• 제목/요약/키워드: Very Low Temperature

검색결과 1,918건 처리시간 0.145초

저온냉각공구의 절삭특성 변화 (제1보) -모터 회전자의 절삭특성 (On Cutting Characteristics Change of Low Temperature Cooling Tool(1st Report) - Cutting Characteristics of Cage Motor Rotor -)

  • 김순채;김희남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.44-48
    • /
    • 1994
  • The cutting process of cage motor rotor require high precision and good roughness. The surface roughness of cutting face is very important factor with effect on the magnetic flux density of cage motor rotor. The paper describes a cause of decrease in the cutting force and roughness on low temperature cooling tool by means of analysis on the mechanism of force system at cutting confition and experimental findings. The main results as compared with the room temperature cutting are as follow : 1) The cutting resistance decreased due to low temperature cooling tool. 2) The surface roughness decreased due to low temperature cooling tool.

  • PDF

충남탄전(忠南炭田) 무연탄(無煙炭)의 특성(特性) (Property of the Jurassic anthracite (Anthracite from the Seongju Area of the Chungnam Coalfield))

  • 박석환;박홍수
    • 자원환경지질
    • /
    • 제22권2호
    • /
    • pp.129-139
    • /
    • 1989
  • The anthracite coalfields of Korea are confined to the areas where sedimentary rocks of Permian and Jurassic are preserved. The Chungnam coalfield lies in the sedimentary rocks of Jurassic which belongs to the Daedong Supergroup (the Nampo group). For the property analysis of each coal seam interbeded in Daedong Supergroup, Seongju area is chosen and twelve coalseams are taken. Many standard tests have been established for optical analysis (maceral analysis, coalification degree measurement), chemical analysis (proximate, ultimate analysis) and physical analysis (ignition temperature, ash fusion temperature, hardgrove grindability index and X-ray diffraction). The Jurassic anthracite mainly consist of vitrinite and macrinite and the range of the reflectance is $R_{max}$ 5.0-6.5 which means metaanthracite rank. By the chemical composition analysis, it shows low H/C and high O/C value compare with international average value. By the physical analysis, it has very high ignition temperature ($531-584^{\circ}C$) and ash fusion temperature ($1510-1700^{\circ}C$) and very low combustion velocity (0.2-1.9 mg/min). The very wide range of the hardgrove grindability index (46-132) means that the grindability controlled mainly by the structural conditions of coal bearing strata.

  • PDF

니켈카드뮴 축전지의 성능시험 분석 (An Analysis of Performance Test Results for Nickel-Cadmium Battery)

  • 온정근;김명룡;김원경;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.600-605
    • /
    • 2003
  • Battery of rolling stock is a very important device as power supply at starting and emergency control. This paper analyzes the quality of Ni-Cd battery by means of performance test. Ni-Cd battery have suitable and stable properties. That is very stable to discharge on low temperature state and very easy to manage and repair. This paper confirm the performance and property of Ni-Cd battery on low temperature environment by the performance test and estimate the life-cycle of Ni-Cd battery on board at rolling-stock by the life-test and the using-test.

  • PDF

수산물의 저온진공건조 열적 특성에 관한 연구 - 해삼을 중심으로 - (A Study on the Thermal Characteristics of Aquatic Products by Low Temperature Vacuum Drying - Especially on the Sea Cucumber -)

  • 최순열;김민수
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.46-51
    • /
    • 2011
  • Low temperature vacuum drying technique, whose drying time and quantity of exhausting energy is about 25~30% of hot air drying, is very excellent in the drying efficiency. This paper is made out in the aspects of heat engineering with the object of developing Korean drying machine which can dry once a large quantity of objects to be dried in the state of low temperature and vacuum. As the results, it took about 17 hours(3~4 days in case of hot air drying) for material to reach about 18% of the final moisture content in order to store products for a long time, from about 78~80% of the early moisture content at the beginning of drying, and maximum drying rate comes to about 0.35 kg/m2hr at about 400% of the moisture content.

농산물의 저온진공건조 열적 특성에 관한 연구 - 고추를 중심으로 - (A Study on the Thermal Characteristics of Agriculture Products in the Process of Low Temperature Vacuum Drying - With Cayenne as the Object Product for Drying -)

  • 최순열
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.44-49
    • /
    • 2001
  • Low temperature vacuum drying technique shows very excellent energy efficiency and prominent drying performances compared with the conventional hot air drying technique. This study was focused on the thermal characteristics of the low temperature vacuum drying technique. From the results of this study, it was confirmed that the time consumption for drying with the new drying technique could be shortened to about 1/3 of the time consumption with the conventional hot air drying technique under the same drying conditions for wet products. Also, the maximum drying rate with the new drying technique reached to about $0.35kg/m^2h$ at about 400% of moisture content.

  • PDF

저온조건하 스테인레스 강의 파괴 특성 (Fracture Characteristics of Stainless Steel Under Low Temperature Conditions)

  • 김두환;한석규;안세희
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.108-115
    • /
    • 1999
  • It has been recognized that the mechanical properties of structural steels can be accepted very greatly in a state of normal temperature. While, under low temperature conditions the properties of the structural steels may not be appropriately achieved. When the various and particular structures will be constructed in an intense cold region afterward, the mechanical properties of a stainless steel under low temperature condition must be investigated. The purpose of this paper is to account for the fracture mechanics of structures in the state of low temperatures. The fracture toughness was examined through an experimental test from which the tensile strength and impact values of STS 304 were obtained. In order to demonstrate the present studies, the fracture toughness was compared with the test results for SWS 50 published previously by an author.

  • PDF

pH- and Temperature-Sensitive Bifunctional Hydrogels of N-Isopropylacrylamide and Sulfadimethoxine Monomer

  • Lee, Jin-Woo;Lee, Doo-Sung;Kim, Sung-Wan
    • Macromolecular Research
    • /
    • 제11권3호
    • /
    • pp.189-193
    • /
    • 2003
  • pH- and temperature-sensitive bifunctional hydrogels composed of N-isopropylacrylamide (NiPAAm) and a sulfadimethoxine monomer (SDM) derived from sulfadimethoxine were prepared. These hydrogels exhibit simultaneous pH- and temperature-induced volume-phase transitions. The pH-induced volume-phase transition behavior is produced by the ionization/deionization of SDM and is very sharp. In the high pH region, the ionization of SDM induces swelling of the hydrogels. In the low pH region, the deionization of SDM induces deswelling of the hydrogels. The temperature-induced volume-phase transition behavior of the bifunctional hydrogels exhibits negative thermosensitivity because of the NiPAAm component. The hydrogels swell even at low pH as the temperature decreases. The hydrogels swell at low temperature and high pH, and deswell at high temperature and low pH. The volume of the hydrogels dependl on the balance of the swelling and deswelling produced by the two competing stimuli, pH and temperature.

액분사 사이클을 이용한 공기 열원 열펌프의 사이클 시뮬레이션 (Cycle Simulation of an Air Source Heat Pump Using Liquid Injection)

  • 김욱중;홍용주;남임우;강원일;공용상
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.244-250
    • /
    • 2000
  • An air source heat pump using liquid injection technique, which can be applied for very low temperature climate, has been simulated to examine the design options. Comparison between the simulation and experiment has been carried out to validate the simulation method. Effects of various design parameters such as liquid injection rate and injection pressure are Investigated to optimize the performance of the heat pump. Finally, optimal liquid infection rate and injection pressure to maintain sufficient heating capacity and moderate discharge refrigerant temperature are suggested when the heat pump was operated at very low outdoor temperature.

  • PDF

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

변형 연속회분식 반응기를 이용한 오수의 고도처리 (Advanced Sewage Treatment by the Modified SBR(Sequencing Batch Reactor) Process)

  • 김병군;서인석;홍성택;정위득
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.46-51
    • /
    • 2002
  • This study was performed to treat a sewage at the upper stream of dam using modified sequencing batch reactor, During the operating period, average $COD_{cr}$, removal efficiency was about 85% but average T-N and ${PO_4}^{3-}-P$ removal efficiencies were 43% and 30% respectively. Because the organic matter was very low compared with nitrogen and phosphorous in influent($BOD_{5}/{NH_4}^{+}-N{\;}={\;}2,{\;}BOD_{5}/{PO_4}^{3-}-P{\;}={\;}15.6$), nitrogen and phosphorus removal efficiency was relatively low. Average nitrogen removal efficiency was 50 % at $10^{\circ}C$ or above and it was 36 % at $10^{\circ}C$ or below. As reactor was located in outdoor without any thermostat, temperature decreased at least $2.4^{\circ}C$ in the winter season. Therefore, if we would apply this modified sequencing batch reactor to sewage which concentration of organic matter was very low compared with nitrogen and phosphorous, we have to addition of external carbon and installation of any thermostat.