• Title/Summary/Keyword: Vertical Vibration Level

Search Result 101, Processing Time 0.029 seconds

A study on vibration characteristics of track components according to track type in HSL tunnel (고속선 터널내 궤도 형식에 따른 궤도 구성품의 진동 특성에 관한 연구)

  • Kim Man-Cheol;Jang Seung-Yup;Kang Yun-Suk;Han Jin-Seok;Han Sang-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.498-503
    • /
    • 2005
  • In this paper, an experimental study is carried out to analyze the vibration characteristics of components of the ballast track and the slab track layed in HSL tunnels. According to vibration level test of ballast tracks and concrete tracks on HSL, the vertical vibration level of rails on concrete tracks is 6.2dB more than that on ballast tracks, and especially on $50{\sim}80Hz$ frequency band, the difference is more than 6dB. The orther track components according to track type are appeared to be smaller on the slab track than on the ballast track. Regarding car body vibration, 80Hz component, which was not remarkable while running on open tracks, is considerably amplified in tunnels where concrete tracks are laid.

  • PDF

The Effects of the Wave Propagation Path of Ground Vibration Induced by the Subway Train on the Reduction of Vibration Level (지하철 주변 지반진동의 전파경로가 진동레벨 감쇠에 미치는 영향)

  • Shin, Han-Chul;Cho, Sun-Kyu;Yang, Shin-Chu;Lee, Jong-Min
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.631-640
    • /
    • 2009
  • In this paper, Numerical analysis was conducted to study on the reduction of ground vibration level induced by subway train. The analytical results indicated that the soil properties were the predominant factor affecting the ground vibration when the tunnel was located in the soil layer. On the other hand, the rock properties were the predominant one when the tunnel was located in the rock layer. The effects of the angle between the vertical line of vibration source and the receive point on the reduction of vibration level were also evaluated. There were little difference in the reduction of vibration level when the receive point was located within $30^{\circ}$. The vibration level, however, rapidly decreased when the angle between the two points was larger than $40^{\circ}$.

Active Control of Vibrational Intensity at a Reference Point in an Infinite, Elastic Plate (무한 탄성 평판상의 기준점에 전달되는 진동인텐시티의 능동제어)

  • 김기만
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper, active control of vibrational intensity at a reference point in an infinite, elastic plate was discussed. The plate is excised harmonically by a vibrating source, which has a vertical point force. The optimal condition of controller was investigated to minimize the vibrational intensity being transmitted from the vibrating source to a reference point. Hence the method of feedforward control was employed for the control strategy and then the cost function was evaluated to find the optimal control force. Three types of control force (Vertical force, Moment, and Coupling force (a set of vertical force and moment) ) and controller's positions were examined to define the optimal condition of the controller. The vibrational intensity at a reference point was found to be reduced down to a zero level, compared with the uncontrolled case. Especially maximum reduction of vibrational intensity was achieved when the controller was collinearly positioned between a vibrating source and a reference point.

  • PDF

A Study on the Vertical SPL of Railway Noise by Noise Barrier (방음벽 설치에 따른 철도소음의 수직음압레벨 분포특성에 관한 연구)

  • 윤해동;윤희경;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1099-1103
    • /
    • 2002
  • With rapidly industrial development, a railway has become of a main traffic means. But, the railway noise has caused much annoyance for the residents living nearby railway tracks. Therefore, in our country, for established of quite dwelling environment. execute regulation standard of railway noise from January 1. 2000. Efficiency soundproofing measures, however, are very difficult because of the lack of basic data and insufficiency of the existing research. In this point. this study attempts to survey the vertical sound pressure level of railway noise in by existence of noise harrier And this study intends to get the basic data for establishment of a efficient noise barrier about railway noise.

  • PDF

Serviceability Performance Evaluation of Vertical Vibration of Waflle Shape and Duble-Tee Precast Concrete Slabs (와플형과 더블티형 프리캐스트 콘크리트 바닥판의 수직진동 사용성 평가)

  • Shin, Jae-Sang;Chung, Lan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.62-69
    • /
    • 2010
  • In this study, the serviceability performance of Waffle Shaped(WAS) and Double-Tee(DT) precast concrete slabs were evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan) and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and Peak acceleration level of WA slabs was lower than that of DT slabs.

Structure Dynamic Analysis of 6kW Class Vertical-Axis Wind Turbine with Tower (타워를 포함한 6kW급 수직축 풍력발전기 구조진동해석)

  • Kim, Dong-Hyun;Ryu, Gyeong-Joong;Kim, Yo-Han;Kim, Sung-Bok;Kim, Kwang-Won;Nam, Hyo-Woo;Lee, Myoung-Goo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.663-670
    • /
    • 2011
  • In this study, the design and verification of 6kW class lift-type vertical-axis wind turbine (VAWT) has been conducted using advanced CAE technique based on computational fluid dynamics (CFD), finite element method (FEM), and computational structural dynamics (CSD). Designed aerodynamic performance of the VAWT model is tested using unsteady CFD method. Designed structural safety is also tested through the evaluation of maximum induced stress level and resonance characteristics using FEM and CSD methods. It is importantly shown that the effect of master eccentricity due to rotational inertia needs to be carefully considered to additionally investigate dynamic stress and deformation level of the designed VAWT system.

  • PDF

A Study on the Effect of Changes in Chevron Rubber Characteristics on the Vibrational Ride Comfort Level of a Subway Vehicle (도시철도차량 세브론 고무 특성 변화가 진동승차감 레벨에 미치는 영향 연구)

  • Park, Nam Cheol;Koo, Jeong Seo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 2016
  • The suspension system of a subway vehicle is composed of $1^{st}$ and $2^{nd}$ springs. The suspension system is the most important parameter in determining the vibration ride comfort. If the $1^{st}$ suspension spring is designed as a spring with strong stiffness to improve the running stability at high speed, it causes vehicle vibrations. In this paper, by testing and analyzing changes of the characteristics of Chevron springs, which have been the primary suspension springs used for about 20 years, we study how changing the characteristics affects vehicle acceleration and ride comfort. The lateral and longitudinal vibrational ride comfort index levels were lower than the vertical ones. Therefore, as increasing the stiffness of Chevron springs has the greatest effect on the vertical vibrational ride comfort index level, a countermeasure for vertical vibration reduction is needed when the stiffness increases owing to aging. Finally, maintenance guidelines, including the replacement time for the Chevron rubber, were proposed based on these findings.

Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea (한국고속철도 천안역사에 대한 소음 및 진동영향 연구)

  • Kweon Young-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

Optimum Transport Systems of Agricultural Products(II) -Vibration characteristics of the transporting traliler- (농산물 수송 최적화 시스템 (II) -트레일러의 진동 분포 특성-)

  • 홍종호;이홍주
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.315-322
    • /
    • 2001
  • Agricultural products can be damaged due to the vibration of transporting trailer on the off-road. So, this study was conducted to identify the vibration characteristics of the agricultural products transporting trailer by measuring the vertical acceleration according to positions on the trailer loaded with agricultural products. The results of this study can be summarized as follows: 1. At non-operating state of engine, the larger vertical acceleration was occurred at rear side compared with front side in the case of 4.5Hz of vibration frequency. But, in the case of 53.5Hz of frequency, the maximum vertical acceleration at front side of trailer was higher than value at rear side. So, the maximum acceleration at front side of the trailer was increased with the increase in frequency. 2. At operating state of engine, the maximum vertical acceleration at front side of the trailer was increased with the increase in frequency. 2 At operating state of engine, the maximum vertical acceleration delivered through the hitch from the engine was occurred at front side of the trailer as $3.0\times10^{-3}m/s^2$, in the case of 8.75Hz of frequency. But, in the case of 102.5Hz of high frequency, the maximum vertical acceleration was occurred at rear side of the trailer. 3. When the power tiller loaded with pear of 325kg was travelling on the artificial uneven road of 3cm height, the maximum acceleration was occurred at rear side of the trailer as $4.7\times10^{-3}m/s^2$at 3.75Hz of frequency. But, that was occurred at diagonal of the trailer 43.5Hz and 91.25Hz, which meant that there was rolling and pitching on the trailer. 4. At operating state of engine, the mean acceleration of the trailer delivered through the hitch according to the increase in frequencies was showed the maximum value at range of 40-90Hz. At rear side of traiㅣer, the maximum value was occurred at about 40Hz, and that was reduced according to the increase in frequencies and diminished at about 100Hz. 5. When the power tiller loaded with pear of 32.5kg was travelling on the artificial uneven road of 3cm height, the mean acceleration by the increase in frequencies was showed lower level at rear side than front side of the trailer. This was opposite configuration to the Hinsch’s results tested with air-conditioned truck. This means that the shorter length of the trailer, the more effect of engine vibration is transferred to the front side of trailer.

  • PDF

Study on Interior Noise Transfer Path Analysis by Tire Cavity Resonance (타이어 공동의 공명에 의한 차량 실내음 전달경로 연구)

  • Lee, Sang-Ju;Kang, Byun-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.129-133
    • /
    • 2005
  • Vibration transmitted through rolling tire is a major source of road noise in vehicle interior noise on the range of low frequency.($0{\sim}500Hz$) Among various road noises, tire cavity noise has very peak on $200{\sim}250Hz$. And generally it is generated by cavity resonance of tire. In this paper, tire cut-sample is used to calculate the tire cavity frequency. Cavity resonance frequency of tire is measured through vertical/tangential forces at load cell of axle using drum cleat impact. This method is useful to find cavity peak because measured forces do not have complex peaks. And changing the test conditions (air inflation, loads), tire cavity resonance characteristics are identified. Finally, vehicle interior noise is measured as tire/vehicle are changing. As difference of tire vertical force is bigger, interior noise level is higher at cavity frequency. Also we can assume that vehicle sensitivity is important factor at tire cavity noise.

  • PDF