• Title/Summary/Keyword: Vertical Crack

Search Result 230, Processing Time 0.027 seconds

Strength Characteristics of the Vertical and Inclined Concrete Pole (수직 및 경사 건주된 콘크리트 전주의 강도특성)

  • Wang, Yun-Chan;Kim, Dae-Hak;Park, Joong-Sin;Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.118-124
    • /
    • 2009
  • In order to know the range of install possibles of the horizontal stay without general stay, strength characteristic tests were performed for the Vertical and 80[$^{\circ}$] inclined concrete poles. From the results of one cycle strength tests, the safety factors were 2.8, 2.5 and 2.1 for the poles of general load, heavy load and high strength load, respectively. However, the crack was occurred when the bending bounds of upper part of pole was above 2[$^{\circ}$], and working load was similar to the rated load of pole at this time. Therefore, it could be concluded that the reinforcement by the installation of the stay and the support was necessary certainly, if the bending bounds of pole, which was installed on a solid foundation, are above 2[$^{\circ}$].

A study on the Surface Cracks in the West Stone Pagoda of Gameunsa Temple Site, Gyeongju, Korea: Examples from the second story stone body and the third story capstone (경주 감은사지 삼층석탑(서탑)에 발달한 표면균열에 대한 연구: 2층 탑신과 3층 옥개석의 사례)

  • Jwa, Yong-Joo;Kim, Jae-Hwan;Park, Sung-Cheol
    • The Journal of the Petrological Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.238-244
    • /
    • 2008
  • The west stone pagoda of Gameunsa temple site(National Treasure No. 112) has been seriously damaged by surface weathering, and conservation treatment is needed. In the second story body stone, vertical cracks developed parallel to the main compressional axis. The vertical cracks seem to grow much more with the compression. Chemical and biological weathering along the vertical cracks could have enhanced the crack growth. In the third story capstone, the surface cracks strike toward NE and NW directions, which are intersecting each other. In the eastern and southern parts of the third story capstone, lots of vertical cracks develop along the lines from the axial center to outer rim, whereas horizontal cracks are easily observed at the outer rim of the capstone. On the other hand, a few horizontal cracks develop in the western and northern parts of the third story capstone. This fact indicates that the compression along the vertical axis is not uniform in direction. The west stone pagoda leans toward the east and the south, so it is considered that compression by deviatoric stress prevailed at these directions.

A Experimental Study on Fatigue Behavior of Joints between RC and RSFC subjected to shear (강섬유 보강 철근콘크리트 전단이음부의 피로거동에 대한 실험적 연구)

  • 강보순
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.389-396
    • /
    • 2000
  • Fatigue behavior of shear joints between combined reinforced concrete(RC) and reinforced steel fiber concrete(RSFC) specimens has been experimentally investigated. Experimental parameters used are the amount of steel fiber and the type of shear joint. 6 specimens have been tested under static load, and 8 specimens have been subjected to the fatigue load in a range of 50% and 5 % of the ultimate static load. The purpose of this research is to propose an empirical formula for fatigue shear behavior of combined RC and RSFC structures on the basic of experimental result. It can be observed from experimental result that addition of steel fibers to concrete specimen increases the static ultimate load by approximately 25%, enhances the fatigue behavior, and also reduces vertical and lateral displacements at the shear joint for a given load cycle after the occurrence of first crack.

  • PDF

Improvement and Evaluation of Structural performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame under Load Reversals (반복하중을 받는 철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 구조성능 평가 및 개선)

  • 신종학;하기주;김광연;이희종;남왕교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.541-546
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation of and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-l~3), cumulated energy dissipation capacities wear increased by 1.35~l.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.

  • PDF

Analysis on Heat of Hydration for Height of Shell Concrete Pouring in Reactor Containment Building (원자로건물 외벽 타설 높이 산정을 위한 수화열 해석)

  • Kim, Jwa-Young;Park, Jong-Hyok;Lee, Han-Woo;Bang, Chang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.165-166
    • /
    • 2012
  • A thermal stresses by heat of hydration was analyzed according to a change of a pour height in reactor containment building. In case of more than 3.6m pouring height a crack index by heat of hydration analysis resulted in less than 1 because there is not a construction joint of vertical direction and for a self-restraint effect of circumferential section shape. Therefore detailed consideration on a mixture proportion of binder type, quantity in concrete and selection of a form in seasonal air temperature is needed for a control of tensile stress by heat of hydration.

  • PDF

Development of Technique for Improvement of Earthquake-Resistant Performance of Reinforced Concrete Infilled Masonry Frame (철근콘크리트 프레임면내 조적벽체의 내진성능개선 기술 개발)

  • 신종학;하기주;최민권;권중배;남왕교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1143-1148
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as hysteretic behavior, maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infiiled wall were constructed and tested in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled walls with restraining factors of frame, maximum horizontal capacities were increased by 1.26~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-1), cumulated energy dissipation capacities wear increased by 1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.

  • PDF

A Study on Thermal Shock Characteristics of Functionally Gradient Ceramic/Metal Composites (경사기능성 세라믹/ 금속 복합재료의 열충격특성에 관한 연구)

  • Song, Jun-Hee;Lim, Jae-Kyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2134-2140
    • /
    • 1996
  • This study was carried out to anlayze the heat-resistant characteristics of functionally gradient material(FGM) composed with ceramic and metal. The thermal fracture behavior of plasma-sprayed FGM and conventional coating material(NFGM) was exaimined by acoustic emession technique under heating and cooling. Furnace cooling and rapid cooling tests were used to examine the effect of temperature change under various conditions, respectively. At the high temperature above $800^{\circ}C$, it was shown that FGM gives higher thermal resistance compared to NFGM by AE signal and fracture surface analysis.

Numerical crack modelling of tied concrete columns under compression

  • Bosco, C.;Invernizzi, S.
    • Computers and Concrete
    • /
    • v.10 no.6
    • /
    • pp.575-586
    • /
    • 2012
  • In the present paper the problem of monotonically compressed concrete columns is studied numerically, accounting for transverse steel reinforcement and concrete cracking. The positive confinement effect of the ties on the core concrete is modeled explicitly and studied in the case of distributed or concentrated vertical load. The main aim is to investigate the influence of transverse reinforcement steel characteristics on the column load carrying capacity and ductility, in order to provide an evaluation about some standards requirements about the class and ductility of steel to be used for ties. The obtained results show that the influence of transverse reinforcement steel class of ductility is negligible both on the column load carrying capacity and on its ductility. Also the dissipated energy is basically unchanged. In view of these evidences, some standards requirements about the steel class of ductility to be used for ties appear to be rather questionable.

Temperature effects on brittle fracture in cracked asphalt concretes

  • Ayatollahi, Majid-Reza;Pirmohammad, Sadjad
    • Structural Engineering and Mechanics
    • /
    • v.45 no.1
    • /
    • pp.19-32
    • /
    • 2013
  • Cracking at low temperatures is one of the frequently observed modes of failure in asphalt concretes. In this investigation, fracture tests were performed on cracked asphalt concrete subjected to pure mode I and pure mode II loading at different subzero temperatures. An improved semi-circular bend (SCB) specimen containing a vertical crack was used to conduct the experiments. The SCB specimens produced from the gyratory compacted cylindrical samples were compressively loaded, and critical stress intensity factors, $K_{If}$ and $K_{IIf}$, were then calculated using peak loads obtained from the tests. The experimental results showed that with decreasing the temperature, mode I and mode II critical stress intensity factors increased first but below a certain temperature they both decreased. It was also found that at a fixed temperature, the mode II fracture resistance of the asphalt concrete was higher than its mode I fracture resistance.

The research of application plan for the twist absorption structure type brake holder hanger (비틀림 흡수구조형 제륜자 홀더행거의 적용방안에 관한 연구)

  • Hong Jai-Sung;Ham Young-Sam;Paik Young-Nam
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.903-908
    • /
    • 2004
  • Among welded structure bogies in use for high speed freight car, a part of bogies manufactured in 1999 and 2000 have found problems that crack occurs in its end beam. In case of a freight car the difference of weight between empty and loading conditions are worse than in case of a passenger car. Moreover its brake system is tread brake without second suspension system. Cracks of end beam is supposed to be due to loading by brake system rather than vertical loading by freight. These cracks can make brake system useless and may be a cause of derailment in the worst case. In this study, we have proposed a simple torsion-free brake shoe holder hanger to remove torsion of hanger bracket which was supposed to be one of causes of cracks and performed finite element analyses. Also static load test was applied in torsion free brake shoe holder.

  • PDF