• Title/Summary/Keyword: Vibration Characteristics Test

Search Result 1,123, Processing Time 0.031 seconds

A Study on the Characteristics of the Excited Vibration Signals in a Thermosonic Test (초음파가진 열화장시험 시 가전된 진동 신호 특성 연구)

  • Kang, Bu-Byoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.118-126
    • /
    • 2011
  • The characteristics of the responses obtained in thermosonic tests are investigated in this study to improve the performance of a thermosonic test system. Thermosonic tests are conducted with an acoustic horn with high power capability to investigate the characteristics of the vibration produced in turbine blades with complex geometry. The influences of the excitation signal that is input to the horn and the coupling methods between a clamp and the acoustic horn on the characteristics of the vibration excited in a component are presented. As a result, an excitation method with a fast narrow band chirp test (sweep test) and a stud coupling is proposed as an excitation method for thermosonic testing. This method can be applied to different types of turbine blades and also to other components.

An Experimental Study on the Vibraton Characteristics of a Continuous Circular Cylindrical Shell with the Multi-simple Support (다점 단순지지된 연속원통셸의 진동특성에 대한 실험적 고찰)

  • Lee, Y.S.;Han, C.H.;Kim, K.T.;Kim, H.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.568-574
    • /
    • 2000
  • This paper presents the vibration characteristics of a continuous circular cylindrical shell multi-simply supported at arbitrary axial positions for searching design parameters. In this modal test the impulse test method is applied to the excitation of experimental model. Natural frequencies are obtained from the peak points of frequency response function(FRF) through frequency analyzer and vibration behaviors are investigated. FE analysis is performed with ANSYS 5.5 to improve the reliability of experimental results. Their results are compared with experimental results. The effect of dynamic characteristics is analyzed for the number of support point on the shell.

  • PDF

Vibration Analysis of Rotating System in a Turbine and Generator Set: Comparison of Shrunk-fit Disc Rotor and Welded Drum Rotor (터빈발전기의 축계 진동 해석: 열박음형과 용접형 로터의 진동 특성 비교)

  • Ha, Hyun-Cheon;Park, Chul-Hyun;Choi, Seong-Pil;Kim, Kay-Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.599-604
    • /
    • 2000
  • Excessive vibration magnitude results in serious damage and economic losses in the turbine and generator system. Therefore, it is of importance to evaluate the accurate dynamic characteristics of the system in advance. In this paper, rotordynamic characteristics of both the shrunk-fit disc and welded drum rotors have been investigated to ensure an excellent running behavior of the system in which low-pressure(LP) turbines of a nuclear power plant were retrofitted to improve thermal efficiency and reliability. Analysis shows that the welded drum rotor has good torsional characteristics rather than the shrunk-fit disc rotor. In addition, verification testing of field test was performed to confirm the retrofit. Test results are good agreement with analysis ones.

  • PDF

A Study on Flow and Vibration Analysis, and Performance Test for Automotive Fuel Pump (자동차 연료펌프의 유동 및 진동 해석과 성능시험에 관한 연구)

  • Son, Jae-Hwan;Bae, Jung-Sub;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1496-1502
    • /
    • 2012
  • The fuel pump mounted on the engine in the vehicle is consist of the outer and inter rotors, and which inhales fuel from the inlet port and supplies it to the outlet port. In this study, it is carried out the analysis and test of the fuel pump with rotors to evaluate its performance. It is analyzed the flow characteristics of the fuel pumps with numerical simulation in their inlet-outlet angles of 0, 15, 30 degree. After it is determined whether it has the best flow characteristics, its vibration characteristics is analyzed. The flow rate of a pump in the inlet-outlet angles of 0 degree is 191.0 LPH(Liter per hour) which is the largest. and its vibration is calculated to be 0.866 $^m/s^2$. In the results of vibration test, it is known that the vibration of the research pump is smaller than that of the existing one. And the natural frequencies of two pumps is nearly same. Therefore it is known that the performance of the research pump is superior.

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.

Vibration Performance test and static load test of body flat freight car (평판화차의 차체 정하중시험 및 진동성능시험)

  • Hong Jai-Sung;Ham Young-Sam;Kim Gil-Dong;Han Suk-Youn;Cha Ji-Bum
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.700-705
    • /
    • 2003
  • The object of this study is to ensure the stability of flat freight cars using vibration performance test and static load test of body structures. We examined the flat car though static load test and dynamic characteristics analysis related traveling stability and vibration performance. In the results of static load test of body structures for flat car, all structures satisfied allowable stress of materials. The vibration performance test was satisfied with allowable standards. Although flat car exceed speed a little at some speed interval, it was estimated that the cause was not cars but rail.

  • PDF

Ground Vibration Tests of SmartUAV Airframe Structure (스마트무인기 기체구조물 지상진동시험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Jung-Jin;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • This paper describes the test procedure, instrumentation, verification methodology and the results of the ground vibration test(GVT) and force vibration test(FVT) of the SmartUAV aircraft to estimate experimentally dynamic characteristics of the aircraft. Bungee cords are used to emulate free-free boundary conditions of the test aircraft. The SmartUAV is excited by three shakers and one-hundred frequency response functions(FRF's) is measured. The FRF's are reduced and analyzed to identify the dynamics parameters of the SmartUAV. To extract modal parameters of the SmartUAV such as, natural frequencies and damping ratios, the poly-reference least square complex exponential method is used in the time domain. The mode shape coefficients are estimated with the least squares frequency domain method to identify the vibration modes. The FVT was performed by fixed sine frequency with three shakers on the x, y and z direction and vibration characteristics of structures and detail equipments are measured.

Ground Vibration Test for Korean Utility Helicopter (한국형 기동헬기 전기체 지상진동시험)

  • Kim, Se-Hee;Kwak, Dong-Il;Jung, Se-Un;Choi, Jong-Ho;Kim, Joung-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.495-501
    • /
    • 2013
  • Korean Utility Helicopter (KUH) has been designed to avoid the blade passing frequency and any instability due to a coupling of dynamic characteristics between the main rotor and the airframe in ground operation. For these design objectives, the vibration analysis and the ground resonance analysis were performed to analyze the dynamic characteristics of the airframe and the main rotor. Then, the whirl-tower test was conducted to identify the dynamic characteristics of the main rotor and the ground vibration test (GVT) was conducted to identify the dynamic characteristics of the airframe. The GVT for KUH was conducted with the test conditions and test articles established in consideration of each flight and ground condition. This paper shows the method and technique for performing the GVT for KUH and presents the correlation technique and the results for the correlated analysis model.

Vibration reduction in a Hull mount using the ER inserts (ER 인서트를 이용한 Hull Mount 에서의 진동저감에 관한 연구)

  • Kim, Ji-Seon;Kim, Jae-Hwan;Choi, Seung-Bok;Kim, Kung-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.453-458
    • /
    • 2002
  • This paper deals with the vibration reduction of hull mount system of ship structures brought by ER smart structures. The hull mount is used to isolate the vibration of equipment from the host structures. Utilizing the tunable characteristics of ER fluids, ER inserts are made in the hull mount structure. Different types of ER inserts are proposed and the vibration characteristics are investigated. A hull mount structure is made and the influence of ER inserts are experimentally studied. An extensive modal test is empirically conducted to identify natural frequencies and mode shapes according to the applied electric field and the types of ER insert. The frequency tunable characteristics of ER inserts can be applied to many mounting structures for vibration reduction.

  • PDF

Natural Vibration Period of Small-scaled Arch Structure by Shaking Table Test (진동대실험을 통한 축소 아치구조물의 고유진동주기 분석)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.4
    • /
    • pp.107-114
    • /
    • 2015
  • Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.