• Title/Summary/Keyword: Vertical closed loop

Search Result 60, Processing Time 0.028 seconds

Strapdown Attitude Reference System(SARS) in the Railway and Aviation System using Fuzzy Inference (퍼지추론을 이용한 철도.항공시스템에서의 자세제어시스템)

  • Kim, Min-Soo;Byun, Yeun-Sub;Lee, Kwan-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2077-2078
    • /
    • 2006
  • This paper describes the development or a closed-loop Strapdown Attitude Reference System (SARS) algorithm integrated filtering estimator for determining attitude reference for railway and aviation system using fuzzy inference. The SARS consists of 3 single-axis rate gyms in conjunction with 2 single-axis accelerometers. For optimal values of fuzzy systems, we utilize on-line scheduling method for initial values and then use genetic algorithms for fine tuning. Implementation using experimental test data of unmanned aerial vehicle has been performed in order to verify the estimation. The proposed fuzzy inference based SARS demonstrate that more accurate performance can be achieved in comparison with conventional one. The estimation results were compared with the on-board vertical gyro as the reference standard.

  • PDF

Recognition and classification of dimension set for automatic input of mechanical drawings (기계 도면의 자동 입력을 위한 치수 집합의 인식 및 분류)

  • 정윤수;박길흠
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.114-125
    • /
    • 1997
  • This paper presents a method that automatically recognizes dimension sets from the mechanical drawings, and that classifies 6 types dimension sets according to functional purpose. In the proposed method, the object and closed-loop symbols are separated from the character-free drawings. Then object lines and interpretation lines are vectorized. And, after recognizing dimension sets(consistings of arrowhead, shape line, tail lines, extension lines, text-string, and feature control frame), we classify recognized dimension sets as horizontal, vertical, angular, diametral, radial, and leader dimension sets. Finally the proposed method converts classified dimension sets into AutoCAD data by using AutoLisp language. By using the methods of geometric modeling, the proposed method readily recognized and classifies dimension sets from complex drawings. Experimetnal results are presented, which are obtained by applying the proposed method to drawings drawn in compliance with the KS drafting standard.

  • PDF

Design and Tracking Control of 4-DOF Motion Platform for Bicycle Simulator (자전거 시뮬레이터용 4자유도 운동판의 설계 및 추적 제어)

  • 성지원;신재철;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.235-240
    • /
    • 2001
  • A four degrees of freedom (dof) motion platform for bicycle simulator is developed. The motion platform, capable of the vertical linear and three angular motions, is designed based on analysis of the typical motion characteristics revealed by the existing six dof bicycle simulator. The platform essentially consists of two parts: the three dof parallel manipulator, consisting of a moving platform, a fixed base and three actuators, and the turntable to generate the yaw motion. The nonlinear kinematics and dynamics of the three dof parallel manipulator with multiple closed loop chains are analyzed for tracking control of the motion platform. The tracking performances of the three control schemes are experimentally compared: the computed torque method (CTM), the sliding mode control (SMC) and the PD control. The CTM and SMC, incorporated with the system dynamics model, are found to be equally better in performance than the PD controller, irrespective of the presence of external disturbance.

  • PDF

A Basic Study of the Snow Melting System for the Anti-Freezing Road using the Pulsating Heat Pipe (PHP를 이용한 도로융설 시스템에 관한 기초연구)

  • Kim, J.S.;Ha, S.J.;Son, K.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.19-24
    • /
    • 2010
  • The purpose of this study is to develop a snow melting system using the pulsating heat pipe(PHP). The experimental apparatus is consisted of a PHP, a concrete structure, a constant water thermostatic bath and a flowmeter. The experiment was performed at the outdoor air temperature of $-8^{\circ}C$ and inlet temperature of hot water of $75^{\circ}C$. PHP is the closed and non-loop type heat exchanger which is charging R-410A as an operating fluid. As experimental results, the temperature profile of vertical and horizontal orientation of concrete structure was measured with operating time. The heat flux of the snow melting was required more than 300 $W/m^2$. We confirmed that the snow melting system using the PHP was useful for anti-freezing road.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.

Giant Neurofibroma on Both Buttocks (양측 엉덩이의 거대 신경섬유종)

  • Kim, Ji Hoon;Burm, Jin Sik;Kim, Yang Woo;Kang, So Ra;Kim, Hyoung Kyoung
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.512-515
    • /
    • 2009
  • Purpose: Neurofibromatosis(NF) is an autosomal - dominant systemic disease. Up to fifty percent of patients with NF are reported to have concomitant vascular abnormalities. In the resection of a larger NF, the risk of uncontrolled hemorrhage is much higher due to the difficulty of hemostasis of large vessels within the tumor. We ligated the base of the giant NF with a simple loop - shaped ligation before removal of the giant NF in both buttocks. And then we could successfully reduce the amount of hemorrhage during the operation. Methods: A 46 - year - old female patient presented for giant masses of both gluteal area, which has been growing slowly for the last ten years. Each mass was about $30{\times}20cm$ in size. After designing the elliptical resection margin, we tightened the tumor base by using continuous loop - shaped suture ligation(weaving the thread up and down in a loop - shaped pattern, leaving a space of 2 cm between each loop) with a straight needle and prolene 2 - 0. After skin incision, we proceeded the dissection toward the central and inferior side of the mass obliquely while we avoided breaking large vascular sinuses. We resected the tumor in a wedged - shape. Subcutaneous tissue was sutured layer by layer and skin was closed by vertical mattress and interrupted suture. The loop - shaped ligation of the base was removed and compressive dressing was done with gauzes and elastic bandages. Results: Postoperative complications such as infection, hemorrhage, hematoma, and dehiscense did not occur. Perioperatively the patient was sufficiently transfused with five units of blood and two units of fresh frozen plasma. During the subsequent 1 year follow - up, the functional and cosmetic result was excellent. Conclusion: A continuous loop - shaped suture ligation procedure along the base of the giant NF effectively reduced the amount of hemorrhage during the operation, made dissection and ligation of vessels easily and quickly, and shorten the operating time and postoperative recovery time.

Thermal conductivity and viscosity of graphite-added bentonite grout for backfilling ground heat exchanger (지중 열교환기용 뒤채움재로서 흑연을 첨가한 벤토나이트 그라우트재의 열전도도 및 점도 특성)

  • Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok;Choi, Hyo-Pum
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Bentonite-based grouting has been usually used for sealing a borehole installed for a closed-loop vertical ground heat exchanger in a geothermal heat pump system (GHP) because of its high swelling potential and low hydraulic conductivity. The bentonite-based grout, however, has relatively lower thermal conductivity than that of ground formation. Accordingly, it is common to add some additives such as silica sand into the bentonite-based grout for enhancing heat transfer. In this study, graphite is adapted to substitute silica sand as an addictive because graphite has very high thermal conductivity. The effect of graphite on the thermal conductivity of bentonite-based grouts has been quantitatively evaluated for seven bentonite grouts from different product sources. In addition, the viscosity of graphite-added bentonite grout was measured to evaluate the field pumpability of the grout.

  • PDF

Study on cement-based grout for closed-loop vertical ground heat exchanger (수직 밀폐형 지중 열교환기 뒤채움재로서 시멘트 그라우트의 적용성 검토)

  • Park, Moon-Seo;Wi, Ji-Hae;Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.615-624
    • /
    • 2010
  • In this paper, the applicability of cement grout has been studied as an alternative to bentontite grout to backfill ground heat exchangers. To provide an optimal mixture design, the groutabilty and thermal conductivity of cement grouts with various mixture ratios were experimentally evaluated and compared. The unconfined compression strength of cement grout specimen was measured, which are exposed to cyclic temperature variation ranging from $50^{\circ}C$ to $-5^{\circ}C$. In addition, the integrity of the interface between circulating HDPE pipes and cement grout by performing equivalent hydraulic conductivity tests, in which a pipe locates at the center of the specimen.

  • PDF

The Characteristics of Thermal Diffusion With the Vertical-Closed Loop Type Geothermal Heat Exchanger (수직밀폐형 지중열교환기의 온도분포 특성)

  • Sun, Jong-Cheol;Kim, Byung-Chul;Koh, Young-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.57-65
    • /
    • 2013
  • The temperatures with the ground depth, the positions of circulation water in ground heat exchanger were measured and thermal diffusion characteristics with the distances of the direction normal to the borehole was analysed. The deeper the depth of ground, the less the influences of outdoor temperature, but below 10m of ground, there was no influences of ground temperature. When the depth of trench pipe was below the depth of 2m, there was no influence. In the ground of 10m when the distances between the pipe and the other places were above 0.5m, the variations of temperature were less than $1.6^{\circ}C$ and above 2.5m they were less than $0.1^{\circ}C$. When the distances of bore hole were above 5m, there were no. influences of the nearest ground heat exchanger.

Feasibility of a new hybrid base isolation system consisting of MR elastomer and roller bearing

  • Hwang, Yongmoon;Lee, Chan Woo;Lee, Junghoon;Jung, Hyung-Jo
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.323-335
    • /
    • 2020
  • Magnetorheological elastomer (MRE), a smart material, is an innovative material for base isolation system. It has magnetorheological (MR) effect that can control the stiffness in real-time. In this paper, a new hybrid base isolation system combining two electromagnetic closed circuits and the roller bearing is proposed. In the proposed system, the roller part can support the vertical load. Thus, the MRE part is free from the vertical load and can exhibit the maximum MR effect. The MRE magnetic loop is constructed in the free space of the roller bearing and forms a strong magnetic field. To demonstrate the performance of the proposed hybrid base isolation system, dynamic characteristic tests and performance evaluation were carried out. Dynamic characteristic tests were performed under the extensive range of strain of the MRE and the change of the applied current. Performance evaluation was carried out using the hybrid simulation under five earthquakes (i.e., El Centro, Kobe, Hachinohe, Northridge, and Loma Prieta). Especially, semi-active fuzzy control algorithm was applied and compared with passive type. From the performance evaluation, the comparison shows that the new hybrid base isolation system using fuzzy control algorithm is superior to passive type in reducing the acceleration and displacement responses of a target structure.