• 제목/요약/키워드: Vents

검색결과 142건 처리시간 0.023초

외기유인형 주방·욕실 배기구의 기류측정 분석 (Analysis of Air Current Measurements at External Induction-Style Kitchen and Bathroom Vents)

  • 이용호;김성용;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.76-84
    • /
    • 2012
  • This study conducted experiments to measure air currents in an experimental building according to external conditions, types of induction ducts, and types of internal sockets by applying an external induction duct comprised of inducing openings and lines and induction units to the kitchen and bathroom vents at the rooftop of a super high-rise apartment building in order to help to improve the venting performance. The study also proposed the optimization of the external induction-style kitchen and bathroom vents capable of wind power generation. (1) As for air current distribution according to vent velocity changes, it increased the venting performance of the kitchen and bathroom by 1.0m/s at vent velocity of 2.0m/s or higher and allowed for wind power generation. (2)As for air current distribution according to external velocity changes, it increased the venting performance of the kitchen and bathroom by 1.2m/s at external velocity of 2.0m/s or higher and allowed for wind power generation. (3)As for air current distribution according to wind direction changes($0{\sim}180^{\circ}$), it was favorable for higher vent velocity when the angle between the external induction duct direction and prevailing wind direction was within ${\pm}30^{\circ}$. (4)As for air current distribution according to induction duct type, the[M1] type combining the inducing openings and lines with the induction units recorded the highest improvement effects in the kitchen and bathroom venting performance by increasing vent velocity by 46%. (5)As for air current distribution according to the changing types of internal sockets where the main ducts of the kitchen and bathroom are connected to the external induction ducts, the venturi tube type[Sv] increased vent velocity by 66% based on the smoothest external inflow.

저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구 (Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels)

  • 홍기배;나준영;유홍선
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.619-625
    • /
    • 2019
  • 저심도 터널에서는 온도차에 의한 부력을 이용한 자연배기시스템이 많이 사용되고 있지만 이는 연기배출을 인위적으로 조절할 수 없다. 그러므로 자연배기시스템에서는 수직환기구에서 연기 배출량이 설계된 연기 배출량보다 적어지는 Plug-holing 현상을 고려한 설계가 필수적이다. Plug-holing 현상은 터널과 수직환기구의 형상 위치, 화원의 위치와 발열량 등에 영향을 받는다. 본 연구에서는 터널과 자연 환기구의 단면적 비와 화원의 열방출률이 자연배기시스템에서 발생하는 Plug-holing 현상에 미치는 영향에 대하여 실험적으로 분석하였다. 1/20 크기로 축소시킨 실험모델에서 터널과 수직환기구의 종횡비는 고정시키고 터널과 수직환기구의 단면적 비를 달리하여 Plug-holing 현상에 미치는 영향을 확인하였다. 화원의 열방출율은 0.55 kW, 0.98 kW, 1.67 kW로 고정시켰다. 실험결과, 연기 경계층온도와 수직환기구 내의 온도와의 비교를 통한 Plug-holing 발생을 판단하였고, 터널과 수직환기구의 단면적 비가 증가함에 따라서 수직환기구 하부의 유동과 온도분포 특성이 변함을 확인하였다. 터널 화재 시 Plug-holing 현상은 터널과 수직환기구의 단면적 비에 영향을 받으며 단면적 비가 클수록 Plug-holing 발생 가능성이 증가하였다.

절삭식 정미기의 절삭롤러 통풍구 수와 송풍속도에 따른 정백특성 (The Milling Characteristics of Cutting Type Rice Milling Machine Depending on the Number of a Cutting Roller's Air Vent and Blowing Velocity)

  • 조병효;강신형;원진호;이희숙;강태환;이동일;한충수
    • 산업식품공학
    • /
    • 제21권2호
    • /
    • pp.110-115
    • /
    • 2017
  • 본 연구에서는 절삭식 정미기의 절삭롤러에 장착된 통풍간극링의 통풍구 수와 정백 중 발생하는 미강제거에 필요한 흡인 송풍속도가 정백특성에 미치는 영향을 구명하여 절삭식 정미기 개발의 기초자료를 제시하고자 하였다. 그 결과를 요약하면 다음과 같다. 백도는 모든 조건에서 $38{\pm}0.5$로 측정되어 균일하게 정백된 것으로 나타났다. 정백 후 곡온 상승은 송풍속도가 증가할수록 곡온 상승이 낮아지는 경향을 보였고, 절삭롤러 통풍구 수 3구, 송풍속도 35, 40 m/s 조건에서 각각 $15.4^{\circ}C$ $14.6^{\circ}C$로 나타났다. 동할미율은 절삭롤러 통풍구 수 3구, 송풍속도 35 m/s 조건에서 2.13%로 가장 낮게 측정되었다. 싸라기율은 모든 조건에서 0.762-0.869%로 낮은 범위를 보였다. 백미 1 ton을 생산하기 위한 에너지 소비량은 송풍속도가 증가할수록 감소하는 것으로 나타났다. 따라서 절삭식 정미기의 절삭롤러 통풍구 수와 미강제거를 위한 흡인 송풍속도에 따른 적정 정백조건은 곡온, 동할미율, 싸라기율의 품질적인 측면과 에너지 소비량 등을 고려할 경우 절삭롤러 통풍구 수 3구, 송풍속도 35 m/s 조건이 적절한 것으로 판단된다.

쓰레기 매립지에서 가스유출 계산에 관한 연구 (A Study on Numerical Calculation of Gas Migration from the Sanitary Landfill)

  • 이해승
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.43-51
    • /
    • 1998
  • This study presents a numerical method for calculating gas flow around a sanitary landfill gas vent, when gas flows by pressure. The method described is a three-dimensional compartmental model and includes methods to determine the dimensions for the model. Using the numerical method, controll of press and gases flowing out to the air through final cover soil, and degine of sanitary landfill gas vents.

  • PDF

통기구 유무와 옷 길이 차이에 따른 건설현장 작업복의 온열생리반응 (Thermo-physiological Responses by Presence of Vents and Difference in Clothing Length for Construction Site Working Clothes)

  • 김성숙;김희은
    • 한국의류산업학회지
    • /
    • 제20권2호
    • /
    • pp.202-209
    • /
    • 2018
  • This study examined thermo-physiological responses according to the design change of construction site working clothes (control (C) working clothes; prototype (P) working clothes). We measured rectal temperature, skin temperature, micro-climate within the clothes and sweat rate. In the evaluation of physiological functionality, based on pattern improvement in working clothes, P working clothes showed significantly lower rectal temperatures, trunk and thigh skin temperatures than C working clothes. It is preferable that rectal temperature should be kept low during work that is not favorable to an increase in body temperature. P working clothes were more physiologically functional than C working clothes. In addition, P working clothes showed significantly lower temperatures in the trunk and thigh parts in a micro climate temperature. We could explain that the side seam zipper on the pants and the gusset on armpit parts create an air permeability effect of lowering the temperature of micro-climate. Aggressive ventilation through the slit of the garment is an important factor for the restoration of the physiological function of the worker at rest between work. Sweat rate showed a higher level in C working clothes than P working clothes. When working in a hot environment, workwear needs to be designed so that the worker is not exposed to thermal stress. Therefore, it was evaluated that the P work clothes used in this study alleviated the physiological burdens of heat.

환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석 (Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses)

  • 허종철;임종환;서효덕;최동호
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.27-39
    • /
    • 2000
  • 본 실험에 앞서, 하우스 4개동에 대한 대칭성 실험을 실시하였으나, 각 하우스간에는 최대1$^{\circ}C$이내의 작은 온도차만이 계측되었다. 하우스 개폐장치 조작 불능시를 가정하여 천.측창을 인위적으로 폐쇄한 경우, 하우스 내 온도는 외 기온보다 약 16$^{\circ}C$ 높은, 즉 사실상 작물이 생육 할 수 없는 고온상태를 나타내었다. 천.측창을 개방한 상태에서는 환기팬을 추가로 가동시키더라도 이에 따른 추가적인 실온저하는 관찰되지 않았다. 비교적 분무 입경이 큰 스프링클러에 의한 환수시의 냉각효과를 검토한 결과, 하우스 내 온도는 스프링클러 작동과 동시에 급속히 하강함으로서, 관수는 하우스 실온저하에 크게 기여하고 있음이 확인되었다. 스프링클러 관수시와 비관수시로 구분하여 하우스 내 열환경을 비교한 결과, 관수시와 비관수시 모두 하우스의 천.측창을 개방하여 외기를 도입한 경우가 하우스 실온 저하에 효과적으로 작용한 것으로 조사되었다. 하우스 내 작물 체감온도에 근사한 온도지표인 실내 흑구온도는 비관수시의 경우 실내 공기온도보다 현저히 놀게 나타났으나, 관수시의 온도는 실내 공기온도에 근접한 온도를 나타내었다. 비관수시 천.측창을 개방한 경우 하우스 내 온도분포는 연직방향, 수평방향 모두 1$^{\circ}C$ 정도의 극히 작은 온도차만이 계측됨으로서, 하우스 내는 극히 균일한 온도를 유지하고 있음이 확인되었다

  • PDF

열수 플룸 검출을 위한 CTD Cast와 CTD Tow-yo 방법 비교 (Comparison of CTD Cast and CTD Tow-yo Methods for Detecting Hydrothermal Plume)

  • 손주원;주종민;함동진;양승진;김종욱
    • Ocean and Polar Research
    • /
    • 제36권2호
    • /
    • pp.179-187
    • /
    • 2014
  • Directly searching for undiscovered hydrothermal vent sites is inefficient due to the practical difficulty of comprehensively imaging vent fields. Thus, most searches for hydrothermal vent sites rely on the detection of hydrothermal plumes from water column observation. Detecting and measuring the hydrothermal plumes are the most efficient way to infer the presence and distribution of hydrothermal vents. Both the array of vertical casting and lateral towing are the most common methods to discover hydrothermal plumes. In this study, we compared results of cast and tow-yo operations along the same section of a spreading center with a distance of 20.5 km in the North Fiji Basin for mapping hydrothermal plumes. Operation of CTD tow-yo provides a detailed pattern of plumes which enable us to locate the hydrothermal vents. On the other hand, identification of hydrothermal activity can be determined effectively by CTD cast with additional analysis of geochemical tracers. Reduction in the operating time is another advantage of CTD cast operation, especially for regional-scale survey. Our results show that the combination of CTD cast and tow-yo would improve the efficiency of the hydrothermal plume survey to locate new hydrothermal vent sites.

섬유방향성을 고려한 복합소재 대차 프레임의 RTM 성형 특성 해석 (Analysis of RTM Process to Manufacture Composite Bogie Frame Considering Fiber Orientation)

  • 김무선;김정석;김승모
    • 한국철도학회논문집
    • /
    • 제18권4호
    • /
    • pp.301-308
    • /
    • 2015
  • 철도차량의 경량화 일환으로 대차 프레임 스킨제작에 복합소재를 적용하여 RTM 기법으로 제조하는 방안을 검토하였다. RTM 기법은 공정설비의 단순화 및 복잡한 형상의 대형 구조물을 짧은 시간에 제조할 수 있는 장점이 있다. RTM 공정에서는 구조물에 기공이 갇힐 수 있기 때문에 수지 주입구와 배출구의 개수 및 위치 선정이 중요하다. 이번 연구에서는 섬유 프리폼의 투과성 계수를 등방성과 이방성 특성으로 구분하여 RTM 성형특성을 수치해석을 통해 예측하였다. 그로부터 투과성 계수에 따른 기공 형성과 성형 시간의 예측 및 수지 배출구의 최적 위치 등 공정조건을 선정하기 위한 대차 프레임 스킨의 RTM 성형 충전패턴을 분석하였다.

초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구 (A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building)

  • 박상훈;조가영;이선우;조재훈;여명석;김광우
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

Internal pressure in a low-rise building with existing envelope openings and sudden breaching

  • Tecle, Amanuel S.;Bitsuamlak, Girma T.;Aly, Aly Mousaad
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.25-46
    • /
    • 2013
  • This paper presents a boundary-layer wind tunnel (BLWT) study on the effect of variable dominant openings on steady and transient responses of wind-induced internal pressure in a low-rise building. The paper presents a parametric study focusing on differences and similarities between transient and steady-state responses, the effects of size and locations of dominant openings and vent openings, and the effects of wind angle of attack. In addition, the necessity of internal volume correction during sudden breaching, i.e., a transient response experiment was investigated. A comparison of the BLWT data with ASCE 7-2010, as well as with limited large-scale data obtained at a 'Wall of Wind' facility, is presented.