• 제목/요약/키워드: Vertical Load

검색결과 1,692건 처리시간 0.023초

Testing of Load Capacity of a Foil Thrust Bearing

  • Kim, Choong Hyun;Park, Jisu
    • Tribology and Lubricants
    • /
    • 제34권6호
    • /
    • pp.300-306
    • /
    • 2018
  • In this study, the performance of foil thrust bearings was investigated by performing bearing take-off and load capacity tests, using an in-house designed and manufactured vertical bearing test rig. The mean take-off rotational speed and maximum load capacity of the bearing specimen were ~18,000 rpm and ~80 kPa, respectively. The vertical bearing test rig was observed to yield higher coefficients of friction and frictional torques than a horizontal bearing test rig under identical test conditions. This was a result of its structural characteristics, in that the bearing specimen is placed atop the thrust runner, which keeps it from being separated from the runner after the bearing take-off. In addition, bearing take-off was observed at a higher runner rotational speed as this structure keeps air from flowing between the top foil and runner surfaces, which requires a higher runner speed. The parallel alignment between the bearing specimen and runner surfaces can be maintained within a certain range more easily in a vertical test rig than in a horizontal test rig. Because of these advantages, Korean Industrial Standard, KS B 2060, recommends a vertical bearing test rig as the standard test device for foil thrust bearings.

시스템 동바리 구조 안전성에 대한 최소 수평하중의 영향 (Effects of Minimum Horizontal Load on Structural Safety of System Supports)

  • 정대현;김경윤;원정훈
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.37-43
    • /
    • 2015
  • This study examined the effects of the minimum horizontal load on the structural behaviors and safety of system supports. The minimum horizontal load was frequently ignored in the design of system supports even though the level of that load was specified in the code and guide in Korea such as 'Standard Specification in Temporary Construction' and 'Guide to Installation of Shores for a Concrete Bridge'. To examine the effects of considering the minimum horizontal load, the finite element analysis were performed for various system supports. By varying installing parameters of system supports such as the vertical member spacing, the installation height, and the thickness of slab, the maximum combined stress ratios were estimated to investigate the structural safety of system supports. The results showed similar axial stress in vertical members but an increase in bending stress with a consideration of the horizontal load. The combines stress ratios are remarkably increased due to the consideration of the horizontal load. Consequently, the system supports, which were initially estimated to be safe when only the vertical loads were considered, were changed to be unsafe in most cases by the effects of the both the vertical and horizontal stresses. Therefore, the minimum horizontal load following the code and the guide is an essential load that could control the structural safety of system supports.

치조골 높이가 다른 임프란트 주위 지지골 응력분석 (Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level)

  • 부수붕;정제옥;이승훈;김창현;이승호
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

Study on failure mechanism of multi-storeyed reinforced concrete framed structures

  • Ahmed, Irfan;Sheikh, Tariq Ahmad;Gajalakshmi, P.;Revathy, J.
    • Advances in Computational Design
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2021
  • Failure of a Multi-storeyed reinforced concrete framed structure occurs when a primary vertical structural component is isolated or made fragile, due to artificial or natural hazards. Load carried by vertical component (column) is transferred to neighbouring columns in the structure, if the neighbouring column is incompetent of holding the extra load, this leads to the progressive failure of neighbouring members and finally to the failure of partial or whole structure. The collapsing system frequently seeks alternative load path in order to stay alive. One of the imperative features of collapse is that the final damage is not relative to the initial damage. In this paper, the effect on the column and beam adjacent to statically removed vertical element in terms of axial force, shear force and bending moment is investigated. Using Alternate load path method, numerical modelling of two dimensional one bay, two bay with variation in storey heights are analysed with FE model in order to obtain better understanding of failure mechanism of multi-storeyed reinforced concrete framed structure. The results indicate that the corner column is more susceptible to progressive collapse when compared to middle column, using this simplified methodology one can easily predict how the structure can be made to stay alive in case of sudden failure of any horizontal or vertical structural element before designing.

자전거 프레임의 소재 및 종류에 따른 피로특성 (Fatigue Characteristics of Bicycle Frames Depending on Types and Materials)

  • 권경배;정성균
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.8-12
    • /
    • 2017
  • Bicycles are very popular sporting goods in these days. Thus, the durability of bicycles is very important for the safety of bicyclists. It is well known that a bicycle frame is a major component which is essential to the safety and performance of a complete bicycle. In this study, the durability of bicycle frames were experimentally investigated under the fatigue load. Eighty bicycle frames with different types and materials were prepared and tested according to EN standards. Three kinds of fatigue loads, that is, pedalling, vertical and horizontal fatigue load, which occur constantly during riding a bicycle, were applied to the bicycle frames. The experimental results show that the horizontal fatigue load was the severest mode to pass EN standard. The pass ratio of horizontal fatigue load test was 45.2%, while the pass ratio of vertical fatigue load test was 100%. Most of cracks were found at the right side of bottom bracket shell and at the intersection area between head tube and down tube. It seems that the experimental results can be applied to improve the safety and performance of a bicycle frame.

보수성을 개선한 복합형 신축이음장치(HRS) 내구성 평가 (Durability Evaluation of Hybrid Expansion Joint System with Improved Replacement)

  • 이정우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.1-7
    • /
    • 2023
  • 기존 신축이음장치 교체 시간을 절감하고, 차선별 부분교체가 가능하도록 보수성을 개선한 신축이음장치 시스템(HRS)에 대하여 실물규모의 수직하중 피로시험과 윤하중 성능실험을 수행하여 내구성을 평가하였다. 수직하중 피로시험결과 레일형 신축이음장치의 최대응력은 170 Mpa이며, 이는 HRS 신축이음장치레일의 항복강도 355MPa의 약 47.8% 수준이다. 보수성을 개선한 HRS 신축이음장치의 수직하중 피로시험은 도로교설계기준에 따라 재하판의 크기와 하중을 설정하였고, 200만회 수직하중 피로시험과 윤하중 성능실험에 있어서 파괴거동을 나타내지 않았으며 그 내구성과 안전성을 확인하였다.

Optimal Vertical Handover Control Policies for Cooperative Wireless Networks

  • Papadaki, Katerina;Friderikos, Vasilis
    • Journal of Communications and Networks
    • /
    • 제8권4호
    • /
    • pp.442-450
    • /
    • 2006
  • Inter-operability between heterogeneous radio access technologies (RATs), in the sense of seamless vertical han-dover (VHO) support with common radio resource management (CRRM) functionalities, has recently attracted a significant research attention and has become a prominent issue in standardization fora. In this paper, we formulate the problem of load balancing between cooperative RAT's as a mathematical program and by trading off a pre-defined delay tolerance per request we propose a vertical handover batch processing (VHBP) scheme. To quantify the performance of the proposed VHBP scheme we compare it with a baseline processing scheme, where each VHO request is processed independently under a number of different network scenarios. Numerical investigations reveal significant net benefits of the proposed scheme compared with the baseline, both in terms of achieved load balancing levels but also with regard to the acceptance rate of the VHO requests.

수직축 선형 영구자석 동기전동기의 질량 추정 (Mass Estimation of a Permanent Magnet Linear Synchronous Motor Applied at the Vertical Axis)

  • 이진우;지준근;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.301-303
    • /
    • 2008
  • Tuning of the speed controller in the linear servo applications needs the accurate information of a mover mass including a load mass. Therefore this paper proposes the mass estimation method of a permanent magnet linear synchronous motor(PMLSM) applied at the vertical axis by using the recursive Least-Squares estimation algorithm. First, this paper derives the deterministic autoregressive moving average(DARMA) model of the mechanical dynamic system used at the vertical axis. Results obtained by the Matlab/Simulink simulation show that the mass of a PMLSM applied at the vertical axis can be accurately estimated both at no-load and at load.

  • PDF

단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE)

  • 황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

수직하중 계측을 위한 FBG센서 기반 스마트 교량 내진장치의 개발 (Development of Smart Seismic Device Using FBG Sensor for Measuring Vertical Load)

  • 장성진;김남식;백준호
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1089-1098
    • /
    • 2012
  • A faulting could be occurred at the end of deck by unexpected loads to bridge bearing after a bridge completion. Serviceability of bridges could be impaired by the faulting which is caused structural damage. Therefore, smart bridge bearing which can continuously observe the supporting points is needed. Some of bridge bearings have been developed for measuring vertical load and vertical displacement by installing sensors in the bearing. In those systems, however it is not easy to be replaced with new sensors when repairs are needed. In this study, the smart bridge bearing of which sensors can be replaced has been developed to overcome such a problem. In this study, strain signals were used for measuring both of vertical displacements and loads. FBG sensors(fiber optic Bragg-grating sensors) have been used for measurement of the strain signals since it is prevented from electronic noise by mediating light, enables the simplification of the measuring cable by multiple measurement, and is easy to place by lightweight and small size. The possibility of use was reviewed for smart bridge bearing based on FBG sensors through tests.