• Title/Summary/Keyword: Vial

Search Result 180, Processing Time 0.02 seconds

Constituent Analysis of Organic Solvents in Adhesives Sold on Domestic Market (국내시판 본드에 함유된 유기용매의 성분분석)

  • Kim, Dai-Byung;Lee, Jong-Kwon;Jung, Kyong-Ja;Yoon, Yeo-Pyo;Kim, Myung-Soo
    • Toxicological Research
    • /
    • v.14 no.3
    • /
    • pp.329-332
    • /
    • 1998
  • Ingredients and concentrations of organic solvents in 7 kinds of adhesive sold on the domestic market were qualitatively and quantitatively analysed. Vapor concentrations were also analysed to estimate inhalation concentratins when adhesives were abused to get high. Acetone, methyl ethyl ketone, methyl cyclopenatane, cyclohexane and toluene were identified to be used in domstic adhesives as solvents. When organic solvents of adhesives were vaporized in the vial at the room temprature for 30 mins, concentrations of organic solvents in air were in the range of 5,000~140,000ppm. Among these solvents, toluene, known to have strong hallucination effect, showed 5,000~35,000 ppm. The putative concentration of toluene in case of glue sniffing was estimated to be about 5,000ppm in consideration of glue sniffing circumstances. Toluene was found in all adhesives in this study, even adhesives which toluene was not described in label.

  • PDF

Cometabolism of Trichloroethylene by a Phenol-Degrading Bacterium, Pseudomonae sp. EL-04J (페놀분해세균인 Pseudomonas sp. EL-04J에 의한 Trichloroethylene의 공동대사)

  • Kim, Ho-Seong;Park, Geun-Tae;Son, Hong-Ju;Park, Seong-Hun;Lee, Sang-Jun
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.359-364
    • /
    • 2001
  • Pseudomanas sp. EL-04J was previously isolated from phenol-acclimated activated sludge. This bacterium was capable of degrading phenol and cometabolizing trichloroethylene (TCE). After precultivation in the mineral salts medium containing phenol as a sole carbon source, Pseudomonas EL-04J degraded 90% of TCE $25 \mu\textrm{M}$ within 20 hours. Thus, phenol-induced Pseudomonas sp. EL-04J cells can bdegrade TCE. Followsing a transient lag period, Pseudomonas sp. EL-04J cells degraded TCE at concentrations of at least $250 \mu\textrm{M}$ with no apparent retardation in rate, but the transformance capacity of such cells was limited and depended on the cell concentration. The degradation rate of TCE followed the Michaelis-Menten kinetic model. The maximum degradation ratio ($V_{max}$) and saturation constant ($K_{m}$) were $7nmo {\ell}/min{\cdot}mg$ cell protein and $11 \mu\textrm{M}$, respectively. Cometabolism of TCE by phenol fed experiment was evaluated in $50m {\ell}$ serum vial that contained $10m {\ell}$ of meneral sals medium supplemented with $10 \mu\textrm{M}$ TCE degradation was inhibited in the initial period of 1 mM phenol addition, but after that time Pseudomonas sp. EL-04J cells degraded TCE and showed cell growth.

  • PDF

Development of Simulated HPGe Detector Spectrum for Education (교육용 모사 HPGe 검출기 스펙트럼 개발)

  • Seo, Kyung-Won;Lee, Mo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • From HPGe calibration spectrum of liquid mixed source in cylindrical vial, we developed simulated spectrum for spectrum analysis education. It is the spectrum that combine peaks separated from measured spectrum. After that, spectrum removed statistical variation of channel counts. Statistical fluctuation of the spectrum is made by Box-Muller function. The spectrum contains 18 peaks. The peak's centroid and area were defined exactly. Developed spectra are calibration spectrum, sample spectrum, background spectrum and spectra for efficiency correction for geometry and cascade coincidence.

EXPERIMENTAL STUDY OF OPTIMUM DRYING CONDITION IN THE PROCESS OF SPRAY FREEZE DRYING (분무동결건조과정의 최적 건조조건 도출에 관한 실험적 연구)

  • Park, Kyong-Won;Song, Chan-Ho;Song, Chi-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1321-1326
    • /
    • 2008
  • A study on the heat and mass transfer for the drying time in spray freezing drying process was experimentally presented in this paper. A spray freezing dryer for the production of an inhalable powder medicine is developed and an albumin solution as protein specimen is adopted. The freeze-drying for the albumin solution is tested in three different height of the particles piled up in a tray such as 2 mm, 5 mm, 7 mm, and the drying time is estimated as 10 h, 15 h, 22 h. From this results, the correlation is suggested and the drying time with various height of the particles piled up in a tray can be estimated. The assessment on the drying time is conducted thought a microbalance and the rate of water content is measured. The results based on temperature and weight are compared. The difference of the results happens due to the heat transfer from the lateral side of the vial. It is thought that the better estimation in drying time can be predicted by considering the heat transfer effect.

  • PDF

Effect of Degrees of Powder Mixing on the Synthesis of $Ti_3Si$ and $TiSi_2$ by Mechanical Alloying (기계적 합금화시 $Ti_3Si$$TiSi_2$ 합성에 미치는 분말 혼합도의 영향)

  • 변창섭
    • Journal of Powder Materials
    • /
    • v.6 no.1
    • /
    • pp.103-110
    • /
    • 1999
  • Different sizes of Si powder and milling medium materials (steel and partially stabilized zirconia (PSZ)) were used to synthesize $Ti_3Si$ and $TiSi_2$ by mechanical aollying (MA) of Ti-25.0.at.%Si and Ti-66.7at.% Si powder mixtures. the formation of each titanium silicide did not occur even after 360 min of MA of as-re-ceived Si and Ti powder mixtures due to the lack of homogeneity. $Ti_3Si$, however, was synthesized after 240 min of MA of Ti and 60 min-premilled Si powder mixture. ${\alpha}-TiSi_2$ and $TiSi_2$ were produced by jar milling of Ti and 60 min-premilled Si powder mixture for 48 hr and high -energy PSZ ball-milling in a steel vial for 360 min. The formation of each titanium silicide was characterized by a slow reaction rate as the reactants and product(s) coexisted for a certain period of time. The formation of $Ti_3Si$ and $TiSi_2$ and the reaction rates appeared to be influenced by the Si particle size, the homogeneity of the powder mixtures and the milling medium materials.

  • PDF

Reduction of Hexavalent Chromium Collected on PVC Filters in Field Electroplating Process (현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원)

  • Shin Yong Chul;Paik Nam Won;Yi Gwang Yong;Lee Byung Kyu;Lee Ji Tae
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • Recently, pilot studies showed an evidence of reduction of airborne hexavalent chromium, Cr(VI), on PVC filter during air sampling and storage. However, the information on this in the field was limited. Thus, we studied the reduction behaviors of airborne Cr(VI) on PVC filters during sampling and storage at three field electroplating operations. Regression between sampling time and the reduction (ratio of Cr(VI) to total Cr concentrations) was not statistically significant (p>0.05). However, the reductions in samples collected for 240 ~ 340 minutes were significantly higher than those for 30 - 60 minutes. On the other hand, another experiment showed a good correlation (r=0.96) between sampling time and the reduction without an exceptional value. Storage temperature was not a factor affecting the reduction of Cr(VI) collected on PVC filter. The loss of Cr(VI) samples stored in alkali solution (2% NaOH/3% Na$_2$CO$_3$) was significantly lower than that stored in vial according to NIOSH method (p<0.05). Thus, dipping Cr(VI) samples into alkali solution was a storage method to minimize tile reduction.

The Stability of Ceftriaxone Sodium Injection with the Various Storage Methods after Reconstitution (Ceftriaxone Sodium 주사제 조제후 보관방법에 따른 안정성)

  • Oh, Eun Joo;Park, Kwang Joon;Shin, Hyun Taek;Lee, Sukhyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.1
    • /
    • pp.54-58
    • /
    • 1998
  • The stability of ceftriaxone sodium 100 mg/ml in the water for injection was tested at two temperature conditions (refrigerator and room temperature) and two storage containers (vitro and syringe). The stability of each sample was determined by high-performance liquid chromatography while storing for 5 days at room temperature and 27 days at refrigerator. The concentration of ceftriaxone sodium was 100 mg/ml which the hospital usually use as a filling preparation for I.V. push or Y-site injection. There was no significant difference between the storage in vials and syringes. There was no significant difference in the change of concentration until storing the reconstituted ceftriaxone sodium injection for 2 days at room temperature and 14 days at refrigerator. In conclusion, the ceftriaxone sodium 100 mg/ml in the water for injection can be stored in vial or syringe for 2 days at room temperature and 14 days at refrigerator after preparation.

  • PDF

Effect of high energy ball milling on the structure of iron - multiwall carbon nanotubes (MWCNT) composite

  • Kumar, Akshay;Pandel, U.;Banerjee, M.K.
    • Advances in materials Research
    • /
    • v.6 no.3
    • /
    • pp.245-255
    • /
    • 2017
  • High energy ball milling is employed to produce iron matrix- multiwall carbon nanotube (MWCNT) reinforced composite. The damage caused to MWCNT due to harsh ball milling condition and its influence on interfacial bonding is studied. Different amount of MWCNT is used to find the optimal percentage of MWCNT for avoidance of the formation of chemical reaction product at the matrix - reinforcement interface. Effect of process control agent is assessed by the use of different materials for the purpose. It is observed that ethanol as a process control agent (PCA) causes degradation of MWCNT reinforcements after milling for two hours whereas solid stearic acid used as process control agent, allows satisfactory conservation of MWCNT structure. It is further noted that at a high MWCNT content (~ 2wt.%), high energy ball milling leads to reaction of iron and carbon and forms iron carbide (cementite) at the iron-MWCNT interface. At low percentage of MWCNT, dissolution of carbon in iron takes place and the amount of reinforcement in iron matrix composite becomes negligibly small. However, under the present ball milling condition (ball to metal ratio~ 6:1 and 200 rpm vial speed) iron-1wt.% MWCNT composite of good interfacial bonding can retain the tubular structure of reinforcing MWCNT.

Development of Movable Detection System for Efficiency Measurement in 3-PM Liquid Scintillation Counting

  • Hwang, H-Y;Kwak, S.I;Cho, Y.H;Byun, J.I;Lee, H.Y;Seo, J.S;Kwak, J.Y;Lee, J.M;Lee, K.B;Park, T.S;Chung, K.H;Lee, C.W
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.165-170
    • /
    • 2003
  • We developed an improved 3-PM liquid scintillation counting (3-PM LSC) method in which three detectors can be displaced to back and forth directions, and a data acquisition system being able to provide the values for all parameters required for the method. The detectors are entirely located in a 20-mm lead chamber of an inner diameter of 500 mm. A saw-toothed gear ties up all detectors so as to move them uniformly, up to 50 mm with unit of 1 mm. The data acquisition system was designed in an integrated circuit to perform the necessary works such as fast amplification, discrimination, coincidence and logic analysis. It generates values of nine parameters among twelve's generated in the 3-PH LSC method. The dead time of each counting channel is of extending type, valving from 10 to 100 $mutextrm{s}$. We measured the TDCR values with an unquenched liquid scintillation source 1"C by displacing the detectors with a step of 2.5 mm away from counting vial. Their values were derived on the range from 0.9 to 0.6. The extent is three times wider than those regions observed by applying the defocalization technique.ique.

Thermoelectric and Transport Properties of FeV1-xTixSb Half-Heusler System Synthesized by Controlled Mechanical Alloying Process

  • Hasan, Rahidul;Ur, Soon-Chul
    • Electronic Materials Letters
    • /
    • v.14 no.6
    • /
    • pp.725-732
    • /
    • 2018
  • The thermoelectric and transport properties of Ti-doped FeVSb half-Heusler alloys were studied in this study. $FeV_{1-x}Ti_xSb$ (0.1 < x < 0.5) half-Heusler alloys were synthesized by mechanical alloying process and subsequent vacuum hot pressing. After vacuum hot pressing, a near singe phase with a small fraction of second phase was obtained in this experiment. Investigation of microstructure revealed that both grain and particle sizes were decreased on doping which would influence on thermal conductivity. No foreign elements pick up from the vial was seen during milling process. Thermoelectric properties were investigated as a function of temperature and doping level. The absolute value of Seebeck coefficient showed transition from negative to positive with increasing doping concentrations ($x{\geq}0.3$). Electrical conductivity, Seebeck coefficient and power factor increased with the increasing amount of Ti contents. The lattice thermal conductivity decreased considerably, possibly due to the mass disorder and grain boundary scattering. All of these turned out to increase in power factor significantly. As a result, the thermoelectric figure of merit increased comprehensively with Ti doping for this experiment, resulting in maximum thermoelectric figure of merit for $FeV_{0.7}Ti_{0.3}Sb$ at 658 K.