• Title/Summary/Keyword: Ventilation volume

Search Result 310, Processing Time 0.029 seconds

Different PEEP Effects on Lung Volume According to Underlying Lung Disease in Patients with Auto-PEEP (자가 호기말 양압(auto-PEEP)을 보인 환자에서 원인질환에 따른 PEEP적용 효과의 차이)

  • Sohn, Jang Won;Koh, Younsuck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.567-572
    • /
    • 2004
  • Background : The effect of PEEP(ed note: Define PEEP.) on the lung volume in patients with auto-PEEP during mechanical ventilation is not even. In patients with an expiratory limitation such as COPD, a PEEP of 85% from an auto-PEEP can be used with minimal increase in the lung volume. However, the application of PEEP to patients without an expiratory flow limitation can result in progressive lung. This study was carried out to evaluate the different PEEP effects on the lung volume according to the different pulmonary diseases. Methods : Sixteen patients who presented with auto-PEEP during mechanical ventilation were enrolled in this study. These patients were divided into 3 groups: asthma, COPD and tuberculosis sequela (patients with severe cicatrical fibrosis as a result of previous tuberculosis and compensatory emphysema). A PEEP of 25, 50, 75 and 100% of the auto-PEEP was applied, and the lung volume increments were estimated using the trapped lung volume. Results : In the asthma group, the trapped lung volume was not increased at a PEEP of 25 and 50% of the auto-PEEP. This group showed a significant lung volume increment from a 75% PEEP. In the COPD group, the lung volume was increased only at 100% PEEP. In the tuberculosis sequela group, the lung volume was increased progressively from low PEEP levels. However, a significant increment of the lung volume was noted only at 100% PEEP. Conclusion : The effects of the applied PEEP on the lung volume were different depending on the underlying lung pathology. The level of the applied PEEP >50% of the auto-PEEP might increase the trapped lung volume in patients with asthma.

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation (박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Cheong, Jae-Woan;Choi, Gyeong Lee
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation (Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가)

  • Choe, Youngtae;Park, Jinhyeon;Kim, Eunchae;Ryu, Hyoensu;Kim, Dong Jun;Min, Kihong;Jung, Dayoung;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.627-635
    • /
    • 2020
  • Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

The Effects of Chest Physiotherapy on Sputum Amount, Lung Compliance, Tidal Volume and Oxygen Saturation of Intensive Care Unit Patients Mechanical Ventilated (흉부물리요법이 인공호흡기환자의 객담량, 폐유순도, 일회호흡량 및 산소포화도에 미치는 효과)

  • Seo, Kyoung-San;Kwon, En-Ok
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.15-25
    • /
    • 2009
  • Purpose: This study investigated the effects of chest physiotherapies on intensive care unit patients mechanical ventilated. Methods: Good lung down position, chest percussion, postural drainage was applied to patients who admitted to ICU. Each patients divided into four groups and each group received different treatments. Sputum amount, lung compliance, tidal volume and oxygen saturation were measured before treatment and immediately, and time flowing. Data was analyzed with frequency, percentage, ANOVA and paired t-test using via SPSSWIN 12.0 program. Results: There were significant differences in variables each characteristics of subjects. Chest percussion increased tidal volume, static lung compliance for the mean time. Desaturation related to suction. Conclusion: Chest percussion influences on lung compliance. Based on this study results and limitation, this study suggests repeated studies in various groups

  • PDF

Analysis of cardiopulmonary resuscitation during main stretcher transport - A manikin study - (이동 중 주들것에서 심폐소생술 분석)

  • Roh, Sang-Gyun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.2
    • /
    • pp.39-50
    • /
    • 2020
  • Purpose: This study aimed to compare the effect of chest compression and the resulting ventilation volume in walking cardiopulmonary resuscitation (CPR), straddling CPR, and mechanical CPR while moving manikins to main stretchers. Methods: We compared the chest compressions in terms of compression depth, number of incomplete releases, complete release depth, compression rate, duration between peak time of previous compression and peak time of current compression, and respiration. We analyzed the compression comparatively with the ventilation volume in three different types of CPR. Results: The chest compression depth was significantly improved during straddling CPR as compared to walking CPR, during which women were unable to achieve sufficient chest compression depth. A constant chest compression depth was maintained during mechanical CPR. Conclusion: High-quality chest compressions were difficult to achieve in moving spaces. Further, walking CPR may be helpful in men, but straddling or applying automatic chest compressions in women would result in more effective CPR. Our findings demonstrate the limitations and trends in administering CPR in men and women, which may be useful in devising better education and training methods in the future.

A Study on the Smoke control Design parameter of Large Volume space by Fire Dynamic Simulation (화재 시뮬레이션(FDS)을 이용한 대형공간의 제연 설계인자에 관한 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.237-243
    • /
    • 2018
  • Performance-oriented design has been introduced in fire protection design, and various efforts have been made to minimize the damage caused by fire in the design stage. We conducted a study to provide information for reasonable design factors using a Fire Dynamic Simulation code provided by the NIST on boundary width and amount of supply. This paper shows that using a living-room air-supply system in a large space and dividing the space by a ventilation boundary are the two factors that are considered to have the greatest influence on the design of the living room ventilation. The results show that for performance-based design, the width of the ventilation boundary is designed to be the maximum limit in the initial design. It is judged that reasonable air volume determination should be made through various methods.

Analysis of Differences in Indoor Environment and Fatigue Response According to Ventilation in Lecture Hall (대형강의실의 환기여부에 따른 실내환경과 피로감 반응의 차이분석)

  • Oh, Ye-Seul;Hwang, Jin-A;Choi, Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.2
    • /
    • pp.417-428
    • /
    • 2010
  • The purpose of this study was to analyze differences of the indoor environment and student's fatigue response according to ventilation in university lecture hall. The experiments consisted of measuring the indoor environmental parameters and a survey of student's responses. The experiments were in the lecture hall that the actual lecture was conducted in on the $25^{th}$ of May 2009 (not opening windows and door- A) and the $1^{st}$ of June 2009 (opening windows and door- B). The experimental variable was ventilation by opening the windows and door, and the controlled conditions were indoor temperature by air conditioner, volume of the microphone and VTR, lighting conditions and teaching method. The results are as follows: 1) The indoor temperature was maintained in controlling A, B but the $CO_2$ and relative humidity of A (average 3579ppm, 62.6%) was higher than B (average 1697ppm, 48.1%). 2) There were differences in the student's subjective responses and student's fatigue responses between A and B. 3) Therefore, it was found that ventilation by opening the windows and door was a valid way to improve the relative humidity and to reduce $CO_2$ in the lecture hall.