• 제목/요약/키워드: Vertical temperature difference

검색결과 261건 처리시간 0.033초

균열로의 그늘효과에 의한 슬랩변형에 관한 수치해석적 연구 (Numerical Study of Shadow Effect on Slab Deformation in Reheating Furnace)

  • 노정훈;황병복;맹주원;김재도
    • 소성∙가공
    • /
    • 제20권2호
    • /
    • pp.132-139
    • /
    • 2011
  • Three dimensional simulations were performed for the deformation of a slab in a roller hearth type slab reheating furnace. The main objective of this study was to examine the deformation pattern of the slab due to the shadow effect, i.e., the temperature difference between the upper and lower slab surfaces, in particular, the variations of displacement and effective stress in the vertical direction. A commercially available FE code, ANSYS Workbench $12.1^{TM}$, was used in a fully coupled thermo-elasticity analysis. Several cases with different slab surface temperatures were selected for the simulations. For the sake of simplicity, the temperature environment inside the furnace was assumed to be homogeneous for the upper and lower faces of the slab. Two cases of with different slab width were selected as model geometry. The deformation patterns were computed and explained in terms of periodicity and symmetry. The results indicated that the shadow effect leads to a significant displacement in the vertical direction and, thereby, is one of the main reasons for the separation of the slab and its supports. These simulations also predicted that the deformation is more severe along the transverse direction than along the longitudinal direction.

복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구 (A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

온돌난방공간(溫突暖房空間)의 내표면(內表面) 대류열전달특성(對流熱傳達特性)에 관(關)한 연구(硏究) (Convection Heat-Transfer Characteristics of Ondol-Heated Room)

  • 손장열;안병욱
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.376-385
    • /
    • 1991
  • The purpose of this paper is to propose basic data on convection heat-transfer coefficients in Ondol-heated room. Surface temperatures and several temperatures around each inside surface of wall, floor and ceiling composed of heating room are measured vertically in Ondol-heated model rooms, and the vertical temperature profiles could be expressed by nonlinear equation models. Also, the convection heat transfer phenomena are analysed from the nonlinear equation models. In the results, the convection heat-transfer coefficients of Ondol heated space are suggested by the term of temperature difference between each wall surface and room air temperature and by the relationship between Nusselt number and Rayleigh number of dimensionless numbers.

  • PDF

불안정 성층화를 가진 원통형 용기 내의 회전유동에 관한 연구 (Rotating Flows in a Circular Cylinder with Unstable Stratification)

  • 김재원
    • 한국전산유체공학회지
    • /
    • 제3권2호
    • /
    • pp.27-38
    • /
    • 1998
  • Rotating flow of a stratified fluid contained in a circular cylinder with unstable temperature gradient imposed on the side wall of it has been numerically studied. The temperatures at the endwall disks are constant. The top disk of the container is coider than that of the bottob disk, as much as the temperature difference n${\Delta}$T, (0${\leq}$n${\leq}$3). Flows in the vessel are driven by an impulsive rotation of the hot bottom disk with respect to the central axis of the cylinder. Flow details have been acquired. For this flow, the principal balance in the interior core is characterized by a relationship between the radial temperature gradient and the vertical shear in the azimuthal velocity. As the buoyancy effect becomes appreciable, larger portions of the meridional fluid transport are long-circuit from the bottom disk to the interior region via the side wall.

  • PDF

열영동력이 수평 웨이퍼상의 입자침착에 미치는 영향 (Thermophoretic Effect on Particle Deposition Toward a Horizontal Wafer)

  • 배귀남;박승오;이춘식
    • 대한기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.175-183
    • /
    • 1994
  • To investigate thermophoretic effect on particle deposition, average deposition velocity toward a horizontal wafer surface in vertical airflow is measured keeping the wafer surface temperature different from the surrounding air temperature. In the present measurement, the temperature difference is maintained in the range from -10 to $4^{\circ}$ C Polystyrene latex (PSL) spheres of diameter between 0.3 and 0.8 .mu.m are used for the experiment. The number of particles deposited on a wafer surface is estimated from the measurements using a wafer surface scanner (PMS SAS-3600). Experimental data are compared with prediction model results.

실내 기류의 수치해석 (Numerical method for Thermal Convection of air in Ondol Room)

  • 민만기;김주균
    • 대한설비공학회지:설비저널
    • /
    • 제7권1호
    • /
    • pp.4-12
    • /
    • 1978
  • At Grashof numbers $10^{10},\;5{\times}10^{10}$, and $10^{11}$ nonlinear partial differential equations for two dimensional thermal circulation of air in a rectangular enclosure heated from below are solved numerically by finite difference explicit methood in time-dependent form. Two vertical walls and ceiling are held at low temperature and floor at high temperture. Results are compared with From's numerical solutions at $10^9{\lesssim}\;N_{Gr}\;<10^{13}$. The effective draft temperature fields are also obtained to examine cold draft problem, there included a line of constant effective draft temperature $-1.667^{\circ}C$ which is essentially Houghten's $80\%$ comfort data.

  • PDF

Structural Characteristics of Turbulent Diffusion Flame Combusted with Simulated Coal Syngas

  • Park, Byung-Chul;Kim, Hyung-Taek;Chun, Won-Gee
    • 에너지공학
    • /
    • 제11권4호
    • /
    • pp.350-358
    • /
    • 2002
  • The present work determined the flame structure characteristics of coal syngas combusted inside swirl burners with various nozzle types. Fuel nozzle types are largely classified into two groups of axial and tangential. Experiments were carried out for investigating the effects of fuel nozzle geometry, fuel composition ratio, heating rate, excess air, and degree of swirl on the turbulent diffusion flame structure. To determine the characteristics of the flame structure, axial type fuel nozzle diameter of laboratory-scale combustor is varied to 1.23, 1.96, and 2.95 ㎜ and the direction of tangential type nozzles are varied to radial, clockwise, and counter-clockwise. The comparison of the experimental results was performed to understand functional parameters relating the flame structure. Data analysis showed that the vertical straight flame height generally decreased with increasing swirl number and decreasing axial type nozzle diameter. Flame height established with tangential type nozzle is 3 times shorter than that with vertical type. The flame structures among the 3 different tangential fuel nozzles relatively showed no particular difference. By increasing the heating rate, the width of flame increased generally in both vertical and tangential flame. Within the present experimental parameters of the investigation, flame structure is mainly depends on the nozzle type of the combustor. The visually investigated flame lengths are confirmed through the analysis of temperature profile of each flame.

타워 관측 자료를 이용한 연안 대기 경계층 내 바람 자원의 연직 변동 특성 (Characteristics of Vertical Variation of Wind Resources in Planetary Boundary Layer in Coastal Area using Tall Tower Observation)

  • 유정우;이화운;이순환;김동혁
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.632-643
    • /
    • 2012
  • Analysis of wind resources in Planetary Boundary Layer (PBL) using long term observation of tall tower located near coast line of the Korean Peninsula were carried out. The data observed at Pohang, Gunsan and Jinhae are wind, temperature and relative humidity with 10 minute interval for one year from 1 October 2010. Vertical turbulence intensity and its deviation at Pohang site is smaller than those of other sites, and momentum flux estimated at 6 vertical layers tend to show small difference in Pohang site in comparison with other sites. The change of friction velocity with atmospheric stability in Pohang is also not so great. These analysis indicate the mechanical forcing due to geographical element of upwind side is more predominant than thermal forcing. On the other hand, wind resources at Gunsan and Jinhae are mainly controlled by thermal forcing.

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

Enhancement of Absorption Performance Due to the Wavy Film of the Vertical Absorber Tube

  • Kim Jung-Kuk;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.41-48
    • /
    • 2006
  • Absorption performance at the vertical interface between refrigerant vapor and liquid solution of $LiBr-H_{2}O$ solution was enhanced by the waves formed due to the interfacial shear stress. The present study investigated experimentally and analytically the improvements of absorption performance in a falling film by wavy film flow. The dynamic parameter was the film Reynolds numbers ranged from 50 to 150. The energy and diffusion equations were solved simultaneously to find the temperature and concentration profiles at the interface of liquid solution and refrigerant vapor. Absorption characteristics due to heat and mass transfer were analyzed for the falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Absorption performance showed a peak value at the solution flow rate of $Re_{f}>100$. Absorption performance for the wavy film flow was found to be greater by approximately 10% than that for uniform film flow. Based on numerical and experimental results, the maximum absorption rate was obtained for the wavy flow caused by spring insert. The difference between the measured and the predicted results were ranged from 5.8 to 12%.