• 제목/요약/키워드: Vertical Crack

검색결과 230건 처리시간 0.025초

Fabrication of Wafer-scale Polystyrene (2+1) Dimensional Photonic Crystal Multilayers Via the Layer-by-layer Scooping Transfer Technique

  • 도영락;오정록;이경남
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.11.1-11.1
    • /
    • 2011
  • We have developed a simple synthetic method for fabricating a wafer-scale colloidal crystal film of 2D crystals in a 1D stack based on a combination of two simple processes : the self-assembly of polystyrene (PS) nanospheres at the water-air interface and the layer-by-layer (LbL) scooping transfer technique. The main advantage of this approach is that it allows excellent control of the thickness (at a layer level) of the crystals and the formation of a vertical crack-free layer over a wafer-scale (4 inch). We investigate the optical and morphological properties of the PhC multilayers fabricated using various mono-sized colloidal crystals (250, 300, 350, 420, 580, 720, and 850 nm), and mixed binary colloidal crystals (300/350 and 250/350 nm).

  • PDF

Gross dynamic failure of toppling block structures

  • Wilson, James F.
    • Structural Engineering and Mechanics
    • /
    • 제8권5호
    • /
    • pp.491-504
    • /
    • 1999
  • The initiation of toppling is explored for a uniform stack of blocks that rotates slowly about its mid-base. As the stack passes through its vertical position ($\theta$=0), it is in free-fall rotation, and a critical inclination angle ${\theta}_c$ is reached at which the toppling stack "fails" or begins to crack or separate. For tall stacks (high aspect ratios), two modes of failure are hypothesized, for which the dynamic failure analyses are shown to correlate with experimental results. These block failure modes are similar to those observed for tall, toppling masonry structures with weak binding material between their brick or stone blocks.

고인성섬유 복합모르타르 PC판넬을 활용한 철근콘크리트 골조의 리모델링을 위한 보강시스템 개발 (Development of Rerofitting System for the Remodeling of Reinforced Concrete Frame Using High Ductile Fiber Composite Mortar PC Panel)

  • 하기주;신종학;김윤용;홍건호;양승혁;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.66-69
    • /
    • 2006
  • Three reinforced concrete rigid frames and infilled rigid frames with new retrofitting system were tested under both vertical and cyclic loadings, Experimental programs were carried out to evaluate and improve the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeled in one-third scale size. For specimens(RFHPC, RFAR) designed by the improving of seismic performance of the rigid frame using the high ductile fiber composite PC panel and ALC panel system, load-carrying capacities were increased $1.45{\sim}2.28$ times, and hysteretic behavior was very stable during the final tests in comparison with the standard specimen(SRF).

  • PDF

신소재 및 성능개선 디테일을 활용한 철근콘크리트 골조면내 전단벽의 내진성능 개선기술 (New Technique of Earthquake Resistant Performance of Reinforced Concrete Infilled Shear Wall using New Materials and Advanced Detailing)

  • 하기주;신종학;김윤용;양승혁;홍건호;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.202-205
    • /
    • 2006
  • Three reinforced concrete shear wall and infilled shear wall using retrofitting system were constructed and tested under both vertical and cyclic loadings, Experimental programs were carried out to evaluate and improve the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeled in one-third scale size. For specimens(RWAHC, RWXHC) designed by the improving of seismic performance using the high ductile fiber composite mortar, anchoring, and advanced detailing system for the reinforced concrete shear wall load-carrying capacities were increased $1.1{\sim}1.22$ times in comparison with the standard specimen(SRW).

  • PDF

측면하중을 받는 전단벽 구조물의 극한 거동해석 (Ultimate Load Analysis of Reinforced Concrete Shear Walls)

  • 이명규;정연석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.478-481
    • /
    • 2006
  • Reinforced concrete shear wall is composed of wall, horizontal and vertical flanges. Due to the abrupt change in its geometry, it is difficult to predict the ultimate behaviour of shear wall in the action of lateral forces. For the better understanding of ultimate state, the propagation of crack and inelastic compressive zone are simulated reasonably. In this study, for the improvement of analysis result for shear wall with flanges, analyses are fulfilled with the application of some modelling methods including various material and geometrical models and numerical methods. The results from various modelling methods are compared and the advisable model is proposed.

  • PDF

Experimental and analytical behavior of a prestressed U-shaped girder bridge

  • Wu, Xun;Li, Hui
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.427-436
    • /
    • 2017
  • This paper presents an experimental and analytical investigation on the behavior of a U-shaped girder subjected to operation, cracking and ultimate loads. A full-scale destructive test was conducted on a U-shaped girder to study the cracking process, load-carrying capacity, failure mechanism and load-deformation relationships. Accordingly, the tested U-shaped girder was modeled using ANSYS and a non-linear element analysis was conducted. The investigation shows that the U-shaped girder meets the specified requirements of vertical stiffness, cracking and ultimate load capacity. Unfavorable torsional effect is tolerable during operation. However, compared with box girders, the U-shaped girder has a more transverse mechanical effect and longitudinal cracks are apt to occur in the bottom slab.

A new method for repair of fiber reinforced concrete corbels using steel threaded rods

  • Gulsan, Mehmet Eren;Shaikhan, Mustafa A.
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.165-178
    • /
    • 2018
  • The aim of this study is to investigate the efficiency of using threaded rods and steel profiles to produce a steel confining system for rehabilitation of damaged concrete corbels for the first time in literature. Some of the specimens were repaired by crack repair epoxy before being confined for further enhancement. A total of 19 two sided damaged corbels were used in the study with different mechanical properties and parameters but similar dimensions. The differences were in rehabilitation style, shear span, fiber percentage, reinforcement steel diameter, and concrete strength. The rehabilitated specimens were loaded with vertical load until failure. Four different configurations were used in the investigation. Test results show that the proposed rehabilitation technique is effective to enhance the load capacity of the corbels and to improve their ductility. Moreover, new formulations were proposed to calculate the load capacity of the rehabilitated corbels. A good fit was observed between numerical and experimental results.

반복하중을 받는 철근콘크리트 전단벽체의 접합방식에 따른 구조성능 평가 (Structural Performance Evaluation of Reinforced Concrete Shear Walls with Various Connection Type Under Load Reversals.)

  • 신종학;하기주;권중배;전찬목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 1997
  • In this study, nine reinforced concrete infilled frames involved bare frames were tested during vertical and cyclic loads simultaneously. This test programs were carried to investigate the horizontal strength and the crack propagation in variance with hoop reinforcement ratio. All specimens were modeling in one-third scale size. In this experimental program structural performance of reinforced concrete shear wall were focus at connection types. Based on the test results, the following conclusions are made. In the boundary column member of reinforced concrete shear wall, increasing the ratio of hoop bar in two or three times, in the fully babel type, the shear and horizontal strength of specimens were increased 1.1-1.2 times than that of fully rigid frame. And infilled shear wall specimen were increased 1.17-1.27 times than that. Fully rigid babel type shear wall specimens were increased 5.7~8.0 times, and infilled shear wall specimens were increased about 4.0~5.6 times than that of infilled shear wall specimens.

  • PDF

초고강도 ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$) P.C Bearing Plate 개발에 관한 연구 (A Study on the Development of a Ultra-Strength Precast Concrete Bearing Concrete Bearing Plate)

  • 소현창;정병욱;김재우;문성규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.643-648
    • /
    • 1997
  • P.C Bearing Plate method, corresponding to the existing steel plate build-up method, is developed by the very first in domestic and is applied to the foundation in the HYUNDAI building at Kang-Nam. P. C Bearing Plate produced in ourself P.C plant can stand against vertical load of 7,000ton obtaining allowable force of soil. It is possible to minmize cost expediting, do site assembling and omit unnecessary excavation work by plant prefabrication of foundation member. The purpose of this paper is to study the optimum mixing design of Ultra-high strength concrete ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$), crack control through measuring the heat of hydration, mock up test for the optimum curing method. As mentioned above, developing the Ultra-high strength Precast Concrete Bearing Plate set up successfully in the site foundation work of the HYUNDAI Building at Kang-Nam.

  • PDF

해양구조물의 K-Joint 피로연구 (Fatigue Study of K-Joints for Offshore Structures)

  • 임성우;박노식;조철희;박관규
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.291-296
    • /
    • 2004
  • The paper describes a test program on welded K-joints fabricated from circular hollow section brace members and chords made with API 2W 50 grade steel produced by POSCO. The K-joints were tested for three loading conditions at RIST. The specimens were tested in reaction frame that allowed vertical uniform loading to the structure. From the test, the crack initiation and development were observed and the fatigue failure could be predicted. The results were also compared with the provided S-N curves by DnV.

  • PDF