• Title/Summary/Keyword: Very Low Temperature

Search Result 1,917, Processing Time 0.034 seconds

Effects of Resistivity Variation in a Very Low Temperature on the Characteristics of Induction Motors

  • Kim, Beom Jin;Kim, Jin Sung;Park, Gwan Soo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents design of induction motor in very low temperature for LNG main cargo pump and comparison of two motors. One is the motor for using in room temperature and another is the motor for using very low temperature. This paper designs with Equivalent circuit Method and uses Finite Element Method to analysis. The motor for very low temperature considers variation of coil resistivity due to temperature change and compare torque characteristic with the motor for room temperature. Design element of motor for very low temperature considers resistivity variation following temperature change on going through this paper. The result shows that two types of motors are almost same torque curve characteristic even though they are not the same environment.

The Influence of Storage at Very Low Temperatures on the Deterioration of Concrete (극저온 하에서의 일정 온도유지가 콘크리트의 열화에 미치는 영향)

  • 한상묵;조명석;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.667-672
    • /
    • 2002
  • Concrete cooled to very low temperature cyclically is deteriorated by ice formation in micro-pores. Although the factors to the deterioration are various, storage at very low temperature is mentioned as one of the factors. In practice, storage of cryogenic structure is kept at very low temperatures, and as such, it is important to take into consideration the influence of storage at such low temperature on the deterioration of concrete. Thus, in this study, the influence of storage on the deterioration of concrete at minimum temperatures taking into consideration the different W/C and air content.

  • PDF

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

Low-Temperature Deformation Behavior of a Stainless Steel for the Thrust Chamber Mixing Head (연소기 헤드용 스테인리스강의 저온 변형 거동)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.11
    • /
    • pp.1096-1103
    • /
    • 2009
  • The predictions of the material behavior for the structural stability of thrust chamber mixing head at very-low temperatures are very important since the head is highly pressurized by the liquid oxygen with very-low temperatures and experiences impact load by the thrust of combustion chamber. The constitutive equation to express tensile deformation behavior of the material at very-low temperature to predict deformation behavior of the mixing head is formulated by composition of thermal component and athermal component based on dislocation energy barrier model suggested by Kocks. Also, increase of thermal stress components by the increase of obstacles at low temperatures is formulated to the equation similar with Ramberg-Osgood equation. The suggested model predicted well the material's behavior at the wide temperature ranges from very-low temperature to ambient temperature.

Electronics processed at very low temperature (T<180$^{\circ}C$)

  • Mohammed-Brahim, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.951-952
    • /
    • 2009
  • The long way toward new silicon technology, processed at very low temperature on any substrate, is described. The technology is based on CMIS (Complementary Metal Insulator Semiconductor) structure that shown its efficiency with known CMOS electronics. Present performance of this new technology is discussed through electrical parameters and reliability of transistors.

  • PDF

On Cutting Characteristics Change of Low Temperature Cooling Tool -Cutting Characteristics of Cage Motor Rotor- (저온냉각공구의 절삭특성 변화 -모타 회전자의절삭특성-)

  • 김순채
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.37-43
    • /
    • 1995
  • The cutting process of cage motor rotor require high precision and good roughness, the surface roughness fo cutting face is very important factor with effect on the magnetic flux density of cage motor rotor. The paper describes a cause of decrease in the cutting force and roughness on low temperature cooling tool by means of analysis on the mechanism of force system at cutting condition and experimental findings. The main results as compared with the room temperature cutting are as follow : 1) The cutting resistance decreased due to low temperature cooling tool. 2) The surface roughness decreased due to low temperature cooling tool. 3) The low temperature cooling tool effected machinability of the cutting direction in machined surface. 4) The low temperature cooling decreased burr of corner in feed direction.

  • PDF

A Study on the Characteristics of the Suspension Components of Rolling Stocks in the Very low Temperature (극한 온도에서의 철도차량용 현가부품의 특성연구)

  • Choi, Byoung-Il;Na, Hee-Seung;Jang, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • This study is a preview of characteristics of (1st/2nd) rubber suspension parts in low temperature, it will be researched before Trans Korean Railway and continental railway network connection. Rubber material characteristics are different to steel materials. Behavior of rubber material shows large deformation in hyper-elastic region. Moreover, added dashpot and low temperature condition shows various non-linear characteristics.

  • PDF

Physicochemical and Microbial Characteristics of Oiji Prepared with Dry Salting Methods during Low Temperature Storage (저염 건식절임법으로 제조한 오이지의 저온저장 중 이화학적$\cdot$미생물학적 품질특성)

  • Kwon Oh-Yun;Yang Yun-Hyoung;Park Wan Soo;Kim Mee Ree
    • Korean journal of food and cookery science
    • /
    • v.21 no.4 s.88
    • /
    • pp.545-555
    • /
    • 2005
  • The physicochemical and microbial characteristics of Oiji prepared with dry salting method, which has been used industrially for industry, were investigated. Low salting and low storage temperature were employed:extremely low salting extremely low temperature; ESET $(5\%,\;0^{\circ}C)$, very low salting extremely low temperature;VSET $(10\%,\;0^{\circ}C)$, extremely low salting very low temperature; ESVT$(5\%,\;5^{\circ}C)$, low salting very low temperature; VSVT$(10\%,\;5^{\circ}C)$ and high salting low temperature;HSLT$(30\%,\;10^{\circ}C)$ for control. Acidity was lower, and pH was higher in VSET, in of which the fermentation pattern was similar with that of HSLT The time required to reach the optimum acidity ($0.3\%$ lactic acid) was longer delayed for VSET (168 days), than for compared to ESVT (51 days). During storage of Oiji, greenness (-a) as measured with of the Hunter color system wasshowed the highest in VSET, and the lowest while in ESVT, the lowest. Total microbial and lactic acid bacteria counts number were the lowest in HSLT and VSET and were the lowest than in other groups, while the highest in ESVT. Yeast was not detected in HSLT, but was the highest while in VSVT. E coli coliform and listeria were detected in the $5\%$ salting groups, although Salmonella was not detected in any of the all groups. Texture profile analysis demonstrated exhibited that fracturability and hardness were highest in HSLT and VSET, compared to the other groups. Scores of over-all preference for ESVT and HSLT were higher atwith 6.3 and 6.2, respectively, compared to the other products. Based on these results, lower saltiness less than $10\%$ and lower storage temperature (less than $5^{\circ}C$) condition was optimum for maximizing the better for good quality of industrial Oiji preparation in industry.

Effects of Temperature in Anaerobic Nitrogen Removal Process from Piggery Waste : Activities in Ranges of Low Field-temperature (돈사폐수의 혐기성 질소제거에 있어서 온도의 영향 : 낮은 현장 온도범위에서의 활성)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.258-263
    • /
    • 2006
  • ANAMMOX (Anaerobic ammonium oxidation) reactor, which was cultivated ANAMMOX bacteria in mesophilic condition ($35^{\circ}C$), was operated to investigate the effects of temperature. In $20{\sim}30^{\circ}C$ of operation condition, which was assumed as field-temperature, total N removal and $NH_4-N$ removal rate were declined from about 2.50 and $1.27kg\;N/{m^3}_{reactor}-day$ (0.06 and 0.03 kg N/kgVSS/day) to 1.62 and $0.41kg\;N/{m^3}_{reactor}-day$ (0.04 and 0.01 kg N/kgVSS/day), In this range of temperature, ANAMMOX had very low activities but acid fermentation bacteria and denitrifiers, which were competitors of substrates, had high activities relatively. Though operation temperature was higher than inhibition condition for two months, ANAMMOX activities could not been recovered once they were inhibited by low temperature. This fact was resulted from very slow doubling time of ANAMMOX bacteria. This study shows that maintenance device of optimal temperature is necessary required in field application of ANAMMOX.