• Title/Summary/Keyword: Very low frequency

Search Result 1,385, Processing Time 0.033 seconds

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1100-1107
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Modification and Testing to Prevent the Resonance in a Finger-type Low Pressure Turbine Blade (저압 터빈용 Finger 형 블레이드의 공진 방지를 위한 개선 및 시험)

  • Ha, Hyun-Cheon;Lee, Dong-Jin;Ryu, Seok-Ju;Chung, Hee-Chan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.612-617
    • /
    • 2000
  • This paper describes the experience gained from the treatments for prevention of blade failure occurred in the low-pressure turbine. Some cracks due to high cycle fatigue were found at the blades in low-pressure turbines after long time operation. Such failure was mainly caused by the resonance of the blade with the vane passing frequency excitation. If a natural frequency of the blade exists near the excitation frequency, a resonant vibration can occur and leads to a large amount of stress which may cause fatigue failures in turbine blades. To avoid the resonance of the blade, some modifications have been performed and full-scaled mockup testing has been done to confirm the verification for modification. Test result shows that enlarging the span cover is very useful to change the natural frequency of the grouped blades effectively.

  • PDF

Optimal Design of Nonlinear Hydraulic Engine Mount

  • Ahn Young Kong;Song Jin Dae;Yang Bo-Suk;Ahn Kyoung Kwan;Morishita Shin
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.768-777
    • /
    • 2005
  • This paper shows that the performance of a nonlinear fluid engine mount can be improved by an optimal design process. The property of a hydraulic mount with inertia track and decoupler differs according to the disturbance frequency range. Since the excitation amplitude is large at low excitation frequency range and is small at high excitation frequency range, mathematical model of the mount can be divided into two linear models. One is a low frequency model and the other is a high frequency model. The combination of the two models is very useful in the analysis of the mount and is used for the first time in the optimization of an engine mount in this paper. Normally, the design of a fluid mount is based on a trial and error approach in industry because there are many design parameters. In this study, a nonlinear mount was optimized to minimize the transmissibilities of the mount at the notch and the resonance frequencies for low and high-frequency models by a popular optimization technique of sequential quadratic programming (SQP) supported by $MATLAB^{(R)}$subroutine. The results show that the performance of the mount can be greatly improved for the low and high frequencies ranges by the optimization method.

The Properties of Transmission in the High Foamed Coaxial Cable (고발포 동축케이블의 전송특성)

  • 김성탁;박대희;김용주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.77-80
    • /
    • 1998
  • Recently, extending the local broadcasting and increasing lots of informations. The low-loss communication cable is required in proportion as frequency .The reason of transportation loss causes to using the high frequencies like hundreds of MHz or decades of GHz. For the low transportation loss. It is required the developing-technology of foaming and the high foamed insulator with the dielectric ratio of the nearest to 1. Therefor, there is the purpose of developing the insulating materials for the low dielectric ratio. Also it is important to measure the attenuation, which is one of the important parameters.sa the evaluation of transportation characteristic with frequency in the communication cable. In this paper,the result showed that the dielectric ratio(1.4) of the nearest to 1 and low attenuation with high frequency were very related to the transportation and reflection characteristics such as propagation velocity (82.27%). Delay time and voltage standing wave ratio(VSWR).

  • PDF

Optimal layout of exhaust systems for the reduction of low-frequency noise (저주파수 배기소음 저감을 위한 배기계 배치의 최적화)

  • 장승호;이정권;채성수;김정태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.623-627
    • /
    • 2001
  • Suppression of very low-frequency noise from an automobile exhaust system is difficult due mainly to its large wave length. Therefore, the configuration of total exhaust system, i,e., piping and muffler layout, is important at low frequencies. In this paper, an optimal layout technique of exhaust systems has been developed for reducing low-frequency exhaust noise. For this purpose, system insertion loss and virtual attenuation coefficient have been defined by considering the effects of mean flow and temperature gradient in the pipe. The applicability of present method is investigated with an actual automobile exhaust system and an optimized layout of pipes and mufflers is suggested.

  • PDF

100W On-Board Power Supply Using Flat Transformer (Flat Transformer를 이용한 100W급 On-Board Power Supply)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

Evaluation on Dynamic Behavior of Friction Welded Joints in Alloy718 to SCM440 using Acoustic Emission Technique (Alloy718/SCM440 마찰용접재의 AE에 의한 동적 거동평가)

  • Kim, Dong-Gyu;Kong, Yu-Sik;Lee, Jin-Kyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.491-497
    • /
    • 2019
  • Dissimilar friction welding were produced using 15 mm diameter solid bar in superalloy(Alloy718) to chrome molybdenum steel(SCM440) to investigate their mechanical properties. Consequently, optimal welding conditions were n=2000 rpm, HP=60 MPa, UP=120 MPa, HT=10 sec and UT=10 sec when the metal loss(Mo) is 3.5 mm. Acoustic Emission(AE) technique was applied to analyze the dissimilar friction welding of Alloy718 and SCM440. The relationship between the AE parameters and dissimilar friction welding of both material was discussed. In the case of heating time of 6 sec, 10 sec, 14 sec and 20 sec, 5 AE events per 0.5 seconds and energy about $2.7{\times}10^{10}$ were exhibited in heating time. In upsetting time, resulting in various numbers of events per second and very low energy. The frequency range of the signal generated during the heating time was about 200 kHz. However, the upsetting time resulted in a wide range of signals from very low frequency to high frequency of 500 kHz due to rapid plasticity of the material.

Defects Detection of the Underground Distribution Power Cables by Very Low Frequency Voltage Source (초저주파전원을 이용한 지중배전 전력케이블의 결함검출)

  • 김주용;송일근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.45-50
    • /
    • 1998
  • This paper presents experimental results on the application of very low frequency(VLF) voltage to replace conventional DC test as an after laying test for underground distribution cables. We carried out several tests to prove defects detecting ability of VLF test on the 5m length real cables having knife-cut or needle type defects which is made in our La.. Through this experiment we proved it is very difficult to initiate electrical tree from the defects inside of the cable insulation but once the electrical tree is initiated it grows very fast and VLF does not make new defects and expand the defect. Therefore VLF test equipment for quality inspection test of manufacture is more effective than field application for underground distribution cables.

  • PDF

Model Order Reduction for Mid-Frequency Response Analysis (중주파수 응답해석을 위한 축소 기법)

  • Ko, Jin-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.135-138
    • /
    • 2009
  • Most of the studies use model order reduction for low frequency (LF) response analysis due to their high computational efficiency. In LF response analysis, one of model order reduction, algebraic substructuring (AS) retains all LF modes when using the modal superposition. However, in mid-frequency (MF) response analysis, the LF modes make very little contribution and also increase the number of retained modes, which leads to loss of computational efficiency. Therefore, MF response analysis should consider low truncated modes to improve the computational efficiency. The current work is focused on improving the computational efficiency using a AS and a frequency sweep algorithm. Finite element simulation for a MEMS resonator array showed that the performance of the presented method is superior to a conventional method.

  • PDF