• Title/Summary/Keyword: Ventilation rate

Search Result 829, Processing Time 0.026 seconds

Maximum Oxygen Consumption Determined by the Bruce and Inclined Treadmill Protocols

  • Kim, Kyu-Hwa;Kim, Hyeong-Jin;Kim, Kyoung-Soon
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.209-215
    • /
    • 1993
  • The aim of the present study was to derive regression equations for $\dot{V}o_{2max}\;vs.\;\dot{V}o_{2peak},\;and\;\dot{V}o_2\;vs.$ heart rate, exercise time, and other variables from maximal exercise tests on a treadmill using the Bruce and inclined protocols. Twelve male and 10 female Korean college students aged between 19 and 23 years voIunteered for this study. After the resting measurements, the subjects performed a maximal exercise on a treadmill according to the Bruce protocol. When the resting conditions were restored, the subjects performed another maximal exercise according to an inclined protocol where the speed was fixed at 8.05 $km{\cdot}h^{-1}$ and the grade was incremented starting from 09t by 2.5% for every 2 min. Peak $\dot{V}o_2$ observed during the Bruce exercise $(\dot{V}o_{2peak})$ was $37.7{\pm}2.4\;and\;31.7{\pm}1.8\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Peak $\dot{V}o_2$ observed during the inclined exercise was higher than $\dot{V}o_{2peak}$ during the Bruce exercise. Maximum $\dot{V}o_2$ value observed during the tyro exercises $(\dot{V}o_{2max})$ was $43.0{\pm}2.8\;and\;36.2{\pm}1.4\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Thus, $\dot{V}o_{2peak}$ by the Bruce protocol was about 12% (male) or 13% (female) lower than $\dot{V}o_{2max}$, and a linear relationship was found between $\dot{V}o_{2peak}$ and $\dot{V}o_{2max}$. The peak values of % $\dot{V}o_{max}$ with the Bruce protocol were $89.2{\pm}3.3\;and\;87.5{\pm}3.6%$ and those with the inclined protocol $97.7{\pm}1.8\;and\;96.9{\pm}2.0%$ in the male and female groups, respectively. In the female group, $%\dot{V}o_{2max}$ at a given workload was higher than in the male group, while $\dot{V}o_{2}$ per kg body weight was the same. Maximum HR observed during the two exercises was $204{\pm}2\;and\;195{\pm}3\;beat\;min^{-1}$ in the male and female groups, respectively. Linear relationships were found, excluding the last points, between 1) $\dot{V}o_{2}$ and exercise time, 2) $\dot{V}o_{2}$ and $%\dot{V}o_{2max}\;and\;%HR_{max}$.

  • PDF

Effect of Floor Space Allowance on Pig Productivity across Stages of Growth: A Field-scale Analysis

  • Lee, Joon H.;Choi, Hong L.;Heo, Yong J.;Chung, Yoon P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.739-746
    • /
    • 2016
  • A total of 152 pig farms were randomly selected from the five provinces in South Korea. During the experiment, the average temperature and relative humidity was $24.7^{\circ}C$ and 74% in summer and $2.4^{\circ}C$ and 53% in winter, respectively. The correlation between floor space allowance (FSA) and productivity index was analyzed, including non-productive sow days (NPD), number of weaners (NOW), survival rate (SR), appearance rate of A-grade pork (ARA), and days at a slaughter weight of 110 kg (d-SW) at different growth stages. The objectives of the present study were i) to determine the effect of FSA on the pig productivity index and ii) to suggest the minimum FSA for pigs based on scientific baseline data. For the pregnant sow, NPD could be decreased if pregnant sows were raised with a medium level (M) of FSA (3.10 to $3.67m^2/head$) while also keeping the pig house clean which improves hygiene, and operating the ventilation system properly. For the farrowing sows, the NOW tended to decrease as the FSA increased. Similarly, a high level of FSA (H) is significantly negative with weaner SR of farrowing sows (p-value = 0.017), indicating this FSA tends to depress SR. Therefore, a FSA of 2.30 to $6.40m^2/head$ (very low) could be appropriate for weaners because a limited space can provide a sense of security and protection from external interruptions. The opposite trend was observed that an increase in floor space (> $1.12m^2/head$ leads to increase the SR of growing pigs. For the fattening pigs, H level of FSA was negatively correlated with SR, but M level of FSA was positively correlated with SR, indicating that SR tended to increase with the FSA of 1.10 to $1.27m^2/head$. In contrast, ARA of male fattening pigs showed opposite results. H level of FSA (1.27 to $1.47m^2/head$) was suggested to increase productivity because ARA was most affected by H level of space allowance with positive correlation ($R^2=0.523$). The relationship between the FSA and d-SW of fattening pigs was hard to identify because of the low $R^2$ value. However, the farms that provided a relatively large floor space (1.27 to $1.54m^2/head$) during the winter period showed d-SW was significantly and negatively affected by FSA.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

The Real Fire Test in Bedroom for the Performance Based Fire Design (성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험)

  • Kim, Hyung-Jun;Kwon, In-Kyu;Kweon, Oh-Sang;Kim, Heung-Youl;Chae, Seung-Un
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.32-37
    • /
    • 2013
  • For The performance based fire design of the buildings, the fire characteristic such as proceeding and scale of the fire should be figured out but, there is lack of relevant information because of different conditions and difficulties of mock-up test like type of division space, ventilation condition, etc, in buildings. Therefore, in the study, a heal release rate etc, the engineering characteristic data value on the fire is proposed by mock-up fire test for division space in buildings. The mock-up fire test is carried out in a bedroom with 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m model. Initial ignition was started from trash box and the test was carried out for 30 min. As a result of the fire test, flame was broken to outside within 7 min and 50 s after starting the test and the maximum heat release rate was measured as 3,810.6 kW at 9 min and 34 s.

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

Estimation of Humidifier Disinfectant Amounts Inhaled into the Respiratory System (가습기 살균제 피해자 호흡기로 흡입된 가습기 살균제 양 추정 - 호흡기 외부(external) 및 내부 노출(internal exposure) 추정 방법과 사례 -)

  • Park, Dong-Uk;Ryu, Seung-Hun;Lim, Heung-Kyu;Kim, Sun-Kyung;Roh, Hyun-Suk;Cha, Won-Seok;Park, Dooyong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • In South Korea, many cases of humidifier disinfectant-associated lung injury (HDLI) have been reported among people who used humidifier products containing humidifier disinfectant (HD). The objectives of this study are to estimate both airborne HD concentration in the room where HD was used and the amount of humidifier disinfectant absorbed into the respiratory system. Information and data on the HDs were collected using a structured questionnaire and home environmental investigations include the volume of HD (ml) and hours used per day, concentration of disinfectants contained in the HD brand (${\mu}g/ml$), volume of the room ($m^3$), assumed ventilation rate ($m^3/hr$) and breathing rate assumed ($m^3/hr$). We used children aged under five years old as a sample and estimated both airborne HD concentrations and amount of HD absorbed into the respiratory system. The estimated airborne concentration of HD in the room ranged from 68 to $369{\mu}g/m^3$ for PHMG (polyhexamethylene guanidine phosphate) and from 16 to $239{\mu}g/m^3$ for PGH (oligo (2-(2-ethoxy) ethoxyethyl guanidine). The amount of HD absorbed in the respiratory system per day was estimated to range from 227 to $1,225{\mu}g$ for PHMG and from 53 to $794{\mu}g$ for PGH. In conclusion, a great amount of HD was likely absorbed into respiratory system, likely beyond the level of the capacity of the immune system to remove the HD absorbed.

Hemodynamics Effects of $CO_2$ Insufflation During Thoracoscopy (흉강경시 $CO_2$에 의한 혈역학적 영향)

  • 손동섭;원경준
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.723-727
    • /
    • 1996
  • An adequate exposure is important in thoracoscopic procedures. The insufflation of $CO_2$has been demonstrated to aid in compressing lung parenchyma, and act as a retractor when combined with changes in patient's position. However, a recent study demonstrated that $CO_2$insufflation during thoracoscopy in the pig has adverse hemodynamic consequences. We prospectively studied 12 patients undergoing thoracoscopy to evaluate the effect of $CO_2$insufflation in the clinical setting. The mean arterial pressure, heart rate, central venous pressure, arterial oxygen saturation, and end-tidal $CO_2$pressure were monitored. Measurements were determined at baseline, at the initiation of one-lung ventilation, and at intrapleural pressure of 5, 10, 15 mmHg and following results were obtained. 1) The insufflation of 5 to 15 mmHg of $CO_2$had no significant effect on the mean arterial pressure, heart rate, arterial oxygen saturation. 2) The end-tidal $CO_2$pressure rose from 31.00$\pm$1.67 mmHg to 38.49$\pm$1.82 mmHg at an intrapleural pressure of 15 mmHg(p<0.05). 3) The central venous pressure rose from 7.75$\pm$0.76 mmHg to 12.83$\pm$1.64 mmHg and 16.16$\pm$l.97mmHg at an intrapleural pressure of 10 and 15 mmHg(p<0.05). 4) The low pressure (<10 mmHg) insufflation is a safe adjunct to the conduct of thoracoscopic surgical procedures.

  • PDF

The Changes of Psychological and Physiological Emotional Responses According to Change of the Index of Predicted Mean Vote (PMV) due to Air Conditioning Types (공조방식에 의한 예상 온열감 반응(PMV) 변화에 따른 심리/생리적 감성반응의 변화)

  • Kim, Bo-Seong;Min, Yoon-Ki;Min, Byung-Chan;Kim, Jin-Ho
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.645-652
    • /
    • 2011
  • This study examined changes of both psychological and physiological emotional responses according to change of the PMV (predicted mean vote) in the heating and the cooling air conditions. For this purpose, the changes of PMV were induced by the heating and cooling operations of the HVAC (heating, ventilation, and air conditioning) systems. In addition, positive/negative and arousal/relaxation were measured as the participant's psychological emotional responses, and HR (heart rate) was measured as the participant's physiological emotional responses. As a result, in same range of the PMV, both psychological and physiological emotional-responses were changed by air conditioning. It is suggested that occupant's emotional responses would depend on the operational conditions of heating and cooling in indoor thermal environments, and both psychological and physiological emotional response should be considered when occupants try to match the indoor thermal environments to their thermal expectations.

  • PDF

The Relationships between Allergy and Weakness in Children in Seong-Dong District (성동구내 어린이집 어린이의 알레르기 질환과 허약아의 실태 및 관련성에 대한 보고)

  • Park, You-Jin;Yoon, Ji-Yeon;Myoung, Sung-Min
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.112-125
    • /
    • 2010
  • Objectives The purpose of this study is to find the relationships between the allergy and weakness in children in Seong-Dong district. Methods 802 day care centers children were participated for survey on allergic disease, risk factors, and weakness. From the result, we analyzed the relationships between the aforementioned factors. Results 1. 802 children were participated for the survey. We eliminated survey answers with unclear answers, and selected 792 survey sheets as our final subject of study. The age of majority of subjects(720 children) were between one to six years old, and the others were under the age of one and over seven. 2. The prevalence rate of asthma in a lifetime was 6.69%, allergic rhinitis was 14.87%, atopic dermatitis was 28.82%, allergic conjunctivitis was 6.29%, food allergies was 9.58%, and drug allergies was 1.4%. In 2009, the prevalence rate of allergies during treatments is 6.69% for asthma, 13.41% for allergic rhinitis, 13.64% for atopic dermatitis, 4.13% for allergic conjunctivitis, 5.23% for food allergies, 0.96% for drug allergies. 3. The significant risk factors were types of dwelling, pet with fur, dirty environments without vacuum cleaners, the numbers of times bed covers were washed, frequency of air ventilation, changes in body after moving, family history. 4. The distribution of the number of children with weakness within the five visceras were respiratory weakness, digestive weakness, psychoneurologic weakness, neuromotor weakness, and urogenital weakness in the order of most to the least. More specifically, children who only has respiratory weakness were the majority, while children who have respiratory and digestive weaknesses, children who have respiratory, digestive, and psychoneurologic weaknesses, children who have respiratory and psychoneurologic were followed. 5. With the exception of children with urogenital weakness, Most of the children with respiratory weakness, digestive weakness, psychoneurologic weakness, and neuromotor weakness had been treated for allergies in 2009, while children who were diagnosed with allergic diseases at least once in their lifetime most likely had weak respiratory, digestive or psychoneurologic systems. Conclusions The results of this study showed that there was a correlation between children with weak viscera and children with allergic diseases. However, further research would be necessary.

Numerical Study on Indoor Dispersion of Radon Emitted from Building Materials (건축자재로부터 방출되는 라돈의 실내 확산에 대한 수치해석적 연구)

  • Park, Hoon Chae;Choi, Hang Seok;Cho, Seung Yeon;Kim, Seon Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • Growing concerns about harmful influence of radon on human body, many efforts are being made to decrease indoor radon concentration in advanced countries. To develop an indoor radon reduction technology, it is necessary to develop a technology to predict and evaluate indoor inflow and emission of radon. In line with that, the present study performed computational modelling of indoor dispersion of radon emitted from building materials. The computational model was validated by comparing computational results with analytical results. This study employed CFD (Computational Fluid Dynamics) analysis to evaluate the radon concentration and the airflow characteristics. Air change rate and ventilation condition were changed and several building materials having different radon emission characteristics were considered. From the results, the indoor radon concentration was high at flow recirculation zones and inversely proportional to the air change rate. For the different building materials, the indoor radon concentration was found to be highest in cement bricks, followed by eco-carats and plaster boards in the order. The findings from this study will be used as a method for selecting building materials and predicting and evaluating the amount of indoor radon in order to reduce indoor radon.