanating either electrical or acoustic signal. It's application areas will not be limited to identifying the source at a fixed location, for example the origin of an earthquake, but will also include the trajectory monitoring for a moving source equipped with a GPS sensor. Most of the TDOA algorithm uses time correlation technique to find the time delay between received signals, and therefore difficult to be used for identifying the location of multiple sources. In this paper a TDOA algorithm based on cross-spectrum is developed to find the trajectory of two sound sources with different frequencies. Although its application is limited to for the sources on a disk plane, it can be applied for identifying the locations of more than two sources simultaneously.

The rank determination for the source identification utilizing partial coherence function technique (부분 기여도 함수를 이용한 소음/진동원 검출에 있어서의 우선순위 결정에 관한 연구)

  • 박정석;김광준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.3-8
    • /
    • 1990
  • 소음/진동 문제를 해결하는 데 있어서 우선은 소음/진동원들의 위치를 알아 내고 그들 중에 비중이 가장 큰 소음/진동원을 파악하는 것이 중요하다. 다 입력/단일출력 모형을 이용한 소음/진동원 규명에 대한 방법에는 주파수 응 답함수를 이용하는 방법(frequency response function approach)과 부분 기여 도 함수(partial coherence function)를 이용하는 방법 등이 있는데, 입력들 사이의 상호상관(correlation)이 없는 경우에는 전자의 방법을 사용하여 출력 에 가장 큰 비중을 차지하는 소음/진동원을 알아낼 수 있으나 상호상관이 존 재하는 경우에는 후자의 방법을 사용하게 된다. 그러나 후자의 방법을 적용 함에 있어서도 기본적으로 소음/진동원들의 위치를 알아야 하는 것 이외에 그들 사이의 원인.효과관계(causaling), 또는 우선순위(rank)를 우선적으로 아 는 것이 중요한데 이는 입력들 사이의 우선순위를 어떻게 두느냐에 따라 해 석 결과가 다르게 나타나기 때문이다 [1,2,3]. 본 연구에서는 부분 기여도 함 수를 이용하여 소음/진동원을 규명할 때 그들 사이의 우선순위를 결정하는 방법을 제시하고 2입력/1출력 모형에 대해 적용하여 보았다.

  • PDF

Reduced Density Matrix Theory for Vibrational Absorption Line Shape in Energy Transfer Systems: Non-Condon Effects in Water

  • Yang, Mi-No
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.439-443
    • /
    • 2011
  • Using the projection operator technique, a reduced density matrix theory for linear absorption spectrum of energy transfer systems is developed for the theoretical absorption line shape of the systems with non-Condon transitions. As an application, we considered a model system of OH vibrations of water. In the present model calculation, the OH vibration modes are coupled to each other via intra-molecular coupling mechanism while their intermolecular couplings are turned off. The time-correlation functions appearing in the formulation are calculated from a mixed quantum/classical mechanics method. The present theory is successful in reproducing the exact absorption line shape. Also the present theory was improved from an existing approximate theory, time-averaged approximation approach.

Prediction Of Vibrating Panel's Radiating Noise By Transfer Path Analysis (전달경로해석법에 의한 진동하는 판넬의 방사 소음 예측)

  • Oh, Jae-Eung;Lee, Sun-Hun;Jeong, Un-Chang;Kim, Jin-Su;Lee, You-Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.292-293
    • /
    • 2014
  • Transfer Path Analysis is technique predicting transmitted energy through each path. Using the Transfer Path Analysis, structure-borne noise and air-borne noise can be predicted from the system. In this study, however, the Transfer Path Analysis to target only the structure-borne noise due to the noise radiated from the vibrating panel was performed. Predicted noise by the Transfer Path Analysis and measured noise by the experiment were a high correlation. We confirmed the validity of the Transfer Path Analysis through the analysis of these results, showed how to apply the Transfer Path Analysis.

  • PDF

Lifetime improvement of 4P Magnetic Contactor (4P 전자접촉기의 수명 향상)

  • Lee, Kyung-Ku;Ryu, Jong-Sang;Kim, Gyeon-Mook;Park, Ji-Hong;Jo, Hyun-Kil;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.42-44
    • /
    • 2001
  • This paper proposes impact vibration theory of magnetic contactor moving mechanism and correlation test the bouncing time with the spring load. Mechanical and electrical lifetime is under the influence of impact vibration of magnetic contactor moving mechanism. In shortage of technique, we have experienced many difficulties in magnetic contactor development. By this research, we analyzed total moving mechanism and applied results to optimum 4p magnetic contactor development.

  • PDF

Measurement of Material Deformation Using Laser Speckle (레이저 스페클을 이용한 재료 변형 측정)

  • 전문창;강기주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.688-694
    • /
    • 2002
  • As a tool for strain measurement to work with screw driven or hydraulic material test systems, in which mechanical vibration is inherent, SSDG(Speckle Strain/Displacement Gage), ESP(Electronic Speckle Photography) and its 3-dimension version SDSP are investigated for the theory and practical appliance. Through tension test of steel strips, their validity and shortcomings are examined. As the results, it has been shown that, although SSDG and ESP provide direct measurement of in-plane strain in one direction, they are so sensitive to the out-plane displacement. On the other hand, SDSP which is aided with DIC (Digital Image Correlation) technique to trace the movement of the speckles provides not only in-plane 2-dimensional displacement field, but also out-of-plane displacement simultaneously. However, because the DIC is time-consuming, not automated yet and it needs post-processing to evaluate strain from the displacement field, SDSP appears to be not adequate as a real time sensor.

  • PDF

Development of a High Power SONAR System Measuring Velocity by Using Two Gated Sinusoidal Signals (두 개의 정현 신호를 이용한 속도 측정용 고전력 쏘나 시스템 개발)

  • 장순석;안흥구;이제형
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.1036-1041
    • /
    • 1999
  • This paper aims for the development of the high power sonar system for measuring the velocity of a moving object. The high power sonar system transmits two gated 190 kHz sinusoidal signals with 1.6 [ms] time interval to the moving object. Then the sonar system detects and calculates the changed time delay of the reflected ultrasonic signals in order to derive the velocity of the moving object. The transmission part uses a high power amplifier so that 250 W gated sinusoidal signals can be transmitted to the transmitter. 1M RAM is utilized for transmitting and storing of the ultrasonic signals. The time delay is calculted by the cross-correlation technique between the transmitted signals and the received signals. The measured value from the high power sonar system is compared with directly measured values by photo diodes. The result confirms the adjacency to 0.3% error.

  • PDF

Output only structural modal identification using matrix pencil method

  • Nagarajaiah, Satish;Chen, Bilei
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.395-406
    • /
    • 2016
  • Modal parameter identification has received much attention recently for their usefulness in earthquake engineering, damage detection and structural health monitoring. The identification method based on Matrix Pencil technique is adopted in this paper to identify structural modal parameters, such as natural frequencies, damping ratios and modal shapes using impulse vibration responses. This method can also be applied to dynamic responses induced by stationary and white-noise inputs since the auto- and cross-correlation function of the two outputs has the same form as the impulse response dynamic functions. Matrix Pencil method is very robust to noise contained in the measurement data. It has a lower variance of estimates of the parameters of interest than the Polynomial Method, and is also computationally more efficient. The numerical simulation results show that this technique can identify modal parameters accurately even if the noise level is high.

In-situ Measurement of Plastic Zone Developed During Ductile Fracture Process (연성 금속의 파괴과정에서 발생하는 소성영역의 현장 측정)

  • Back Jung-Hyun;Kim Do-Hyung;Kang Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.637-642
    • /
    • 2006
  • A plastic zone size is regarded as a measure of material resistance, and also it determines the fracture behavior. The importance of estimating or measuring the plastic zone size cannot be too emphasized. In this article, SDSP(Stereo Digital Speckle Photography) is examined as a new techniques to measure the plastic zone developed in a ductile metal. This technique is simple, vibration free and non-contact, and measures simultaneously in-plane displacements as well as out-of plane displacements like the side necking. Experimental results for a CT specimen are presented to demonstrate the accuracy in comparison with those obtained by recrystallization technique and finite element analysis.

A noble RBC aggregometer with vibration-induced disaggregation mechanism

  • Shin S.;Jang J.H.;Park M.S.;Ku Y.H.;Suh J.S.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2005
  • The aggregation of red blood cells (RBCs) is a major determinant of blood flow resistance passing through various veins. Available techniques for measuring RBC aggregation often require pretreating and washing after each measurement, which is not optimal for day-to-day clinical use. A laser reflection technique has been combined with a vibration-aided disaggregation mechanism, which shows significant advances in aggregometer design, operation and data analysis. The essential features of this design are in its simplicity and a disposable element that is in contact with the blood sample. Using extremely small quantities of blood, the RBCs subjected to vibrations can be quickly and completely disaggregated. This is followed by measuring the backscattered light intensity. The measurements with the present sensor were compared with those of a commercial aggregometer and a strong correlation was found between them. The newly-developed optical aggregometer can measure the RBC aggregability difference between young and old cell suspension with ease and accuracy.