• 제목/요약/키워드: Vibration Control

검색결과 4,097건 처리시간 0.036초

Vibration Suppression Control for a Twin-Drive Geared Mechanical System with Backlash: Effects of Model-Based Control

  • Itoh, Masahiko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1392-1397
    • /
    • 2003
  • This paper deals with a control technique of eliminating the transient vibration of a twin-drive geared mechanical system. This technique is based on a model-based control in order to establish the damping effect at the driven machine part. The control model is composed of reduced-order electrical and mechanical parts. This control model estimates a load speed converted to the motor shaft. The difference between the estimated load speed and the motor speed is calculated dynamically and it is added to the velocity command to suppress the transient vibration generated at the load. This control technique is applied to a twin-drive geared system with backlash. In the previous work, the performance of this control method is examined by simulations. In this paper, the effectiveness of this control technique is verified by experiments. The settling time of the residual vibration generated at the loading inertia can be shortened down to about 1/2 of the uncompensated vibration level.

  • PDF

종파 분리 방법을 이용한 파동 관점의 능동 진동 제어 (Study on active vibration control based on wave viewpoint using the longitudinal wave separation method)

  • 정병보;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.928-933
    • /
    • 2007
  • In this research, we investigated active vibration control based on wave-viewpoint using the longitudinal wave separation method. The control strategy is the one of active vibration control technique for generating vibration reduced zone and uses wave information including the directivity as the cost function. In order to get the wave information from the measured values, we proposed and examined the time-domain longitudinal wave separation method proper to real time application like active vibration control. Using the proposed method, we examine the performance and feasibility of active vibration control based wave view-point through the simulation. The related experimental verification and application is going to be expected in a near future.

  • PDF

트랜스미션 컨트롤 케이블의 진동 해석을 위한 모델링 (Modeling of a Transmission Control Cable for Vibration Analysis)

  • 이병수;최해운
    • 한국소음진동공학회논문집
    • /
    • 제18권5호
    • /
    • pp.550-557
    • /
    • 2008
  • A transmission control cable connects the transmission control arm and the control lever mechanically and transfers control effort exerted by a driver to the transmission. It also transfers vibration generated by the engine to the passenger room through mechanical connection. To understand vibration and noise transfer mechanism and to further find a way to suppress the transmission of vibration effectively, a dependable dynamic vibration model is a necessity. A vibration model for a transmission control cable is developed and a simulation study has been conducted to obtain mode frequencies and a transmittability. The resonance frequencies obtained by an harmonic analysis is compared with the noise level measurement data. The measurement agrees with the simulation result thus ensures the reliability of the model.

주파수가변 압전 트랜스듀서를 이용한 능동제진법 (Active Vibration Control Method Using Frequency Controllable Piezoelectric Transducer)

  • 김정순;김무준;하강렬;강성학
    • The Journal of the Acoustical Society of Korea
    • /
    • 제26권1E호
    • /
    • pp.27-32
    • /
    • 2007
  • Hydraulic actuator and electro-magnetic liner actuator have been used as typical active vibration control methods. However these methods have many kinds of disadvantages such as causing space limit, difficult maintenance, complicate structures, etc. The purpose of this paper was to study on the possibility of active vibration control using piezoelectric transducer. Piezoelectric transducer generated a vibration and GIC (General Impedance Converter) amplifier was adopted to give adjustable vibration signal to transducer and high amplitude of vibration. Resonance frequency of piezoelectric transducer was controlled by GIC amplifier and higher amplitude of vibration was achieved. Finally active vibration control using piezoelectric transducer was performed.

중대형 왕복동 기관의 진동제어를 위한 능동형 역기진기 제어 알고리즘 개발 (Development of Active Vibration Control Algorithms for the Compensator of Medium-to-large Size Reciprocating Engines)

  • 김대현;고병준;홍석윤;이영제
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.348-356
    • /
    • 2003
  • Active vibration control algorithms for the compensator and proto-type testing system have been developed for the suppression of vibrations from the reciprocating engines. At first, the developed algorithm determines optimal control vibration phases by detecting vibration responses of the engine without and with compensator, and then performs the continuous optimal control functions by tracking the change of the vibration frequency and phase. This algorithm is comparatively simple. robust for the external excitations and needless of supplementary operation since the control process is serially carried out. To validate the performance of compensator and algorithm, testing system including excitation device are constructed and tested, and the reductions of vibration levels are observed over than 80 % of the uncontrolled levels at various frequency ranges.

고속 엘리베이터의 전후 진동제어를 위한 동적 모델링 및 능동 제어기 설계 (Dynamic Modeling and Controller Design for Active Control of High-speed Elevator Front-back Vibrations)

  • 백광현;김기영;곽문규
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.74-80
    • /
    • 2011
  • Front-back vibrations of high-speed elevator need to be suppressed as in the case of lateral vibrations. The dynamic model for the front-back vibrations is different from the lateral vibration model since the supporting structure varies. In this study, a dynamic model was derived using the energy method. Based on the free vibration analysis, it was observed that the fundamental frequency for the front-back vibration is slightly lower than the fundamental frequency of the lateral vibration, which means that the active vibration control should be carried out in both directions. The PPF control algorithm was applied to the numerical model under measured rail irregularities. The numerical results show that the active vibration control of elevator front-back vibration is also possible.

대형 구조물의 진동제어를 위한 반능동형 댐퍼의 설계 (Design of Semi-Active Tendon for Vibration Control of Large Structures)

  • 김상범;윤정방;구자인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.282-286
    • /
    • 2000
  • In this paper, magneto-rheological(MR) damper is studied for vibration control of large infra structures under earthquake. Generally, active control devices need a large control force and a high power supply system to reduce the vibration effectively. Large and miss tuned control force may induce the dangerous situation such that the generated large control force acts to amplify the structural vibration. Recently, to overcome the weaknesses of the active control, the semi-active control method is suggested by many researchers. Semi-active control uses the passive control device of which the characteristics can be modified. Control force of the semi-active device is not generated from the actuator with power supply. It is generated as a dynamic reaction force of the device same as in the passive control case, so the control system is inherently stable and robust. Unlike the case of passive control, control force of semi-active control is adjusted depending on the measured response of the structure, so the vibration can be reduced more effectively against various unknown environmental loads. Magneto-rheological(MR) damper is one of the semi-active devices. Dynamic characteristics of the MR material can be changed by applying the magnetic fields. So the control of MR damper needs only small power. Response time of MR to the input voltage is very short, so the high performance control is possible. MR damper has a high force capacity so it is adequate to the vibration control of large infra structure. Because MR damper has a nonlinear property, normal control method used in active control may not be effective. Clipped optimal control, modified bang-bang control etc. have been suggested to MR damper by many researchers. In this study, sliding mode fuzzy control(SMFC) is applied to MR damper. Genetic algorithm is used for the controller tuning. To verify the applicability of MR damper and suggested algorithm, numerical simulation on the aseismic control is carried out. Simulation model is three-story building structure, which was used in the paper of Dyke, et al. The control performance is compared with clipped optimal control. The present results indicate that the SMFC algorithm can reduce the earthquake-induced vibration very effectively.

  • PDF

공기스프링 방진대의 능동제어 (Active Control of Air-Spring Vibration Isolator)

  • 송진호;김규용;박영필
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1605-1617
    • /
    • 1994
  • Air-spring is widely used in vibration isolation to reduce the table vibration. When a disturbance is applied to a table, however, it starts virbrating with a low frequency, but has a large displacement due to the reacting force of air-spring. In this study, to solve the table vibration problem, an active vibration control device based on state feedback control using air-spring and proportional control valves was designed. This device can suppress the displacement of the isolation table within allowable range, even any kind of disturbances are applied to the table. Firstly, theoretical analysis of an air-spring isolator was done. Secondly, characteristics of the isolator was investigated via computer simulation and experiment. Finally, active control of air-spring isolator was tested using optimal(LQG) and fuzzy control algorithms was performed to show the effectiveness of the control schems.

끝단이 탄성 지지된 강체판의 최적진동제어 (Optimal Vibration Control of Rigid Plate Elastically Supported at the Edges)

  • 이성기;윤신일;한상보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.828-833
    • /
    • 2003
  • Rigid plate elastically supported at the edges is modeled and the performance of the optimal vibration control under sinusoidal excitation is tested. The controller based on the linear quadratic regulator with output feedback is designed to control the multi-degree of freedom vibration. Relative weighting parameters are considered as design constraints to determine the limitation of maximum control force and state parameters. Control force calculated by proportional output feedback of the displacement and velocity is used to suppress the vibration induced by the sinusoidal external force. The active vibration control of vibrating plate by the LQR controller is examined through the numerical simulations that show the effectiveness of optimal control scheme on the three degrees of freedom structure.

  • PDF

무인항공기 임무장비용 압전 마운트 시스템의 진동 제어 성능 평가 (Evaluation of Vibration Control Performance of Camera Mount System for UAV)

  • 오종석;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.407-412
    • /
    • 2009
  • In the present work, vibration control performance of active camera mount system for unmanned aero vehicle (UAV) is evaluated. An active mount featuring inertia type of piezostack actuator is designed and manufactured. Then, vibration control performances are experimentally evaluated. A camera mount system with four active mounts is constructed and mechanical model is established. The governing equation for the camera mount system is obtained and control model is constructed in state space model. Sliding mode controller which has inherent robustness to external disturbance is designed and implemented to the system. Vibration control performances are evaluated at each mount and center of gravity point. Effective vibration performances are obtained and presented in time and frequency domains.

  • PDF