• 제목/요약/키워드: Vertical Plate

검색결과 774건 처리시간 0.025초

아동의 복합운동이 착지 시 하지 손상요인에 미치는 영향 (Effects of Combined Exercise on Injury Risk Factors of Lower Extremity during Landing)

  • 하성희;류시현;김주년;길호종;류지선;윤석훈;박상균
    • 한국운동역학회지
    • /
    • 제24권2호
    • /
    • pp.173-180
    • /
    • 2014
  • The purpose of this study was to investigate the effect of combined exercise on injury risk factors of lower extremity during landing. Ten sports talented athletes participated in this study. Sports talented athletes participated in a combined exercise (sports talented exercise, coordination) for 16 weeks. A three-dimensional motion analysis was performed using eight infrared cameras (sampling rate of 100 Hz), one force plate, and electromyography system (sampling rate of 1000 Hz) during landing. Kinetic, and kinematics analysis including average impulsive force, angle of lower extremity, vertical stiffness, onset of muscle activation were calculated by Matlab2009a software. Paired t-test was performed at alpha=.05. The average impulsive force in landing phase was not statistically significant (t=-.748, p=.474). The hip joint angle was more decreased in post test compared to pre test (E1: t=2.682, p=.025, E2: t=5.609, p=.000, E3: t=2.538, p=.032). The knee joint (E1: t=-.343, p=.739, E2: t=1.319, p=.220, E3: t=.589, p=.570) and ankle joint (E1: t=.081, p=.937, E2: t=.784, p=.453, E3: t=.392, p=.704) angle were tended to decrease after combined exercise. The vertical stiffness was tended to decrease after combined exercise (t=1.972, p=.080). Onset of quadriceps femoris (t=.698, p=.503) and medial gastocnemius (t=1.858, p=.096) were tended to be faster than biceps femoris (t=-.333, p=.747) after combined exercise. Although thses findings were not statistically significant except on a hip joint angle, risk factors of lower extremity such as joint angle, vertical stiffness and onset of quadriceps femoris, medial gastrocnemius were positively changed after the combined exercise but an additional training for improved onset of biceps femoris would be required in the future.

버스계단 내리기 시 구두 힐 높이와 착지거리에 따른 지면반력 파라미터 조사 (Investigation of the Ground Reaction Force Parameters According to the Shoe's heel Heights and Landing Distance during Downward Stairs on Bus)

  • 현승현;류재청
    • 한국운동역학회지
    • /
    • 제24권2호
    • /
    • pp.151-160
    • /
    • 2014
  • The purpose of this study was to investigate the GRF(ground reaction force) parameters according to the shoes's heel heights and ground landing distances during downward stairs on bus. Participants selected as subject were consisted of young and healthy women(n=9, mean age: $21.30{\pm}0.48$ yrs, mean height: $164.00{\pm}3.05cm$, mean body mass: $55.04{\pm}4.41kg$, mean BMI: $20.47{\pm}1.76kg/m^2$, mean foot length: $238.00{\pm}5.37mm$). They were divided into 2-types of shoe's heel heights(0 cm/bare foot, 9 cm) and also were divides into downward stairs with 3 types of landing distance(20 cm, 35 cm, 50 cm). A one force-plate was used to collect the GRF(AMTI, USA) data from the sampling rate of 1000 Hz. The GRF parameters analyzed were consisted of the medial-lateral GRF, anterior-posterior GRF, vertical GRF, loading rate, Center of Pressure(${\Delta}COPx$, ${\Delta}COPy$, COP area) and Dynamic Postural Stability Index(MLSI, APSI, VSI, DPSI) during downward stairs on bus. Medial-lateral GRF and vertical GRF didn't show significant differences statistically according to the shoe's heel heights and landing distance, but 9 cm shoes heel showed higher vertical GRF than that of 0 cm bare foot in landing distance of 50 cm. Also anterior-posterior GRF didn't show significant difference statistically according to the shoe's heel heights, but landing distance of 20 cm showed higher than that of landing distances of 35 cm and 50 cm in anterior-posterior GRF. Loading rate didn't show significant difference statistically according to the landing distance, but 9 cm shoe's heel showed higher than that of 0 cm bare foot during downward stairs. The ${\Delta}COPy$ and COP area didn't show significant differences statistically according to the shoe's heel heights and landing distance, but 0 cm bare foot showed higher than that of 9 cm shoe's heel in ${\Delta}COPx$. Dynamic Postural Stability Index(MLSI, APSI, VSI, DPSI) didn't show significant differences statistically according to the landing distance, but 9 cm shoe's heel showed decreased value than that of 0 cm bare foot in dynamics balance. Considering the above, parameters of GRF showed different characteristics according to the shoe's heel heights and ground landing distances during downward stairs on bus.

토양(土壤) 산성화(酸性化) 정도(程度)에 따른 독일가문비나무(Picea abies [L.] Karst.) (Root Morphology of Norway Spruce (Picea abies [L.] Karst.) in the Differently Acidified Forest Soils)

  • 이도형
    • 한국산림과학회지
    • /
    • 제89권5호
    • /
    • pp.677-684
    • /
    • 2000
  • 본 연구는 토양 특성이 다른 30-40년생 독일가문비나무(Picea abies [L.] KARST) 임분에서 토양 깊이에 따른 뿌리구조 분석을 통하여 뿌리 발달의 차이점과 토양 상태의 상호관계 및 외부 형태적 특징 그리고 기계적 물리적 안정성에 대한 적응범위를 밝히고자 실시하였다. 조사된 3개 임분에 있어서 독일가문비나무의 뿌리구조는 다양한 형태로 관찰되었는데, Eberg$\ddot{o}$tzen 임분은 뿌리수가 많고 가늘며 토양 깊이까지 발달한 뿌리구조를 보였으며, Barbis 임분은 Eberg$\ddot{o}$tzen 임분에 비하여 그 수가 적으나 굵고 깊이까지 자라는 뿌리구조를 나타내었다. 그리고 Weidenbrunnen 임분은 반 수직 뿌리와 편평/접시형 뿌리구조를 나타내었다. 뿌리의 수는 Eberg$\ddot{o}$tzen 임분이 74개로 가장 많은 뿌리 수를 보여주었으며, Barbis 임분은 33개, Weidenbrunnen 임분은 57개이었다. Eberg$\ddot{o}$tzen 임분은 수직뿌리에서 평균 57개로 Barbis 임분이 21개이고, Weidenbrunnen 임분 36개에 비하여 월등히 많은 뿌리의 수를 나타내었다. 뿌리의 길이는 Weidenbrunnen 염분이 전체 뿌리길이가 다른 두 임분에 비하여 길게 나타났으며, 수형뿌리의 길이는 수직뿌리에 비하여 그 값이 107m로 매우 큰 값을 나타내었다. 수직뿌리에 대한 수평뿌리의 비는 Eberg$\ddot{o}$tzen 임분이 다른 두 임분(0.5)에 비하여 그 값이 1.2로 높게 나타났다. 전체 뿌리무게는 다른 두 임분에 비하여 Weidenbrunnen 임분이 매우 높은 값을 보여 주였으며, 수명뿌리에 대한 수직뿌리의 비는 0.16으로 다른 두 임분(0.40)에 비해 매우 낮은 값을 나타내었다. 본 연구의 독일가문비나무 임분에서 나타난 뿌리 발달의 현저한 차이점은 토양의 기계적 물리적 요인보다는 토양 산성화와 같은 화학적인 요인으로 인하여 정상적인 뿌리의 발달이 장애를 받아 수직뿌리생장이 저하되고 수분과 영양분의 스트레스로 언하여 상대적으로 수평뿌리가 발달된 결과로 사료된다.

  • PDF

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

Prediction and analysis of structural noise of a box girder using hybrid FE-SEA method

  • Luo, Wen-jun;Zhang, Zi-zheng;Wu, Bao-you;Xu, Chang-jie;Yang, Peng-qi
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.507-518
    • /
    • 2020
  • With the rapid development of rail transit, rail transit noise needs to be paid more and more attention. In order to accurately and effectively analyze the characteristics of low-frequency noise, a prediction model of vibration of box girder was established based on the hybrid FE-SEA method. When the train speed is 140 km/h, 200 km/h and 250 km/h, the vibration and noise of the box girder induced by the vertical wheel-rail interaction in the frequency range of 20-500 Hz are analyzed. Detailed analysis of the energy level, sound pressure contribution, modal analysis and vibration loss power of each slab at the operating speed of 140 km /h. The results show that: (1) When the train runs at a speed of 140km/h, the roof contributes more to the sound pressure at the far sound field point. Analyzing the frequency range from 20 to 500 Hz: The top plate plays a very important role in controlling sound pressure, contributing up to 70% of the sound pressure at peak frequencies. (2) When the train is traveling at various speeds, the maximum amplitude of structural vibration and noise generated by the viaduct occurs at 50 Hz. The vibration acceleration of the box beam at the far field point and near field point is mainly concentrated in the frequency range of 31.5-100 Hz, which is consistent with the dominant frequency band of wheel-rail force. Therefore, the main frequency of reducing the vibration and noise of the box beam is 31.5-100 Hz. (3) The vibration energy level and sound pressure level of the box bridge at different speeds are basically the same. The laws of vibration energy and sound pressure follow the rules below: web

애스터리스크(*) 배열구조 기반 전력저감 수배전반 (Asterisk(*) Array structure based power reduction power distribution board)

  • 김미숙;박동삼
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.138-144
    • /
    • 2017
  • 오늘날 전력수요 급증에 따른 전력소비량이 증가하고 있어 전력손실을 줄일 수 있는 에너지 저감을 위한 설계 또는 설비 대체로 전력의 고품질화가 필요하다. 배전반이란 한전의 발전설비로부터 전기를 공급받아 각 건물에 필요한 설비에 계통별 또는 용도별로 나누어 주는 기계장치이다. 배전반은 일반적으로 외함, 개폐기, 전력용 도체, 제어부분으로 구성된다. 본 연구는 배전반내의 메인 요소인 통전을 위한 전력용 도체에 관한 것이다. 실효교류저항 측정시험을 통해 기존방식 판상도체의 수직 배열구조가 비효율적 구조임을 입증해 본다. 실효교류저항이 많이 증가하면 표피효과로 인해 상대적으로 도체의 단면적이 커지게 된다. 본 연구는표피효과를 줄여 실효교류저항을 최소화시키는 애스터리스크(*) 배열구조를 기반으로 설계하여 에너지 절약과 원자재 절감을 연구하였다. 본 연구의 핵심기술 원리는 애스터리스크 배열구조를 적용하여 도체저항 감소기술 기반 에너지 절감 수배전반이다. 수배전반의 교류전력 공급용 판상도체 각각(rst 또는 abc)의 상에서 발생한 자기장이 상호작용으로 상쇄 소멸될 수 있도록 한 판상도체 배열구조에 관한 것으로 효과로는 판상도체에서 유도성 리액턴스의 발생량이 줄어들면서 유효단면적이 증가, 실효교류저항을 줄인다.

받침배치에 따른 연속 플레이트 거더 사교의 지진거동 변화 (Variation of Seismic Behavior of Continuous Skew Plate Girder Bridges According to the Arrangement of Bearings)

  • 문성권
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.124-135
    • /
    • 2011
  • 연속교의 교대부와 교각부에 설치되는 받침 용량은 통상적으로 각 지점에 작용하는 최대수직반력의 크기에 따라 결정되며 교각부에 더 큰 용량의 받침이 위치한다. 본 연구에서는 지진격리장치가 적용된 세 가지 받침배치에 따른 사교의 지진거동 변화를 비교 분석하여 연속 사교의 지진성능 향상 가능성을 검토하였다. 기존 받침배치(Case A)를 기준으로 교각부에 설치되는 납고무받침(LRB)의 수평강성에 변화를 주어 세 가지 받침배치(Case A, Case B, Case C)를 선정하였다. 납고무받침 자체의 감쇠효과가 고려된 hybrid response spectrum을 이용한 응답스펙트럼 해석을 수행하여 총 36개의 연속 플레이트 거더 사교들의 지진거동을 조사하였다. 해석결과 교대부에 설치된 LRB와 유사한 수평강성 또는 작은 수평강성을 가진 LRB를 교각부에 설치할 때 훨씬 바람직한 사교의 지진거동이 유발되었다. 즉, 교각부에 설치되는 LRB의 수평강성 변화는 사교의 고유진동주기를 길게 하고 모드형상에 변화를 유발시켜 전체밑면전단력과 교각부에서의 최대밑면전단력 그리고 거더에 걸리는 응력을 크게 감소시킨다. 비록 하부구조의 유연성이 증가할수록 받침배치 변경에 따른 지진거동의 긍정적인 효과가 다소 감소되지만, 10m 미만의 교각 높이를 가지면서 지진격리받침(LRB)이 설치된 연속 플레이트 거더 사교의 경우 제안된 받침배치는 지진성능 향상을 가져온다.

CFRP로 성능향상된 철근콘크리트 보의 Rip-off 파괴메커니즘 고찰 (Rip-off Failure Mechanism of Reinforced Concrete Beams Strengthened with CFRP Plate)

  • 심종성;문도영;박철우;박성재;최광민
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.993-1000
    • /
    • 2005
  • 최근 다양한 FRP를 사용한 철근콘크리트 보의 성능향상은 많이 수행되고 있으며, 특히 CFRP plate 형태로 철근콘크리트 보를 성능향상할 경우 보강재의 성능을 충분히 발휘하지 못하고 조기파괴(rip-on)가 발생되는 경우가 발생하게 된다. 이러한 파괴메커니즘을 규명하기 위하여 많은 실험적$\cdot$이론적 연구자 진행되고 있으나 명확하게 규명되어 있지는 않다. 문헌이나 실험적으로 rip-off 파괴는 주철근위치에서의 수직응력과 전단응력에 기인하여 발생하게 된다. 본 연구에서는 주철근위치에서의 응력모델을 제안하였으며, 제안된 해석모델은 비교적 간단하고, 주철근 위치에서의 수직응력과 전단응력을 기초로 하고 있다. 제안된 모델을 실험결과와 비교한 결과, 제안된 해석모델을 통한 CFRP로 성능향상된 철근콘크리트 파괴하중은 실험 결과와 거의 유사하였다. 따라서 이러한 결과는 CFRP로 보강된 철근콘크리트보의 rip-off 파괴를 제어할 수 있는 보강기법의 기초자료로 활용될 수 있을 것으로 판단한다.

정(${\sharp}$)자형 더블보-기둥 접합부의 전단강도에 대한 4변 구속의 영향 (Effects of Four Sides Constraint for Shear Strength of ${\sharp}$ Shape Double Beam-Column Connections)

  • 김량운;정창용;이수권;김상식;최광호;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.209-212
    • /
    • 2008
  • 건설공사에서 지하공사의 DBS(Double Beam as Struts)공법은 지하 수평부재의 공장제작 및 모듈화 된 부재 생산을 통해 공기를 단축할 수 있으며, 수평재를 영구부재로 사용할 수 있는 장점이있다. 그러나 DBS공법의 구성요소로서 시공 및 사용 시 수평부재에 작용하는 수직하중을 기둥에 전달하기 위하여 개발된 정(${\sharp}$)자형 더블보-기둥 접합부는 복잡한 다축 응력상태의 전단에 의해 지배를 받는다. 이 연구에서는 정(${\sharp}$)자형 더블보-기둥 접합부의 전단파괴 기구와 구속철판 두께에 따른 전단내력 증가를 확인하기 위해 총 7 개의 실험체를 제작하여 1 방향 정적실험을 수행하였다. 실험결과, 실험체는 모두 취성파괴 되었고 실험의 지지조건에 따른 보작용과 아치작용에 의한 전단파괴 양상을 보였으며 철판의 구속이 슬래브의 전단내력을 1.06${\sim}$1.48 배 증가시키는 것으로 나타났다. 또한, 2 방향 구속철판이 동일하지 않은 경우가 구속철판이 동일한 경우보다 전단내력이 더욱 증가한 것으로 나타나 구속철판이 동일하지 않은 경우가 효율적이었다.

  • PDF

삼국시대 토성 판축기법 용어 검토 (Review in terms of the earthen wall stamped technique in the Three Kingdoms period)

  • 신희권
    • 헤리티지:역사와 과학
    • /
    • 제55권4호
    • /
    • pp.38-53
    • /
    • 2022
  • 이 글에서는 삼국시대 토성을 중심으로 축조 기법과, 그 중에서도 판축기법을 둘러싼 개념과 용어를 정리, 검토해 보았다. 연구자별로 토성의 실체 및 축조 방법을 놓고 다양한 개념과 용어들을 사용하여 성격을 규정함으로써 혼란이 야기되고 있기 때문이다. 판축법은 성벽, 담장, 건물의 기단 등을 조성하기 위해 판으로 틀을 만들고 그 안에 흙이나 모래 등을 겹겹이 부어 공이 등으로 찧어서 견고하게 쌓아 올리는 전형적인 고대 토목기법 또는 건축 기법이다. 따라서 판축법으로 토성을 축조하였음을 입증하기 위해서는 성벽 내에서 판목(협판), 이를 고정하기 위한 기둥(고정주), 협판을 받치기 위한 횡장목과 종장목, 흙을 견고히 다진 달구질 흔적 등이 발견되어야 한다. 다만, 국내에서는 이와 같은 증거들이 온전히 발굴된 사례가 극히 적기 때문에 판축에 대한 기준을 얼마나 엄격히 적용할 것인지에 대해서도 합의가 필요한 실정이다. 토성 축조에 동원된 판축기법과 관련된 용어는 그 개념에 관한 용어를 필두로 판축 원리와 판축 단위, 그리고 구체적인 판축 기술과 관련된 용어로 구분하여 실제 사례를 통해 설명하였다. 특히 풍납토성에서는 고대 판축토성 축조에 이용된 전형적이고 다양한 기법들이 확인됨으로 해서 판축 기법의 원리와 기술을 이해할 수 있는 결정적인 자료들을 확보할 수 있었다. 향후 풍납토성 이외의 유적들에서 판축과 관련된 증거들이 더 많이 발견되어야 보다 보편적인 판축 기법의 이해가 가능할 것이다.