• 제목/요약/키워드: Vial

검색결과 180건 처리시간 0.024초

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

동결정액 포장방법이 돼지정액의 성상 및 번식성적에 미치는 영향 (Effect of Packing Materials of Frozen Boar Semen on Sperm Characteristics and Reproductive Performance)

  • 김인철;이장희;김현종;이성호;박창식
    • 한국가축번식학회지
    • /
    • 제26권2호
    • /
    • pp.119-124
    • /
    • 2002
  • 본 연구는 돼지에서 동결정액을 이용한 번식능력을 개선하기 위한 동결정액 포장재료의 효과를 구명하기 위하여 실시하였다. 본 시험에는 축산기술연구소 종축개량부 (충남, 성환)의 인공수정센터에서 사육중인 종모돈이 사용되었다. 기존의 돼지 동결정액 포장방법인 maxi-straw 동결정액 포장방법과 5$m\ell$빈 cryogenic-vial 및 aluminum-pack 포장방법을 비교한 결과 cryogenic-vial로 포장하여 액체질소 상단 15cm에서 동결한 후 52$^{\circ}C$ water bath에서 190초 융해한 방법이 기존의 maxi-straw 방법과 비슷한 결과를 나타내었다. Cyogenic-vial 포장방법의 동결-응해 방법을 설정하기 위하여 융해시간을 달리하여 시험한 결과 액체질소 상단 15cm에서 동결하고 52$^{\circ}C$에서 190초 간 융해하였을 때 정자운동성이 120초 및 150초 응해시 보다 우수하였다 (P<0.05). 그러나 정상첨체비율은 응해시간 간에 차이가 없었다. 52$^{\circ}C$에서 45초간 응해 한 maxi-straw 포장방법과 52$^{\circ}C$에서 190초 융해한 cryogenic-vial 포장방법간에 정액성상을 비교한 결과 총정자운동성과 정자의 빠르기는 maxi-straw가 우수하였다 (P<0.05). 그러나 직진성과 정상첨체비율은 두 포장방법간에 차이가 없었다. 동결정액 포장방법별 인공수정시 번식성적은 maxi-straw 동결정액이 cryogenic-vial 동결정 액보다 수태율, 분만율, 그리고 산자수가 높았으나 통계적 유의차는 인정되지 않았다. 이상의 결과를 종합해 보면 cryogenic-vial 포장 방법의 동결 및 음해방법을 좀 더 연구개발하면 기존의 maxi-straw포장방법을 대체하여 실용화 할 수 있을 것으로 사료된다.

동결정액의 포장방법이 정액성상과 번식성적에 미치는 영향

  • 김인철;이장희;김현종;김종대;연성흠;정경용;손동수;박창식
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2001년도 춘계학술발표대회
    • /
    • pp.77-77
    • /
    • 2001
  • 본 연구는 돼지 동결정액의 번식성적을 개선코자 기존의 maxi-straw와 cryogenic-vial을 이용하여 포장방법에 따른 동결방법과 융해방법별 정액성상 및 번식성적을 비교하였다. 동결방법은 두 가지 포장방법 모두 정액의 양(5$m\ell$)과 농도(5.0$\times$$10^{9}$/dose)가 동일한 조건으로 처리하였으며, LYE(Lactose egg york extender) 보존액으로 희석하여 액체질소 상단 15cm에서 20분간 동결하였다. 융해방법은 maxi-straw는 52$^{\circ}C$에서 45초간 cryogenic-vial은 52$^{\circ}C$에서 190초간 융해하여 $25^{\circ}C$로 가온 된 80$m\ell$ BTS (Beltsville thawing solution) 보존액과 혼합하였다. 정액성상검사는 정자자동분석기(SAIS : Sperm Analysis Image System, Korea)를 이용하였다. 총활력(TM : Total motility)과 정자의 빠르기(VCL : Curve linear velocity)는 maxi-straw가 54.3%와 46.6%로 cryogenic-vial의 35.6%와 36.6%보다 우수하였다(P<0.05). 정자의 직진성(STR : Straightness)과 NAR은 maxi-straw가 53.2%와 32.6%로 cryogenic-vial의 47.3%와 29.8%와 비슷한 경향을 나타내었다. 수태율과 분만율 및 총산자수는 maxi-straw가 77.3%, 68.2% 및 8.0두로 조사되어 cryogenic-vial포장방법의 66.7%, 61.9% 및 7.4두보다 다소 우수하였으나 통계적인 유의차는 인정되지 않았다. 이상의 결과로 볼 때 cryogenic-vial방법이 새로운 돼지 동결정액 포장방법의 가능성을 나타낸다고 사료된다.

  • PDF

DNA 검출 공정 전용 플라스틱 튜브형 시험관 개발에 관한 연구 (A study on development of plastic vial tube for the DNA detection process)

  • 최규완;라문우;강정희;장성호
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.35-40
    • /
    • 2017
  • PCR(Polymerase chain reaction) is a technique to replicate and amplify a desired part of DNA. It is used in various aspects such as DNA fingerprint analysis and rare DNA amplification of an extinct animal. Especially in the medical diagnosis field, it provides various measurement methods at the molecular level such as genetic diagnosis, and is a basic tool for molecular diagnostics. The internal shape of the plastic vial tube for PCR analysis used in the DNA detection process, and the surface roughness and internal cleanliness can affect detection and discrimination results. The plastic vial tube demanded by the developer of the PCR analysis equipment should be changed to a structure that eliminates the residual washing solution in the washing process to ensure the internal cleanliness. Thus the internal structure and the internal surface design for improving the PCR amplification efficiency are key issues to develop the plastic vial tube for the DNA detection process.

닫힌 바이얼 안에서 Pseudomonas putida에 의한 톨루엔 분해 (Toluene Degradation by Pseudomonas putida in Closed Vial)

  • 김희정;김인호
    • KSBB Journal
    • /
    • 제16권4호
    • /
    • pp.356-359
    • /
    • 2001
  • 톨루엔을 분해하는 대표적인 미생물로 알려진 Pseudomonas putida를 이용하여 생분해 특성을 살펴보고자 하였다. 톨루엔은 물에 대한 용해도가 매우 낮기 때문에, 호기적 조건으로 배양하는데 어려움이 있다. 톨루엔을 포함하는 배지를 포함한 닫힌 계를 이용함으로써, 반응기 내에서의 톨루엔 분해와 미생물 성장에 관해 살펴보았다. 초기에 액상으로 접종하는 톨루엔의 농도를 변화시켰고, 이에 따른 headspace에서의 톨루엔의 농도와 미생물 균체 농도 변화를 측정하였다. 닫힌계에서의 톨루엔 생분해에 관한 물질 수지식을 세우고 이를 전산 모사함으로써, 실험 값과 비교 분석하였다. Pseudomonas putida의 resting cell을 이용하면 닫힌 계에서도 톨루엔을 분해할 수 있었고, 반응기 내에서 일어나는 현상을 매개 변수를 통해 고찰하였다.

  • PDF

Cryopreservation of Sporothalli of the Genus Porphyra (Bangiales, Rhodophyta) from Korea

  • Jo, Young-Hyun;Kang, Sung-Pil;Seo, Tae-Ho;Choi, Sung-Je;Kho, Kang-Hee;Kuwano, Kazuyoshi;Saga, Naotsune;Kim, Min-Yong;Shin, Jong-Ahm
    • ALGAE
    • /
    • 제18권4호
    • /
    • pp.321-331
    • /
    • 2003
  • Cryopreservation of sporothalli of the red alga Porphyra (P. seriata, P. yezoensis, P. tenera, P. pseudolinearis and P. dentata) was performed by the two-step cooling method in liquid nitrogen. The algal samples were suspended in various cryoprotective solutions, and slowly cooled to -40$^{\circ}C$ in 4 hours using a programmed freezer. After the first slow cooling the suspensions with cryoprotectants were immediately immersed in liquid nitrogen. The suspension from the programmed freezer was thawed quickly by agitation of the vial in a water bath at 40°C. When ice in the suspension of cryogenic vial was mostly melted, the vial was transferred to an ice bath for complete melting of the residual ice. The cryoprotectants in the vial were washed off by gradual dilution with seawater. The viability of the cell was assessed with neutral red staining. The viability of Porphyra samples ranged 54.6-70.9% when the mixed suspension of 10% dimethylsulfoxide and 0.5 M sorbitol in 50% seawater used as a cryoprotectant.

The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image

  • Cho, Yong-Hyun;Park, Jun-Hyung;Hwang, Ki-Young;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.74-77
    • /
    • 2008
  • The radiopharmaceuticals are routinely injected to blood vessel for acquiring PET image. For this reason, It is imperative that they undergo strict quality control measures. Especially, Sterility test is more important than any other quality control procedures. According to the FDA guideline, It requires filter integrity test used in the processing of sterile solutions. Among several methods, we can decide to use bubble point test. We usually use vented GS-filters (Millipore co., USA) which are sterilizinggrade (0.22 um pore size) and are placed upper site on product vial. After the synthesis of $^{18}F$-FDG, solutions wet the membrane in filter and then go into the product vial. By all synthesis steps have finished, we can observe the presence of the bubbles in the product vial. Since we have started this study, we have never found any bubbles in the product vial. Because the maximum pressure intensity of the filter which has set by manufacturer is up to 5 bars, but helium gas pressure is up to 1 bar in our module system. So, we can make 5 bars pressure using helium gas bombe and increase pressure up to 5 bars step by step. However, it does not happen to anything in vial.

  • PDF

온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 - (Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide)

  • 정재학;임호수;김기현;배위섭;전의찬
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.

Sandwich ELISA 방법을 이용한 숙주유래 단백질의 검출

  • 성혜윤;김창민;민홍기;용군호
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1994년도 춘계학술대회 and 제3회 신약개발 연구발표회
    • /
    • pp.254-254
    • /
    • 1994
  • 현재 국내에서 시판되고 있는 생물공학 의약품매 혼입될수 있는 숙주유래 단백질을 검출하기 위하여 숙주계로 사용되고 있는 Saccaromyces cerevisiae KCTC 1720과 Escherichis coli k12의 total protein을 분리 정제하여 토끼와 guinea pig으로부터 total protein 항체를 얻었다. 이때 토끼항체의 단백질 농도는 yeast의 경우에 4.05mg/m1, E. coli의 경우에 7.14mg/m1이었고, guinea pig의 단백질농도는 yeasat의 경우에 1.90mg/m1이었고 E. coli의 경우에 7.17mg/m1이었다. S. cerevisiae와 E. coli를 숙주로 하여 생산된 생물공학 의약품의 숙주유래 단백질을 검출하기 위하여 guinea pig항체를 96 well microptate에 흡착시키고 검체와 토끼항체의 순으로 microplate에 첨가하는 방법인 sandwich ELISA방법올 사용하였다. 이 방법을 생물공학 의약품의 숙주유래 단백질 검출에 적용한 결과 사람 성장 호르몬의 경우에는 5ng/vial 이하로 검출되었다. 또한 생물학적 제제 생물공학 제품의 경우에는, B형 간염백신제재와 인터페론 감마는 1ng/vial 이하로 검출되었고 인터페론 알파의 경우에는 25ng/vial이하로 검출되었다. 또한 이 방법은 현재 개발되어 시판되고 있는 생물공학 의약품 내에 혼입된 숙주유래 단백질을 검출하는데 쓰일 것이다.

  • PDF

다공성 물길의 진공동결건조과정에서 얼 및 물질전달 특성에 관한 연구 (A Study on the Heat and Mass Transfer Characteristics of Vacuum Freeze Drying Process for Porous Media)

  • c. s. song
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1341-1352
    • /
    • 2001
  • Vacuum freeze drying process by which frozen water in a drying material is removed sublimation under vacuum condition, is now applied to various industrial field such as the manufacturing and packaging of pharmaceuticals in pharmaceutical industry, the drying of bio- products in bio-technology industry, the treatment of various quality food stuff in food technology, and so on. The Knowledge about the heat and mass transfer characteristics related with the vacuum freeze drying process is crucial to improve the efficiency of the process as well as the quality of dried products. In spite of increasing needs for understanding of the process, the research efforts in this fields are still insufficient. In this paper, a numerical code that can predict primary drying in a vial is developed based on the finite volume method with a moving grid system. The calculation program can handle the axis- symmetric and multi-dimensional characteristics of heat and mass transfer of the vial freeze drying process. To demonstrated the usefulness of the present analysis, a practical freeze drying of skim Milk solution in a vial is simulated and various calculation results are presented.

  • PDF