Structural Characteristics of Turbulent Diffusion Flame Combusted with Simulated Coal Syngas

  • Park, Byung-Chul;Kim, Hyung-Taek;Chun, Won-Gee
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.350-358
    • /
    • 2002
  • The present work determined the flame structure characteristics of coal syngas combusted inside swirl burners with various nozzle types. Fuel nozzle types are largely classified into two groups of axial and tangential. Experiments were carried out for investigating the effects of fuel nozzle geometry, fuel composition ratio, heating rate, excess air, and degree of swirl on the turbulent diffusion flame structure. To determine the characteristics of the flame structure, axial type fuel nozzle diameter of laboratory-scale combustor is varied to 1.23, 1.96, and 2.95 ㎜ and the direction of tangential type nozzles are varied to radial, clockwise, and counter-clockwise. The comparison of the experimental results was performed to understand functional parameters relating the flame structure. Data analysis showed that the vertical straight flame height generally decreased with increasing swirl number and decreasing axial type nozzle diameter. Flame height established with tangential type nozzle is 3 times shorter than that with vertical type. The flame structures among the 3 different tangential fuel nozzles relatively showed no particular difference. By increasing the heating rate, the width of flame increased generally in both vertical and tangential flame. Within the present experimental parameters of the investigation, flame structure is mainly depends on the nozzle type of the combustor. The visually investigated flame lengths are confirmed through the analysis of temperature profile of each flame.

Analysis of Vertical Combustion and Carbonization Patterns of Floor Materials When Using a Needle Flame (니들 플레임에 의한 바닥재의 수직 연소 및 탄화 패턴의 해석에 관한 연구)

  • Park, Min-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.101-106
    • /
    • 2020
  • This study analyzed flame growth characteristics and carbonization patterns when floor materials were burned vertically using a needle flame produced for this study. It was found that PVC flooring was fire retardant and the area under direct flame contracted inward. Vertical combustion causes solidification in the form of a lump at the bottom and also generates soot in a pattern that progresses upwards. This study found that laminated flooring exhibited no fire retarding characteristics and that the laminated layer of its upper surface was destroyed by fire, causing irregular delamination. The carbonization ranges at the left and right sides were determined to be symmetrical. A vertical combustion test of a sample carpet showed that it exhibited no fire-retarding characteristics. It was observed that if heat accumulated in the carpet, the flame formed an ascending air current, and that when flammable materials were present around the flame, they further accelerated the diffusion of the flame. The carbonization pattern at the carpet surface exposed to direct flame revealed that the carpet surface had melted and had flown downwards and that many tiny holes formed on it.

Interaction of burning droplets with internal circulation (내부순환유동을 고려한 연소하는 액적들의 상호작용)

  • Cho, Chong-Pyo;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.183-191
    • /
    • 2004
  • The burning characteristics of interacting droplets with internal circulation in a convective flow are numerically investigated at various Reynolds numbers. The transient combustion of 2-dimensionally arranged droplets, both the fixed droplet distances of 5 radii to 40 radii horizontally and 4 radii to 24 radii vertically, is studied. The results obtained from the present numerical analysis reveal that the transient flame configuration and retardation of droplet internal motion with the horizontal or vertical droplet spacing substantially influence lifetime of interacting droplets. At a low Reynolds number, lifetime of the two droplets with decreasing horizontal droplet spacing increases monotonically, whereas their lifetime with decreasing vertical droplet spacing decreases due to flow acceleration. This flow acceleration effect is reversed when the vertical droplet spacing is smaller than 5 radii in which decreasing flame penetration depth causes the reduction of heat transfer from flame to droplets. At a high Reynolds number, however, lifetime of the first droplet is hardly affected by either the horizontal droplet spacing or flow acceleration effect. Lifetime with decreasing vertical droplet spacing increases due to reduction of flame penetration depth. Lifetime of interacting droplets exhibits a strong dependence on Reynolds number, the horizontal droplet spacing and the vertical droplet spacing and can be con-elated well with these conditions to that of single burning droplet.

  • PDF

Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame (수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

A Study on Flame Retardant Performance of Vertical Blind and Roll Screen (버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구)

  • Jeong, Hyun Gyu;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This study focuses on two points. First, I have examined the difference on combustion between flame-retardant and non flame-retardant products including vertical blinds and roll screens that are widely used as a substitute for fabric curtains. The second point is to see how long flame-retardant goods can be durable, that is, flame retardant durability after washing in liquid. the experiment on the flame-retardant ability before and after washing of vertical blinds and roll screens that have been used for a long time in fire protection construct. Comparing and analyzing domestic and foreign laws on flame-retardant after the experiment on durability of these products. I aim to draw necessity for increased application of internal laws and regulations on flame-retardant and show how to improve the point at issue. According to the result, clear differences in performance and safety were observed between flame-retardant and non flame-retardant products. flame-retardant materials can prevent things from fire spread without igniting but melting when they've met flame and burnt, In contrast, non flame-retardant material for experiment which size is 120cm long takes less than 3 minutes only to be completely destroyed by fire. However, it was expected for flame-retardant durability of flame-retardant blinds which are not washable to decrease flame-retardant durability after being washed with water, there was no sharp difference. so it is demonstrated that flame-retardant blinds can keep flame-retardant durability. accordingly through the strict course of product we are concerned about keeping durability.

  • PDF

Influence of Combustion Flame on Breakdown Characteristics of Vertical-Model Power Lines (수직배열 모델 전력선의 절연파괴 특성에 미치는 화염의 영향)

  • Park, Kwang-Seo;Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.85-92
    • /
    • 2008
  • Occurring forest fire or burning bushes beneath overhead transmission lines have caused breakdown disturbances of the system in many countries. In this study, experiments for flashover characteristics in the simulated condition of vertical power lines were conducted so as to investigate the reduction in insulation strength caused by combustion flame. As the results of an experimental investigation, it is demonstrated that flame can reduce breakdown voltages of the model lines according to height(h) of flame. The breakdown voltages were decreased with decreasing the height(h) of flame it can be seen that the average reduction of flashover levels, in comparison with the no-flame case, are 46.2[%] for h=9[cm] and 62.5[%] for h=3[cm] when ac voltage is applied.

Effect of Pyrolyzing Fuel Position on Ignition and Flame Propagation in a Cylindrical Enclosure (원형공간내 열분해 연료의 위치변화에 따른 점화 및 화염전파 영향)

  • Han, Jo-Yeong;Kim, Jeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.133-142
    • /
    • 2001
  • Investigation on ignition and flame propagation of pyrolyzing fuel in a cylindrical enclosure is accomplished. The pyrolyzing fuel of cylindrical shape is located in an outer cylinder sustained at high-temperature. Due to gravity, the buoyancy motion is inevitably incurred in the enclosure and this affects the flame initiation and propagation behavior. The radiative heat transfer plays an important role since a high temperature difference is involved in the problem. Therefore in all cases presented here, the intrinsic radiation effects are considered. Numerical studies have been performed over various governing parameters, such as Grashof number, overheat ratio, and vertical fuel eccentricity. Depending on the Grashof number, the flame behavior is found to be totally different: a separated visible flame appears as the Grashof number reaches 10(sup)7. The location of flame onset is also affected by the vertical eccentricity of inner pyrolyzing fuel as well as thermal conditions applied.

Effects of acoustic excitation on the combustion emission characteristics of a non-premixed flame (비예혼합 화염에서 음향 가진이 연소 배출 특성에 미치는 영향)

  • Lee, Kee-Man;Park, Jeong;Cho, Han-Chang
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.878-883
    • /
    • 2001
  • The effects of external excitation with various frequencies and amplitudes on the flame behavior and pollution emission characteristics from a laminar jet flame are experimentally investigated. Measurements of $NO_{x}$ emission indices($EINO_{x}$), performed in unconformed and vertical lifted flame at resonance frequency by strong excitation, have been conducted experimentally. It was also conducted to investigate the effects of excited frequency on $NO_{x}$ emissions with a various frequency ranged 0Hz to 2kHz. From the vertical lifted flame like turbulent of the excited jet with resonance frequency was shown that the dependence of $NO_{x}$ emission could be categorized into three groups: Group 1 of intermediate flame length and relative narrow flame volume yielding low $NO_{x}$ emission, Group 2 of short flame length but large flame volume yielding high $NO_{x}$ emission and Group 3 of long flame length with low temperature contours yielding high $NO_{x}$ emission.

  • PDF

Influence of Pyrolyzing Fuel Disposition on Combustion Phenomena in a Cylindrical Enclosure (원형공간내 열분해 연료의 공간배치가 연소현상에 미치는 영향)

  • Han, Cho-Young;Kim, Jeong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.680-685
    • /
    • 2000
  • Investigation on ignition and flame propagation of pyrolyzing fuel in a cylindrical enclosure is accomplished. The pyrolyzing fuel of cylindrical shape is located in an outer cylinder sustained at high-temperature. Due to gravity, the buoyancy motion is inevitably incurred in the enclosure and this affects the flame initiation and propagation behavior. The radiative heat transfer plays an important role since a high temperature difference is involved in the problem. Numerical studies have been performed over overheat ratio, and vertical fuel eccentricity. The location of flame onset is affected by the vertical eccentricity of inner pyrolyzing fuel as well as thermal conditions applied.

  • PDF

An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires (랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구)

  • Park, Moon-Woo;Hong, Sung-Ho;Choi, Ki-Ok;Choi, Don-Mook;Kim, Soo-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.