• Title/Summary/Keyword: Vertical Flat Plate

Search Result 92, Processing Time 0.023 seconds

An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections (PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구)

  • Lee Dong Keun;Ha Sang-Su;Han Sang Whan;Lee Li Ryung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

Stiffness values and static analysis of flat plate structures

  • Unluoglu, Esref
    • Structural Engineering and Mechanics
    • /
    • v.6 no.4
    • /
    • pp.427-437
    • /
    • 1998
  • Flat plate constructions are structural systems which are directly placed on columns without any beams. Various solution methods have been introduced for the solution of flat plate structures under horizontal and vertical loads. In most of these solution methods, models comprising of one column and one plate have been studied. In other solutions, however, co-behavior of two reciprocal columns has been investigated. In this study, interrelations of all the columns on one storey have been examined. At the end of the study structure consisting of nine columns and four plates has been chosen as a model. Then unit moment has been successively applied to each of these columns and unit moments carried over the other columns have been found. By working out solutions far plates and columns varying in ratio, carry-over factors have been found and these factors given in tables. In addition, fixed-end moment factors on the columns arising due to vertical load were also calculated. Then citing slope-deflection equations to which these results could be applied, some examples of moment and horizontal equilibrium equations have been given.

The Coupling of Conduction with Free Convection Flow Along a Vertical Flat Plate in Presence of Heat Generation

  • Taher, M.A.;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.7
    • /
    • pp.833-841
    • /
    • 2007
  • The aim of this paper is to analyze the conjugate problems of heat conduction in solid walls coupled with laminar free convection flow adjacent to a vertical flat plate under boundary layer approximation. Using the similarity transformations the governing boundary layer equations for momentum and energy are reduced to a system of partial differential equations and then solved numerically using Finite Difference Method(FDM) known as the Keller-box scheme. Computed solutions to the governing equations are obtained for a wide range of non-dimensional parameters that are present in this problem, namely the coupling parameter P. the Prandtl number Pr and the heat generation parameter Q. The variations of the local heat transfer rate as well as the interface temperature and the friction along the plate and typical velocity and temperature profiles in the boundary layer are shown graphically. Numerical solutions have been consider for the Prandtl number Pr=0.70

Reshoring effects on deflections of multi-shored flat plate systems under construction

  • Kang, Su-Min;Eom, Tae-Sung;Kim, Jae-Yo
    • Structural Engineering and Mechanics
    • /
    • v.45 no.4
    • /
    • pp.455-470
    • /
    • 2013
  • RC flat plates that have no flexural stiffness by boundary beams may be governed by a serviceability as well as a strength condition. A construction sequence and its impact on the distributions of construction loads among slabs tied by shores are decisive factors influencing immediate and long term performances of flat plate. Over-loading and tensile cracking in early-aged slabs significantly increase the deflection of a flat plate system under construction. A reshoring work may be helpful in reducing slab deflections by controlling the vertical distributions of construction loads in a multi-shored flat plate system. In this study, a change of construction loads by reshoring works and its effects on deflections of flat plate systems under construction are analyzed. The slab construction loads with various reshoring schemes are defined by a simplified method, and the practical calculation of slab deflections with considering construction sequences and concrete cracking effects is applied. From parametric studies, the reshoring works are verified to reduce construction loads and slab deflections.

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

A Study on the Characteristics of the Floor Impact Noise and Vibration According to Structure Types of Apartment House (공동주택 구조 유형별 바닥진동 및 바닥충격음 특성)

  • Lee, Ku-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.35-39
    • /
    • 2009
  • Recently, the flat-plate structure is widely used because it has many advantages such as reduction of story height, long span etc than the RC rahmen structure. Furthermore, application of the flat-plate is on the increase because of flexible plan unlike wall structure. Long span have been at a disadvantage for vibration serviceability evaluation, however studies about vertical direction vibration of flat-plate structure has not been carried out. This study analysis the characteristics according to slab structure to make an experiment on vibration and floor impact noise for the flat-plate structure in construction performance laboratory in Kolon E&C R&D center, the flat-plate structure applied to the post-tension method, and the wall structure in apartment houses.

  • PDF

Experimental and Computational Studies of the Pulse Wave Impinging upon a Vertical Flat Plate (수직평판에 충돌하는 펄스파에 관한 실험적/수치해석적 연구)

  • 이동훈;김희동;강성황
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.285-291
    • /
    • 2001
  • The impingement of a weak shock wane discharged from the open end of a shock tube upon a flat plate was investigated using shock tube experiments and numerical simulations. Harten-Yee Total Variation Diminishing method was used to solve axisymmetric, unsteady, compressible flow governing equations. Experiments were carried out to validate the present computations. The effects of the flat plate and baffle plate sizes on the impinging flow field over the flat plate were investigated. Shock Mach number was varied in the range from 1.05 to 1.20. The distance between the plate and shock tube was changed to investigate the effect on the peak pressure. From both the results of experiments and computations we obtained a good empirical equation to predict the peak pressure on the flat plate.

  • PDF

Comparative Analysis of Maximum Vertical Reaction Force and Lower Limbs on Drop Landing between Normal and Flat Foot Group

  • Yoo, Kyung-Tae
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.1
    • /
    • pp.222-228
    • /
    • 2011
  • With comparison of maximum vertical reaction force and lower limb on drop landing between normal and flat foot group, this study is to provide fundamental data of the prevention of injury and the treatment of exercise which are frequently occurred on flat foot group's drop landing. The surface electrodes were sticked on lateral gastrocnemius muscle, medial gastrocnemius muscle, tibialis anterior and the drop landing on a force plate of 40cm was performed with a normal group who had no musculoskeletal disease and a flat foot group of 9 people who had feet examinations. Vertical reaction force were significantly statistically different between two groups(p<.001). Muscle activity of lower limbs in all three parts were not statistically different but showed high tendency on average in the flat foot group. The flat foot group had difficulties in diversification of impact burden and high muscle activity. Therefore, it was suggested that muscular strengthening of knee joints and plantar flexions of foot joints which were highly affected in impact absorption will be required.

Prediction of Supersonic Jet Impingement on Flat Plate and Its Application (초음속 충돌제트에 대한 수치적 연구와 응용)

  • Lee K. S.;Hong S. K.;Park S. O.;Bae Y. S.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.225-228
    • /
    • 2002
  • Supersonic jet impingement on a flat plate has been investigated to show the flow physics for different jet heights and to demonstrate the adequacy of the characteristics-based flux-difference Wavier-Stokes code Current study also compares the steady-state solutions obtained with variable CFL number for different grid spacing with the time-accurate unsteady solutions using the inner iterations, displaying a good agreement between the two sets of numerical solutions. The unsteady nature of wall fluctuations due to bouncing of the plate shock is also uncovered for high pressure ratios. The methodology is then applied to a complex vertical launcher system where the jet plume hits the bottom wail, deflects into the plenum and eventually exits through the vertical uptake. Flow structures within vertical launcher system are captured and solutions are partially verified against the flight test data. Present jet impingement study thus shows the usefulness of CFD in designing a complex structure and predicting flow behavior within such a system.

  • PDF

Comparison of Shear Strength Equation for Flat Plates with GFRP Plate (GFRP 판으로 보강된 플랫 플레이트의 전단강도식에 관한 규준의 비교 분석)

  • Kim, Min Sook;Hwang, Seung Yeon;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.247-254
    • /
    • 2014
  • In this study, shear test performed to investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test parameters include the distance between the column face and the first line of GFRP plate and number of GFRP plate vertical strip. The result of test showed that when number of GFRP plate vertical strip was increased, shear strength improved. The shear strength for flat plate reinforced GFRP plate in various codes including ACI 318, BS 8110, EUROCODE 2, and KCI were compared to provide more rational approach for reinforced concrete flat plates with GFRP plate.