• Title/Summary/Keyword: Vertebral fracture

Search Result 172, Processing Time 0.035 seconds

Efficacy and Safety of Balloon Kyphoplasty in the Treatment of Osteoporotic Vertebral Body Compression Fractures : Compared with Vertebroplasty

  • Yi, Won-Jae;Lee, Jung-Ho;Lee, Hyuk-Gee;Ryu, Kee-Young;Kang, Dong-Gee;Kim, Sang-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2007
  • Objective : Kyphoplasty and vertebroplasty are two minimally invasive procedures for osteoporotic vertebral compression fractures. The purpose of this retrospective study was to compare the radiological findings and clinical outcomes between two procedures. Methods : Osteoporotic vertebral fractures were treated in 76 vertebrae, using kyphoplasty (n=35 vertebrae) and using vertebroplasty (n=41 vertebrae). Fractured vertebral bodies were diagnosed by correlating the clinical symptoms with radiologic study. The responses of pain symptoms were measured by a self-reported Visual Analog Scale (VAS) score. Plain X-rays were checked preoperatively and postoperatively at admission and 6 months. The vertebral body height and kyphotic angle were measured to assess the reduction of the sagittal alignment. Results : The mean pain scores were decreased significantly for both procedures postoperatively, but there were no significant differences between two groups. Kyphoplasty led to a significant reduction of the vertebral body height and improvement of kyphotic angle. There were no neurological deficits after kyphoplasty, but one patient experienced paraparesis after vertebroplasty. During the 6 months follow-up both procedures provided stabilization of the sagittal alignment. Conclusion : Kyphoplasty and vertebroplasty are considered effective minimally invasive techniques for the stabilization of osteoporotic vertebral body fractures, leading to a statistically significant reduction in pain. Kyphoplasty significantly restore sagittal alignment. Also, complications and the incidence of bone cement leakage are significantly lesser than vertebroplasty. Therefore, kyphoplasty seems to be reasonable procedure for osteoporotic vertebral body compression fractures when medical treatment fail.

Usefulness of Fracture Risk Assessment Tool Using Lumbar Bone Mineral Density in Prediction of Osteoporotic Vertebral Fracture

  • Lee, Heui Seung;Lee, Sang Hyung;Chung, Young Seob;Yang, Hee-Jin;Son, Young-Je;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.346-349
    • /
    • 2015
  • Objective : To investigate the value of lumbar bone mineral density (BMD) in fracture risk assessment (FRAX) tool. Methods : One hundred and ten patients aged over 60 years were enrolled and divided into 2 groups as non-osteoporotic vertebral fracture (OVF) and OVF groups. The 10-year-risk of major osteoporotic vertebral fracture of each group was calculated by FRAX tool with femoral and lumbar spine BMDs to compare the usefulness of lumbar spine BMD in prediction of OVF. The blood level of osteocalcin and C-terminal telopeptide (CTX) as markers of activities of osteoblast and osteoclast, respectively were analyzed using the institutional database. Results : In the OVF group, the ratio of patients with previous fracture history or use of glucocorticoid was higher than those in non-OVF group (p=0.000 and 0.030, respectively). The levels of T-score of femur neck and lumbar spine in OVF group were significantly lower than those in non-OVF group (p=0.001 and 0.000, respectively). The risk of OVF in FRAX using femur BMD in non-OVF and OVF groups was $6.7{\pm}6.13$ and $11.4{\pm}10.06$, respectively (p=0.007). The risk of using lumbar BMD in the 2 groups was $6.9{\pm}8.91$ and $15.1{\pm}15.08$, respectively (p=0.002). The areas under the receiver operator characteristic curve in the FRAX risk with lumbar and femur neck BMD were 0.726 and 0.684, respectively. The comparison of osteocalcin and CTX was not significant (p=0.162 and 0.369, respectively). Conclusion : In our study, the 10-year risk of major osteoporotic fracture in the OVF group of our study was lower than the recommended threshold of intervention for osteoporosis. Hence, a lower threshold for the treatment of osteoporosis may be set for the Korean population to prevent OVF. In the prediction of symptomatic OVF, FRAX tool using lumbar spine BMD may be more useful than that using femur neck BMD.

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

The effects of vertebroplasty on adjacent vertebra (척추성형술이 인접 척추체에 미치는 영향)

  • Park, Jung-Soo;Choi, Chul-Hyun;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.746-750
    • /
    • 2007
  • Vertebroplasty has drawn much attention as a medical treatment for the compression fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. However vertebroplasty can cause fracture on adjacent vertebra due to relative stiffness change. This study involves the biomechanical evaluation of the vertebroplasty especially on adjacent vertebral body. The finite element method has been employed to analyze the patient who was treated vertebroplasty under static and dynamic loading. For this study, a three-dimentioal model of the three-level ligamentous lumbar segment ($L1{\sim}L3$)is created from medical image data (CT)and compared with the experimental results in vitro.

  • PDF

Outcome and Efficacy of Height Gain and Sagittal Alignment after Kyphoplasty of Osteoporotic Vertebral Compression Fractures

  • Lee, Tae-One;Jo, Dae-Jean;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.271-275
    • /
    • 2007
  • Objective : Although a significant correction of local kyphosis has been reported previously, only a few studies have investigated whether this correction leads to an improved overall sagittal alignment. The study objective was to determine whether an improvement in the local kyphotic angle improves the overall sagittal alignment. We examined and compared the effects of thoracic and lumbar level kyphoplasty procedures on local versus overall sagittal alignment of the spine. Methods : Thirty-eight patients with osteoporotic vertebral compression fractures who showed poor response to conventional, palliative medical therapy underwent single-level kyphoplasty. The pertinent clinical data of these patients, from June 2006 to November 2006, were reviewed retrospectively. We measured preoperative and postoperative vertebral body heights, which were classified as anterior, middle, or posterior fractured vertebral body heights. Furthermore, the local and overall sagittal angles after polymethylmethacrylate deposition were measured. Results : More height was gained at the thoracic level, and the middle vertebral height regained the most. A significant local kyphosis correction was observed at the fractured level, and the correction at larger spanning segments decreased with the distance from the fractured level. Conclusion : The inflatable balloon kyphoplasty procedure was the most effective in regaining the height of the thoracic fractured vertebra in the middle vertebral body. The kyphosis correction by kyphoplasty was mainly achieved in the fractured vertebral body. Sagittal angular correction decreased with an increase in the distance from the fractured vertebra. No significant improvement was observed in the overall sagittal alignment after kyphoplasty. Further studies in a larger population are required to clarify this issue.

The Prognostic Factors Influencing on the Therapeutic Effect of Percutaneous Vertebroplasty in Treating Osteoporotic Vertebral Compression Fractures

  • Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.16-23
    • /
    • 2009
  • Objective : This retrospective study of 215 patients with 383 symptomatic osteoporotic vertebral compression fractures (VCFs) treated by percutaneous vertebroplasty (PVP), was performed to evaluate the clinical outcomes, and to analyze the various clinical factors affecting these results. Methods : The authors assessed the clinical outcome under the criteria such as the pain improvement, activity, requirement of analgesics, and the patient's satisfaction, and determined the relation to various peri- and intra-operative factors, and postoperative imaging findings. Results : The outcome was determined as 84.2% in relief of pain, 72.0% in change in activity, 65.7% in analgesics use, and 84.7% of satisfaction rate. More severe focal back pain, high uptake bone scan, and the lower mean T-score were related to the better pain relief following PVP. The longer the duration between fracture and PVP, the less severe focal back pain, low uptake bone scan, and leakage of PMMA into the paravertebral space were related to the less improvement in activity. Female and low uptake bone scan showed a correlation with more analgesic use. The longer the duration between fracture and PVP, low uptake bone scan, and the higher the mean T-score were correlated with the less the patients satisfaction. Conclusion : Our study suggests that PVP may be more effective in the acute phase of VCFs, more severe focal pain, and far advanced osteoporosis on BMD. Leakage of PMMA into the paravertebral spcae also could be affecting the surgical results.

Osteoporotic Vertebral Compression Fracture Associated with Pregnancy and Lactation in Young Women (젊은 여성에서 임신 및 수유와 연관된 골다공증성 척추 압박골절)

  • Shin, Woo-Jin;Suh, Seung-Pyo;Yeom, Ji-Ung;Kim, Yun-Seong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.266-271
    • /
    • 2021
  • Osteoporosis associated with pregnancy and lactation is a rare disease that can cause osteoporotic vertebral compression fracture (OVCF). Patients usually complain of severe back pain, which is easily mistaken for pain due to pregnancy, childbirth, and lactation, making a rapid diagnosis and treatment difficult. The authors diagnosed OVCF related to pregnancy and lactation through a physical examination, simple radiography, whole-body bone scan, magnetic resonance image, bone marrow density, and blood tests in a 29-year-old female patient and a 31-year-old female patient who presented with low back pain. This paper reports two cases of symptom improvement through a teriparatide injection, wearing thoracic lumbar sacral orthosis and taking calcium and vitamin D with a review of the literature.

Safety and Efficacy of Bone Cement (Spinofill®) for Verte-broplasty in Patients with Osteoporotic Compression Fracture : A Preliminary Prospective Study

  • Park, Han Byeol;Son, Seong;Jung, Jong Myung;Lee, Sang Gu;Yoo, Byung Rhae
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.730-740
    • /
    • 2022
  • Objective : Although several commercialized bone cements are used during percutaneous vertebroplasty (PVP) for patients with osteoporotic vertebral compression fracture (OVCF), there are no reports using domestic products from South Korea. In this study, we investigated the safety and efficacy of Spinofill® (Injecta Inc., Gunpo, Korea), a new polymethyl methacrylate product. Methods : A prospective, single-center, and single-arm clinical trial of 30 participants who underwent PVP using Spinofill® for painful thoracolumbar OVCF was performed with 6-months follow-up. Clinical and surgical outcomes included the Visual analog scale (VAS), Korean-Oswestry disability index (K-ODI), and Odom's criteria, complication rate, and recurrence rate. Radiological outcomes were evaluated by measuring the findings of postoperative computed tomography and simple radiograph. Results : The pain of VAS (from 8.95±1.05 to 4.65±2.06, p<0.001) and the life quality based on K-ODI (from 33.95±5.84 to 25.65±4.79, p<0.001) improved significantly, and successful patient satisfaction were achieved in 20 patients (66.7%) 1 day after surgery. These immediate improvements were maintained or more improved during the follow-up. There was no surgery- or product-related complications, but OVCF recurred in two patients (6.7%). Favorable cement interdigitation was reported in 24 patients (80.0%), and extra-vertebral cement leakage was reported in 13 patients (43.0%). The mean vertebral height ratio (from 60.49%±21.97% to 80.07%±13.16%, p<0.001) and segmental kyphotic angle (from 11.46°±8.50° to 7.79°±6.08°, p=0.002) improved one day after surgery. However, these short-term radiological findings somewhat regressed at the end. Conclusion : The overall outcomes of PVP using Spinofill® were as favorable as those of other conventionally used products.

Percutaneous Vertebroplasty Following Postural Reduction in Unstable Vertebra Plana; Is it a Contraindication?

  • Kim, Seok-Won;Lee, Seung-Meung;Shin, Ho;Kim, Hyun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.2
    • /
    • pp.92-95
    • /
    • 2006
  • Objective : Severe vertebral body collapse [vertebra plana] is considered a contraindication to vertebroplasty by most authors. The purpose of this study is to determine the efficacy of vertebroplasty in treating severe compression fracture patients with osteoporosis. Methods : 16 patients underwent 18 vertebroplasties following postural reduction for vertebra plana. The fractures were defined vertebrae that have collapsed to more than 75% of their original height. Imaging and clinical features were analyzed, including involved vertebrae level, vertebral height after postural reduction for 2 days, injected cement volume, clinical outcome and complications. Results : Involved veretebra were located from level T7 to L4. Vertebral body collapse averaged 79% [range $12{\sim}25%$] of the original height. After pillow reduction for 2 days, vertebral body height increased 35% of the original height [range $15{\sim}45%$]. The kyphotic wedge was $12^{\circ}$ before procedure and was decreased $7.0^{\circ}$ after vertebroplasty. The mean injected cement volume was 3.8ml [range $2.0{\sim}4.9ml$]. After the procedure, surgical outcome was excellent in 8 [50%] of 16 patients, good in 7 [42%] and unchanged in one [8%]. The mean pain score [VAS score] prior to vertebroplasty was 8.3 and it changed 3.2 after the procure. Cement leakage to the adjacent disc [5 cases] and paravertebral soft tissues [4 cases] developed but there were no major complications. Conclusion : We propose that vertebra plana due to osteoporosis is not a contraindication to vertebroplasty. Vertebroplasty following postural reduction for severe compression fracture is safe and effective treatment.