• Title/Summary/Keyword: Ventilation rate

Search Result 821, Processing Time 0.034 seconds

Effects of Combination of Air Temperature and Soil Moisture Contents on Growth, Clove Initiation, Physiological Disorders, and Yield of Garlic (기온과 토양수분 함량에 따른 난지형 마늘의 생장, 인편분화, 생리장해 및 수량에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Mun, Boheum;Lee, Jin Hyoung;Lee, Hee Su;Kwon, Young Seok;Han, Ji Won;Kim, Cheol Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.191-198
    • /
    • 2018
  • The objective of this study was to determine the effects of combination of air temperature and soil water contents on growth, physiological disorder rate, and yield of garlic. This experiments has been carried out in the typical plastic house (one side open and other side installed ventilation fans) which was maintained gradient air temperature (maximum different value of air temperature : $6^{\circ}C$). The excessive irrigation (EI) set at $0.34m^3/m^3$ soil moisture contents. The significant differences found in the growth parameters of garlics as affected by air temperature and soil moisture conditions. The plant height of garlic with combination of ambient $(A)+6^{\circ}C$ and optimal irrigation (OI; set at $0.22m^3/m^3$ soil moisture contents) treatments represented 47.4 cm/plant, which was the highest among all the tested treatments. The leaf length and width showed the greatest, which were 16.1 and 2.4 cm/plant, respectively, in $A+6^{\circ}C-OI$. The physiological disorder ratio was higher as 12.9% at $A+6^{\circ}C-OI$ and was not occurred at ambient temperature with EI compared with OI treatment. The bulb and clove weight were dramatically decreased at $A+6^{\circ}C$ temperature treatment. The yields were decreased by 51% in OI at $A+6^{\circ}C$ and $A+3^{\circ}C$ temperature treatment. Those results indicated that yields were decreased and ratio of physiological disorders was increased by high temperature treatments.

Comparison of the Reconstruction Routes after Esophagectomy for Esophageal Cancer (식도암 절제후 식도 재건경로의 비교)

  • Lee, Seung-Yeoll;Kim, Kwang-Taik;Choi, Young-Ho;Kim, Il-Hyun;Baik, Man-Jong;Sun, Kyung;Lee, In-Sung;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.806-812
    • /
    • 1999
  • Background: Selection of reconstruction route in esophageal cancer surgery is based on the patient's status, characteristics of tumor, surgeon's preference and experience. Of the various routes, it has been documented that subcutaneous or substernal route may prolong operation time and may be vulnerable to postoperative respiratory complications. This study was designed to evaluate whether the selection of reconstruction route affects the surgical outcomes. Material and Method: Of 131 patients who have undergone resection and reconstruction for esophageal cancer, posterior mediastinal route(Group I, n=34), substernal route (Group II, n=31), and subcutaneous route(Group III, n=21) were retrospectively reviewed in 86 patients. Results of early operations and morbidities were compared between the groups. Result: There was a male prevalence(79 of males vs. 7 of females). There were 81 squamous cell cancers and 5 adenocarcinomas. There were no differences between groups in weight, height, age, cancer staging and location, and in the preoperative anesthetic risk evaluation and pulmonary function test(p=NS). Postoperative mechanical ventilation time was longer in Group I(20.6 hours) than in Group II(7.8 hours) or III(3.4 hours)(p=0.005). Duration of stay in the intensive care unit was prolonged in Group III(6.4 days) compared to Group I (3.9 days) or II(3.1 days)(p=0.043). No differences were noted in the duration of hospital stay between the groups(p=NS). Blood transfusion was needed in 30 out of 34 patients in Group I compared to 14/31 in Group II or 15/21 in Group III(p=0.001). The mean amount of transfusion for each patient was also higher in Group I(3,833 mL) than in Group II(1535 mL) or Group III(1419 mL)(p=0.04), but there was no difference in the inreoperation due to bleeding. Ea ly mortality rate was substantially higher in Group I(17.6%) but the differences between the groups were insignificant(p=NS). Although sepsis was a more prevalent cause of death in Group I, it was not related to anastomotic leak. Other morbidities did not differ between the groups(p=NS). Conclusion: In above results show that the reconstruction route does not affect the outcome of esophageal cancer surgery. We believe that the selection of reconstruction route can be based on the surgeon's preference and experience.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

The Study of Effectiveness of MERS on the Law and Remaining Task (국내 메르스(MERS) 사태가 남긴 과제와 법률에 미친 영향에 대한 소고(小考))

  • Yoon, Jong Tae
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.2
    • /
    • pp.263-291
    • /
    • 2015
  • In May, 2015, a 68 years old man, who has been Middle East Saudi Arabia and the United Arab Emirates, had high fever, muscle aches, cough and shortness of breath. he went two local hospital near his house and the S Medical Center emergency center. He was diagnosed MERS(Middle East respiratory syndrome) and the diseases had put South Korea the fear of epidemics for three months. Especially, this disease has firstly reported in Middle East Asia in September 2012 and spreaded to twenty-six countries. In 21, July, 2015, European Center for disease prevention and control reported 533 people were died and in South Korea, 186 people were infected, 36 people were died and 16,693 people were isolated from MERS. South Korea government were faced into epidemic control and blamed from public. Especially, hospital acquired infection, disease control chain, opening of information, ventilation, lack of isolation bed, the problem of function of local health center, the issue of reparation for hospital and insurance cover rate, the classification of disease, the role of Korea Centers for disease control and prevention, the culture of visiting hospital to see sick people, the issue of hospital multiple room and other related social support policy. it is time to study and discuss to solve these problems. South Korea citizens felt fear and fright from MERS. What is wore, they thought the dieses were out of their government control. It was unusual case for word except Middle East Asia. numerous tourists canceled visiting korea. South korea economic were severly damaged especially, tourism industry. South korea government should admit that they had failed initial action against MERS and take full reasonability from any damages. The government have to open information to public in terms of epidemic diseases and try to prevent any other epidemic diseases and try to work with local governments.

  • PDF

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

Role of Invasive Procedures in the Diagnosis and Management of Pulmonary Infiltrates in Patients with Leukemia (백혈병 환자에서 발생한 폐침윤의 진단 및 치료에 있어 침습적 검사의 역할)

  • Kang, Soo-Jung;Park, Sang-Joon;An, Chang-Hyeok;Ahn, Jong-Woon;Kim, Ho-Cheol;Lim, Si-Young;Suh, Gee-Young;Kim, Ho-Joong;Kwon, O-Jung;Lee, Hong-Ghi;Rhee, Chong-H.;Chung, Man-Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.448-463
    • /
    • 2000
  • Background : Pulmonary infiltrate is a frequent cause of morbidity and mortality in patients with leukemia. It is often hard to obtain a reliable diagnosis by clinical and radiologic findings alone. The aim of this study was to evaluate diagnostic and therapeutic benefits of invasive procedures for new lung infiltrates in leukemia. Methods : Patients with leukemia who developed new lung infiltrates from December 1994 to March 1999 were included in this study. These patients were classified into the empirical group who received empirical therapy only and into the invasive group who underwent bronchoscopy or surgical lung biopsy for the diagnostic purpose of new lung infiltrates. A retrospective chart review was done to find the etiologies of new lung infiltrates, the yield of invasive procedures, outcome as well as predicting factors for survival. Results : 1) One hundred-two episodes of new lung infiltrates developed in 90 patients with leukemia. Invasive procedures were performed in 44 episodes while 58 episodes were treated with empirical therapy only. 2) Invasive procedures yielded a specific diagnosis in 72.7%(32/44), of which 78.1% had infectious etiology. Therapeutic plan was changed in 52.3%(23/44) of patients after invasive procedures. None of them showed procedure-related mortality. 3) The overall survival rate was 62.7%(64/102). Survival rate in the invasive group (79.5%) was significantly better than that in the empirical group (50.0%) (p=0.002). 4) Upon multivariate analysis, the performance of invasive procedures, no need for mechanical ventilation and achievement of complete remission of leukemia after induction chemotherapy were the independent predicting factors for survival in patients with leukemia and new lung infiltrates. Conclusion : Bronchoscopy and surgical lung biopsy are useful in the diagnosis of new lung infiltrates in patients with leukemia. However, survival benefits of invasive procedures should be considered together with disease status of leukemia and severity of respiratory compromise.

  • PDF

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

The Predictable Factors for the Mortality of Fatal Asthma with Acute Respiratory Failure (호흡부전을 동반한 중증천식환자의 사망 예측 인자)

  • Park, Joo-Hun;Moon, Hee-Bom;Na, Joo-Ock;Song, Hun-Ho;Lim, Chae-Man;Lee, Moo-Song;Shim, Tae-Sun;Lee,, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.356-364
    • /
    • 1999
  • Backgrounds: Previous reports have revealed a high morbidity and mortality in fatal asthma patients, especially those treated in the medical intensive care unit(MICU). But it has not been well known about the predictable factors for the mortality of fatal asthma(F A) with acute respiratory failure. In order to define the predictable factors for the mortality of FA at the admission to MICU, we analyzed the relationship between the clinical parameters and the prognosis of FA patients. Methods: A retrospective analysis of all medical records of 59 patients who had admitted for FA to MICU at a tertiary care MICU from January 1992 to March 1997 was performed. Results: Over all mortality rate was 32.2% and 43 patients were mechanically ventilated. In uni-variate analysis, the death group had significantly older age ($66.2{\pm}10.5$ vs. $51.0{\pm}18.8$ year), lower FVC($59.2{\pm}21.1$ vs. $77.6{\pm}23.3%$) and lower $FEV_1$($41.4{\pm}18.8$ vs. $61.l{\pm}23.30%$), and longer total ventilation time ($255.0{\pm}236.3$ vs. $98.1{\pm}120.4$ hour) (p<0.05) compared with the survival group (PFT: best value of recent 1 year). At MICU admission, there were no significant differences in vital signs, $PaCO_2$, $PaO_2/FiO_2$, and $AaDO_2$, in both groups. However, on the second day of MICU, the death group had significantly more rapid pulse rate ($121.6{\pm}22.3$ vs. $105.2{\pm}19.4$ rate/min), elevated $PaCO_2$ ($50.1{\pm}16.5$ vs. $41.8{\pm}12.2 mm Hg$), lower $PaO_2/FiO_2$, ($160.8{\pm}59.8$ vs. $256.6{\pm}78.3 mm Hg$), higher $AaDO_2$ ($181.5{\pm}79.7$ vs. $98.6{\pm}47.9 mm Hg$), and higher APACHE III score ($57.6{\pm}21.1$ vs. $20.3{\pm}13.2$) than survival group (p<0.05). The death group had more frequently associated with pneumonia and anoxic brain damage at admission, and had more frequently developed sepsis during disease progression than the survival group (p<0.05). Multi-variate analysis using APACHE III score and $PaO_2/FiO_2$, ratio on first and second day, age, sex, and pneumonia combined at admission revealed that APACHE III score (40) and $PaO_2/FiO_2$ ratio (<200) on second day were regarded as predictive factors for the mortality of fatal asthma (p<0.05). Conclusions: APACHE III score ($\geq$40) and $PaO_2/FiO_2$ ratio (<200) on the second day of MICU, which might reflect the response of treatment, rather than initially presented clinical parameters would be more important predictable factors of mortality in patients with FA.

  • PDF