연직관측자료를 통한 복잡 연안지역의 오존 이류특성 (Characteristics of Ozone Advection in Vertical Observation Analysis Around Complex Coastal Area)

  • 이화운;박순영;이순환;임헌호
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.57-74
    • /
    • 2009
  • In order to clarify the vertical ozone distribution in planetary boundary layer of coastal area with complex terrain, an observation campaign was carried out around Gwangyang Bay with dense pollutant emission sources during two days from June, 4 2007. For this observation are Radiosonde, SODAR(SOnic Detection And Ranging) and Tethered ozone sonde were employed. The surface meteorological and photochemical observation data provided by AWS (Automatic Weather System) and AQMS (Air Quality Monitoring System) were also applied for analysis. Synoptic condition is strongly associated with lower level ozone distribution in complex terrain coastal area. Since mesoscale circulation induced by difference of characteristics of land and sea and orographic forcing is predominant under calm synoptic condition, vertical distribution of ozone is complicate and vertical ozone concentration greatly fluctuated. However in second day when synoptic influence become strong, ozone concentration in lower levels is vertically uniform regardless of observation level. This results in vertical observation indicates that vertical ozone distribution is often determined by synoptic condition and also affects surface ozone concentration.

부산연안역의 대기경계층내 잔류 오존의 연직하향혼합에 의한 지표 오존농도의 변화 특성 (Variations of Surface Ozone Concentration by Vertical Downward Mixing of Ozone in the Residual Layer of the Atmospheric Boundary Layer at the Busan Coastal Area)

  • 전병일
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.417-422
    • /
    • 2001
  • The vertical structure of atmosphere was observed In investigate the variation of surface ozone concentration by vertical downward mixing of residual ozone in the atmospheric boundary layer at the Busan coastal area. Airsonde and pilot balloon measurements were made at Gamcheondong and the Kimhae airport for April 26~27, 1996. The vertical potential of potential temperature showed a residual layer between 510m and 1800m from 2100LST April 26 to 0900LST April 27. The downward mixing of ozone in the residual layer of the atmospheric boundary layer was confirmed from vertical profile of mixing ratio near 600m in the morning. The thickness of the sea breeze layer was 900m at 1500LST April 26. Thereafter, it become to be lowered with time A low level jet was measured near 900m at 0300LST on April 27 from a pibal measurement. Early morning sharp increase of surface ozone concentration at the Busan coastal area was caused by vertical downward mixing of ozone concentration rather than by photochemical reaction In the atmospheric boundary layer.

  • PDF

2차원 광화학수송모델을 이용한 포항지역의 1995-1996년 기간동안 오존의 연직 프로파일 및 전량 추정 (Estimation of Vertical Profiles and Total Amount of Ozone Using Two-Dimensional Photochemical Transfer Model During the Period of 1995-1996 at Pohang)

  • 문윤섭
    • 한국대기환경학회지
    • /
    • 제22권3호
    • /
    • pp.271-285
    • /
    • 2006
  • A two-dimensional photochemical transport model (2D PTM) is simulated to describe the transport and chemical reaction of ozone related to aerosols in the troposphere and stratosphere. The vertical profiles and total amounts of ozone, which are advected by both residual Eulerian circulation and the adiabatic circulation under certain circumstance, have been compared with the observation data such as ozonesondes, Brewer spectrometer, the Upper Atmosphere Research Satellite (UARS), and the Total Ozone Mapping Spectrophotometer (TOMS). As a result, we find that the observed distribution of ozone Is adequately reproduced in the model at middle and high latitude in the Northern Hemisphere as well as at Phang ($36^{\circ}\;02'N,\;129^{\circ}\;23'E$) in South Korea. In particular, the 2D PTM is well simulated in the ozone decrease due to the Pinatubo volcanic eruption in 1991. However, ozone mixing ratio are more underestimated than those of UARS and ozonesondes, because are very sensitive to the latitude of transport across the tropopause associated with both Rummukainen errors and off-line model. Relative mean bias errors and relative root mean square errors of ozone calculations using the 2D PTM are shown within${\pm}10%$, respectively.

MERRA-2 재분석자료를 활용한 적도 대류권계면층의 오존 수송 및 계절변동성 분석 (Analysis of the Ozone Transport and Seasonal Variability in the Tropical Tropopause Layer using MERRA-2 Reanalysis Data)

  • 류호선;김주완
    • 대기
    • /
    • 제30권1호
    • /
    • pp.91-102
    • /
    • 2020
  • MERRA-2 ozone and atmospheric data are utilized to test the usefulness of reanalysis-based tracer transport analysis for ozone in the tropical tropopause layer (TTL). Transport and mixing processes related to the seasonal variation of TTL ozone are examined using the tracer transport equation based on the transformed Eulerian mean, and the results are compared to previously proposed values from model analyses. The analysis shows that the seasonal variability of TTL ozone is mainly determined by two processes: vertical mean transport and horizontal eddy mixing of ozone, with different contributions in the Northern and Southern Hemispheres. The horizontal eddy mixing process explains the major portion of the seasonal cycle in the northern TTL, while the vertical mean transport dominates in the southern TTL. The Asian summer monsoon likely contributes to this observed difference. The ozone variability and related processes in MERRA-2 reanalysis show qualitatively similar features with satellite- and model-based analyses, and it provides advantages of fine-scale analyses. However, it still shows significant quantitative biases in ozone budget analysis.

The origin and seasonal characteristics of tropospheric ozone observed over Pohang, Korea

  • Kim, Jae-Hwan;Lee, Hyun-Jin
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.59-60
    • /
    • 2003
  • In this study, we present the analysis of vertical ozone sounding data observed over Pohang, Korea, and investigate to understand the governing mechanisms for seasonal ozone maximum in June. The vertical ozone profiles in June show that the ozone enhancement is clearly shown in the middle and upper troposphere. We have found that the June maximum is associated with the transport of ozone rich air from the stratosphere and polluted continental air mass. This is different from the previous studies shown that the regionally polluted continental air mass, influenced by the intense anthropogenic activities m northeast Asia during transport, is responsible for the ozone maximum in spring.

  • PDF

기단성 뇌우 발생시 지표오존농도의 변화 특성 (Characteristics of the surface ozone concentration on the occurrence of air mass thunderstorm)

  • 전병일
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.419-426
    • /
    • 2003
  • This study was performed to research ozone concentration related to airmass thunderstorm using 12 years meteorological data(1990~2001) at Busan. The occurrence frequency of thunderstorm during 12 years was 156 days(annual mean 13days). The airmass thunderstorm frequency was 14 days, most of those occurrence at summertime(59%). In case August 4, 1996, increase of ozone concentration was simultaneous with the decrease of temperature and increase of relative humidity, In case July 23, 1997, ozone concentration of western site at Busan increased, while its of eastern site decreased as airmass thunderstorm occurred(about 1500LST). It is supposed that these ozone increases are the effect of ozone rich air that is brought down by cumulus downdrafts from height levels where the ozone mixing ratio is larger. Thunderstorms can cause downward transport of ozone from the reservoir layer in the upper troposphere into planeta교 boundary layer(PBL). This complex interaction of source and sink processes can result in large variability fer vertical and horizontal ozone distributions. Thus a variety of meteorological precesses can act to enhance vertical mixing between the earth's surface and the atmospheric in the manner described fer thunderstorm.

GMAP 2021 캠페인 기간 용인지역 오존 연직 분포 관측 (The Observation of Ozone Vertical Profile in Yongin, Korea During the GMAP 2021 Field Campaign)

  • 류호선;구자호;김형규;이나현;이원진;김주완
    • 대기
    • /
    • 제32권3호
    • /
    • pp.247-261
    • /
    • 2022
  • The importance of ozone monitoring has been growing due to the polar ozone depletion and increasing tropospheric ozone concentration over many Asian countries, including South Korea. In-situ measurement of the vertical ozone structure has advantages for ozone research, but observations are not sufficient. In this study, ozonesonde measurements were performed from October to November in Yongin during the GMAP (The GEMS Map of Air Pollution) 2021 campaign. The procedure for ozonesonde preparation and initial analysis of the observed ozone profile are documented. The observed ozone concentrations are in good agreement with previous studies in the troposphere, and they capture the stratospheric ozone distribution as well, including stratosphere-troposphere exchange event. These balloon-borne in situ measurements can contribute to the evaluation of remote sensing measurements such as Geostationary Environment Monitoring Spectrometer (GEMS). This document focuses on providing essential information of ozonesonde preparation and measurement for domestic researchers.

Influence of Stratospheric Intrusion on Upper Tropospheric Ozone over the Tropical North Atlantic

  • Kim, So-Myoung;Na, Sun-Mi;Kim, Jae-Hwan
    • 한국지구과학회지
    • /
    • 제29권5호
    • /
    • pp.428-436
    • /
    • 2008
  • This study observed the upper tropospheric ozone enhancement in the northern Atlantic for the Aerosols99 campaign in January-February 1999. To find the origin of this air, we have analyzed the horizontal and vertical fields of Isentropic Potential Vorticity (IPV) and Relative Humidity (RH). The arch-shaped IPV is greater than 1.5 pvus indicating stratospheric air stretches equatorward. These arch-shaped regions are connected with regions of RH less than 20%. The vertical fields of IPV and RH show the folding layer penetrating into the upper troposphere. These features support the idea that the upper tropospheric ozone enhancement originated from the stratosphere. Additionally, we have investigated the climatological frequency of stratospheric intrusion over the tropical north Atlantic using IPV and RH. The total frequency between the equator and $30^{\circ}N$ over the tropical north Atlantic exhibits a maximum in northern winter. It suggests that the stratospheric intrusion plays an important role in enhancing ozone in the upper troposphere over the tropical north Atlantic in winter and early spring. Although the tropospheric ozone residual method assumed zonally invariant stratospheric ozone, stratospheric zonal ozone variance could be caused by stratospheric intrusions. This implies that stratospheric intrusion influences ozone variance over the Atlantic in boreal winter and spring, and the intrusion is a possible source for the tropical north Atlantic paradox.

The Role of Fronts on the Vertical Transport of Atmospheric Pollutants (2-D model)

  • Nam, Jae-Cheol
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.65-68
    • /
    • 2003
  • A quantitative study of the amount of air transported between the boundary layer and the free atmosphere is important for understanding air quality and upper tropospheric ozone, which is a greenhouse gas. Frontal systems are known to be an effective mechanism for the vertical transport of pollutants. Numerical experiments have been performed with a simple two-dimensional front model to simulate vertical transport of trace gases within developing cold fronts. Three different trace gases experiments have been done numerically according to the different initial fields of trace gases such as aerosol, ozone and $H_2O_2$. Trace gas field tilts to the east while the front tilts to the west. Aerosol simulation shows that pollutants can be transported out of the boundary to altitudes of about 10 km. The stratospheric ozone is brought downwards in a tropopause fold behind of the frontal surface. The meridional gradient in trace gas ($H_2O_2$) can cause a complicate structure in the trace field by the meridional advection.

  • PDF

태양 엄폐법에 의한 연직 오존 분포 도출과 민감도 실험 (RETRIEVAL OF VERTICAL OZONE PROFILE USING SATELLITE SOLAR OCCULTATION METHOD AND TESTS OF ITS SCNSITIVITY)

  • 조희구;윤영준;박재형;이광목;요코다타쓰야
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권1호
    • /
    • pp.119-138
    • /
    • 1998
  • 최근에 인공위성에 의한 대기 중의 미량 기체 관측이 활발하다. 따라서 이들 자료의 처리기법 개발이 매우 중요하다. 그러므로 이 연구에서는 인공위성에 의해 태양 엄폐범(太陽 掩蔽法: Solar Occultation Method)으로 관측한 대기 주연 경로(周緣 經路: limb path)의 접선 고도별 평균 투과율로부터 연직 오존 분포를 도출하고, 온도와 기압 오차의 민감도 오차의 민감도 실험을 하고자 한다. 여기에서 서울의 반전(Umkehr)관측에 의하여 구한 연평균 연직 오존분포로 계산된 평균 투과율을 인공위성으로부터 관측된 평균 투과율로 가정하였다. HALOE SIDS (Hallogen Occultation Experiment Simulated Instrument Data Set)의 연직 오존 자료를 초기치로 하고 온도와 기압의 연직 분포를 입력값으로 하여 대기 평균 투과율을 파장 $9.89{\mu}m$$10.02{\mu}m$ 사이에서 접선고도별로 계산했다. 관측 평균 투과율에 대하여 계산한 평균 투과율로부터 오존 분포 법으로 접선고도 10km에서 50km까지 매 3km마다 오존 농도를 도출하였다. 도출된 서울의 연직 오존 분포를 관측한 연직 오존 분포와 비교하였다. 이 결과에 의하면 전 고도에 걸쳐서 서울의 연직 오존 분포가 오차가 거의 없을 정도로 정확하게 도출되었다. 그리고 민감도 실험을 위하여 관측 평균 투과율에$\pm0.001$, 각 층의 온도에 $\pm3K$, 그리고 각 층에 기압의 $\pm3\%$의 강제 오차를 각각 주었다. 이들 각 오차는 ADEOS/ILAS 관측 오차에 근거하였다. 이들의 결과는 투과율 오차에 대하여 -6.5%에서 +6.9%, 온도 오차에 대하여 -9.5%에서 +10.5, 그리고 기압 오차에 대하여 -5.1%에서 +5.4%의 고도별 오존 량 오차가 각각 나타났다. 태양 엄폐 법에 의해 비교적 정확한 연직 오존 분포를 도출할 수 있었다. 이 도출 과정에서 특히 온도 관측이 중요함을 알 수 있었다.

  • PDF