• Title/Summary/Keyword: Vertical Installation

Search Result 366, Processing Time 0.028 seconds

Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle (면진장치 설치각도에 따른 아치구조물의 지진응답)

  • Kim, Gee-Cheol;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.

An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel (병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석)

  • Lee, Bok-Hee;Cho, Sung-Chul;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

Design of a Vertical Lathe for the Improved Stability at High Speed Machining (고속가공의 안정성 향상을 위한 수직선반의 설계)

  • Ro, Seung-Hoon;Shon, Jae-Yul;Ro, Kyung-Ho;Kim, Sung-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1728-1737
    • /
    • 2003
  • The vertical lathe is a very popular machine tool in modem manufacturing industries because of its small area of installation. The small installation area is highly desirable for the flexibility improvement of the manufacturing systems such as FMS, CIM, and IMS. The vertical lathe, however, has much taller height compared to the traditional horizontal lathe, and consequently more severe vibrations. In this study, the structure of a vertical lathe is analyzed to investigate the dynamic properties and further to establish some ideas of the design alteration for the improved dynamic stability even at the higher operating speed. The simulation model is implemented to apply those design alterations for the optimization. The result of this study is not only prosperous but also ready to be applied to the optimum design of various machine tool structures for the improved stability.

Temperature Properties of Vertical Reinforcements in Wall Structures in Relation to the Different Methods of Bubble Sheet Installation in Winter (겨울철 버블시트 포설방법 변화에 따른 벽식구조 수직철근의 온도 특성)

  • Kim, Tae-Woo;Lee, Jea-Hyeon;Kyung, Yeong-Hyeok;Lee, Jong-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.11-12
    • /
    • 2017
  • This study aims to analyze the properties of the temperature change in vertical reinforcements in outdoor wall structures in winter in relation to the different methods of bubble sheet installation, and to subsequently determine the possibility of initial frost damage to the concrete as a result of low temperature. As for the experimental variables, double bubble sheets were used as curing materials, and the curing method was to model the part where the slab and the wall intersect and the rebar is exposed, and to measure the change of temperature around the exposed rebar in accordance with the change of the coating curing. It was found that by employing curing method B, which is to install the bubble sheet between the vertical reinforcements, the most vulnerable area, which is 50mm below(④) the surface of the concrete, would be lowered to sub-zero temperature 20 hours later than when using curing method A, and that therefore it is more effective to install the bubble sheet between the vertical reinforcements for the prevention of initial frost damage.

  • PDF

Structural Analysis of a PCB Substrate System for Semiconductor (반도체용 PCB 기판시스템의 구조해석)

  • Rim, Kyung-Hwa;Yang, Xun;Yoon, Jong-Kuk;Kim, Young-Kyun;Iyu, Sun-Joong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.113-118
    • /
    • 2011
  • According to the high accuracy of semiconductor equipments, PCB substrate with much thin thickness is required. However, it is very difficult to sustain the PCB substrate without deformation in case of horizontal installation, due to low bending stiffness. In this research, new PCB process equipment with vertical installation has been developed in order to solve the problem of PCB substrate damage during etching process. As the main parts of etching system on PCB substrate, PCB substrate and JIG are analyzed through finite element method and experimental test. Through the analysis results of stress state, we could find the optimal JIG design to make the damage as low as possible.

A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis (수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구)

  • Kim, HongRae;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is the result from comparing the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

Property of Long vertical rod according to the different injection point with impulse current (대형 봉상 접지전극의 임펄스 인가위치에 따른 특성)

  • 이복희;장근철;엄주홍;김병근;오성균;길형준
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.369-372
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is remarkedly increased. This paper presents how the impulse and fault current works on the long. vertical ground rods associated with incoming points. When the test current was injected at the bottom of ground rod, the potential waveform of ground rod includes the oscillation with high frequency.

  • PDF

Fractal-Space Multiplexing using Double-Focusing Lens (이중초점렌즈를 이용한 Fractal-Space 다중화)

  • 김수길;황보승
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.243-246
    • /
    • 2002
  • We proposed a new spatio-angularly multiplexed holographic memory system using moving windows and double-focusing lens, which can eleminate crosstalk due to two neighboring moving windows(MW) in the vertical direction of the conventional MW holographic memory system and demonstated its feasibility through optical experiments.

  • PDF

A Study on Vertiport Installation Standard of Drone Taxis(UAM) (드론택시(UAM)의 수직이착륙장(Vertiport) 설치기준 연구)

  • Choi, Ja-Seong;Lee, Seok-Hyun;Baek, Jeong-Seon;Hwang, Ho-Won
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.1
    • /
    • pp.74-81
    • /
    • 2021
  • UAM(Urban Air Mobility) systems have evolved in the form of helicopters in the 1960~1970s, tiltrotors in the 1980s, small aircraft transportation systems in the 2000s, and electric-powered Vertical Take-Off and Landing (eVTOL) in the 2010s; accordingly, the early heliport has evolved to its current form of a Vertiport. Vertical Takeoff and Landing Sites, Vertiports, are important factors for the successful introduction of UAM, along with the resolution of air traffic control (ATC), air security, and noise problems. However, there are no domestic or international installation standards and guidelines yet. Therefore, in this study, installation standards were prepared by referring to domestic and international case studies, ICAO standards, and MIT research papers. The study proposes to establish standards for Final Approach and Takeoff Area (FATO) as 1.5D, 1D for Touchdown and Lift-Off Area (TLOF), and 1.5D for Safety Area (SA). It also proposes to add "UAM Vertiport Installation Standards" to the 「Act on the Promotion and Foundation of Drone Utilization, Drone Act」.

The Variations of Grounding Resistance of the Vertical Electrodes by Soil Models (대지구조 모델에 따른 봉형 접지전극의 접지저항값 변화)

  • Shim, Keon-Bo;Kim, Won-Bae;Seo, Gil-Mo;Cho, Geum-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.57-63
    • /
    • 2012
  • The basic purpose of grounding is for human safety and normal operation of system related to electrical shock hazard by faults of electrical equipments. A grounding electrode is defined as a conducting element that connects electrical systems and/or equipment to the earth. The lowest possible resistance connection to the earth is sought from the grounding electrode. The grounding electrode is the foundation of the electrical safety system. The resistance to ground of vertical electrodes buried in the two deference soil structures has been analyzed for a length of electrodes and soil parameters. The equation of ground resistance of vertical electrodes are Tagg's equation for uniform soil models, and modified equation of Dwight equation for two-layer soil model. In this paper, compared with results of two equations are calculated values of vertical electrode in uniform and two-layer soil models.