• 제목/요약/키워드: Vertical Pump

검색결과 195건 처리시간 0.024초

지중 유효 열물성 산정 및 지중열교환기 성능에 대한 보어홀 열저항의 영향 (Evaluation of Ground Effective Thermal Properties and Effect of Borehole Thermal Resistance on Performance of Ground Heat Exchanger)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.32-40
    • /
    • 2012
  • Geothermal heat pump(GHP) systems use vertical borehole heat exchangers to transfer heat to and from the surrounding ground via a heat carrier fluid that circulates between the borehole and the heat pump. An Important feature associated with design parameters and system performance is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. This paper deals with the in-situ experimental determination of the effective thermal properties of the ground. The recorded thermal responses together with the line-source theory are used to determine the thermal conductivity and thermal diffusivity, and the steady-state borehole thermal resistance. In addition, this paper compares the experimental borehole resistance with the results from the different empirical and theoretical relations to evaluate this resistance. Further, the performance simulation of a GHP system with vertical borehole heat exchangers was conducted to analyze the effect of the borehole thermal resistance on the system performance.

액체로켓 추진기관의 후류처리장치 고찰 (Investigation of Exhaust Facility of Liquid Rocket Propulsion System)

  • 조남경;이광진;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.133-138
    • /
    • 2012
  • 후류처리 장치는 기본적으로 화염유도로의 역할을 하며 추가적인 기능에 따라 소음/배기가스 처리 장치, 고공 모사 장치 등으로 분류될 수 있다. 본 연구에서는 화염 및 충격파로 부터의 발사체 보호, 제트펌프, 유해배기 가스 저감 등 후류처리 장치에 적용되는 원리를 제시하였다. 물 분사에 의한 소음감소는 마하파를 약화시키며 물의 증발 및 응축을 통해 제트의 에너지를 줄이는 원리를 이용함을 보였다. 또한 후류처리 장치에 적용되는 원리의 고찰을 통하여 수직형 후류처리 장치의 개념을 제시하였다.

  • PDF

수위변화에 따른 수직형 펌프의 진동 발생 사례 고찰 (A Case Study on Vibration of Vertical Pumps according to Changing Water Level)

  • 송애희;송진대;김현식;정기철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.274-278
    • /
    • 2012
  • Vertical pumps are structurally weak in terms of vibration because of installed heavy motor on top of the pumps in form of cantilever. So high vibration on top of the pumps can occur with low vibration in the bottom. These vibration problems experienced very frequently. Majority of studies have been related to the unbalance of rotating parts or structural resonance. In this paper, we introduce an unusual case, vibration variation caused by VPF(Vane Passing Frequency) according to water level.

  • PDF

수직벽 후방박리영역 감소를 위한 맥동제트의 최적화 연구 (Optimization study of pulsating jet for reducing the separation bubble behind the vertical fence)

  • 최영호;강인수;김형범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.185-188
    • /
    • 2008
  • In this study, we experimentally investigated that the optimization of pulsating jet to reduce the separated flow region behind the vertical fence. The vertical fence was submerged in the turbulent boundary layer in the circulating water channel and we applied phase averaged PIV method to measure the instantaneous velocity fields around the fence. One cycle of pulsating jet is divided into 20 phases and grabbed total 200 instantaneous velocity fields at each phase. The experiments were performed by varying the frequency, maximum jet velocity and the shape of pulsating jet wave. Pulsating jet was precisely made by piston-type pump controlled by the computer. The obtained results were compared with normal fence flow. From this study, we found there is the specific frequency which is effective in reducing the reattachment region.

  • PDF

대형 입형펌프 운전 중 공진현상의 진동 저감을 위한 스티프너의 설계 및 성능 검증 (Design of stiffeners for reducing resonant vibration of large vertical pumps and its verification)

  • 류길수;봉석근;한승우;노철우;이동민;이정우;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.458-463
    • /
    • 2012
  • This case study refers to resonance with vertical pumps. Vibration problem occurring after the inverter was installed for speed control. Its problem was appeared any revolution under rated speed. Vibration data was acquired during normal operation and transient state. We examined FRF on its resonance in field and also analyzed a result by finite element method. There was carried out the retrofit in field which was based on these results for solving problem.

  • PDF

수평형 지열원 히트펌프 시스템에 관한 연구 (A Study on Horizontal Ground Source Heat Pump Systems)

  • 박용정;김경훈
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.160-165
    • /
    • 2006
  • 지열원 히트펌프 시스템은 난방과 냉방부분에서 두드러진 관심을 보이고 있다. 국내에 설치된 지열원 히트펌프 시스템의 대부분은 수직형 방식으로 연구대상 또한 수직형이 주류이다. 본 연구에서는 수평형 지열원 시스템을 시설하우스에 설치하여 성능을 조사하였다. 연구결과, 히트펌프만 고려한 난방성능계수는 3.64이고 지열순환펌프를 포함한 성능계수는 3.31로 나타났다. 응축기 제거열에 대한 순환펌프의 동력은 28.0 W/kW이고, 열교환기길이는 53.3m/kW였다. 지중으로부터의 평균채열량은 14.58 W/m이고, 응축열에 대한 열교환기가 매립된 트렌치길이는 27.7m/kW였다.

시설원예용 수평형 지열히트펌프의 난방 성능 해석 (Heating Performance of Horizontal Geothermal Heat Pump System for Protected Horticulture)

  • 강연구;유영선;강금춘;백이;김영중
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.30-36
    • /
    • 2007
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house, etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump systems in agriculture, a horizontal geothermal heat pump system of 10 RT scale was installed in greenhouse. Heating performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of 14$^{\circ}C$ for depth of 1.75m and heating COP of 3.75 at soil temperature of 7$^{\circ}C$ for the same depth. The stratification of water temperature in heat tank appeared during the whole heat rejection period.

지열원 물대공기 멀티 히트펌프의 냉방 운전 특성에 관한 실증 연구 (Verification Experiment of a Ground Source Multi-heat Pump at Cooling Mode)

  • 최종민;강신형;최재호;임효재;문제명;권영석;권형진;김록희
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.297-304
    • /
    • 2009
  • The aim of this study is to investigate the cooling performance of ground source multi-heat pump systems with a vertical single U-tube GLHX(U-tube system) and a vertical double tube GLHX(double tube system), which were installed in a school building located in Cheonan. All systems were operated in a part load conditions for all day, and the maximum COP of the single U-tube system and the double tube system were 6.2 and 5.2 at cooling mode, respectively. The double tube GLHX designed by the GLHEPRO, commercial program, was estimated to have the same performance as the U-tube GLHX, because the inlet temperatures of each outdoor unit heat exchanger for the former was similar to the latter. However, it is needed to prove the long tenn performance. It is suggested that the new algorithms to control the flow rate of secondary fluid for GLHX according to load variation have to be developed in order to enhance the performance of the system.

지열 냉난방 시스템의 성능 및 경제성 평가 (Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System)

  • 임효재;송윤석;공형진;박성구
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.296-300
    • /
    • 2004
  • 본 연구는 지열원 물 대 물(water to water)히트 펌프 시스템의 냉방 및 난방 운전시 성능 특성과 경제성 평가에 관한 것이다. 5개의 보어홀당 지중 100m의 깊이로 밀폐 수직형 지중 열교환기(closed-vertical ground source)가 설치된 냉난방 시스템이 적용된 건축물에 대하여 냉난방 운전성능을 평가하였으며, 연간 소비전력을 측정하여 실제 시스템의 경제성을 분석하였다. 또한, 순환수의 입구온도에 따른 시스템의 운전 성능을 분석한 결과 난방시에는 COP가 3.0에서 4.2로 증가한 반면, 냉방시에는 5.0에서 3.7로 감소하였다. 본 실험을 통해서,대상 건축물에 대한 지열 냉난방 시스템의 수명주기비용은 기존 냉난방 시스템(보일러+에어컨)에 비해서 68%까지 절감되었으며, 시스템의 경제성을 고려해 볼 때 기존 건축물에도 지열원 냉난방 시스템을 적용하는 것이 타당하다.

Plant-scale experiments of an air inflow accident under sub-atmospheric pressure by pipe break in an open-pool type research reactor

  • Donkoan Hwang;Nakjun Choi;WooHyun Jung;Taeil Kim;Yohan Lee;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1604-1615
    • /
    • 2023
  • In an open-pool type research reactor with a downward forced flow in the core, pipes can be under sub-atmospheric pressure because of the large pressure drop at the reactor core in the atmospheric pool. Sub-atmospheric pressure can result in air inflow into the pipe from the pressure difference between the atmosphere and the inside of the pipe, which in a postulated pipe break scenario can lead to the breakdown of the cooling pump. In this study, a plant-scale experiment was conducted to study air inflow in large piping systems by considering the actual operational conditions of an advanced research reactor. The air inflow rate was measured, and the entrained air was visualized to investigate the behavior of air inflow and flow regime depending on the pipe break size. In addition, the developed drift-flux model for a large vertical pipe with a diameter of 600 mm was compared with other correlations. The flow regime transition in a large vertical pipe under downward flow was also studied using the newly developed drift-flux model. Consequently, the characteristics of two-phase flow in a large vertical pipe were found to differ from those in small vertical pipes where liquid recirculation was not dominant.