Gas Fuelled Ship FGS 시스템에 대한 가스누출 조건 검토 및 CFD 해석 (Gas Leakage Condition and CFD analysis on Gas Fuelled ship FGS system)

  • 김기평;강호근;박재홍;정정호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2011
  • According to the requirement of Res.MSC.285(86) for natural gas-fueled engine installations in ships, pump and compressor rooms should be fitted with effective mechanical ventilation system of the under pressure type, providing a ventilation capacity of at least 30 air changes per hour. It generally considered that gas leakage is more likely from a Fueled Gas Supply System(FGS) room as compared to other places, where installed in many kind of machinery or equipments like gas supply high-pressure pipes, valves, flanges and etc. Furthermore, leaked gas may be dispersed in a short time in an enclosed space, especially a FGS room, due to high pressure. However, the present requirement in Res.MSC.285(86) just considers the ventilating capacity of air changes per hour but the capacity of leaked gas. Hence, the current requirements may not meet effectively when enforcing the new propulsion systems as marine fuel. This study is conducted for the purpose of safety evaluation about the dispersion and ventilation efficiency with estimated leakage scenario. Numerical analysis predictions as the result of this paper are explained to know the features of flow pattern and the diffusion of natural gas concentration.

  • PDF

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

누출 수소 환기에 영향을 미치는 요인별 환기 특성에 관한 수치해석적 연구 (A Numerical Study on Ventilation Characteristics of Factors Affecting Leakages in Hydrogen Ventilation)

  • 이창용;조대환
    • 해양환경안전학회지
    • /
    • 제28권4호
    • /
    • pp.610-619
    • /
    • 2022
  • 수소는 산소와 반응하여 전기에너지를 만들고 부산물로 물을 생성하므로 친환경 선박의 대체 연료로 대두되고 있다. 그러나 수소는 일반 화석연료와는 달리 낮은 점화 에너지와 높은 가연성 범위로 인하여 폭발의 위험성이 높은 물질이다. 그래서 선박에서 사용되는 수소의 안전성을 확보하기 위해서 수소의 누출·확산에 관한 유동 특성을 연구하는 것은 매우 중요하다. 본 연구에서는 선박 내부와 같은 밀폐공간에서 수소가 누출되었을 때 누출량, 통풍량, 환기 방식 등이 환기 성능에 어떤 영향을 미치는지에 대하여 수치적 해석을 수행하였다. 수치해석에는 CFD 상용 소프트웨어인 ANSYS CFX ver 18.1을 이용하였다. 누출량은 1 q = 1 g/s로 하여 1 q, 2 q, 3 q로 변경하였고, 통풍량은 1 Q = 0.91 m/s로 하여 1 Q, 2 Q, 3 Q로 변경하였으며 환기 방식은 typeI, typeII, typeIII로 변경하면서 환기 성능을 분석하였다. 누출량이 1 q에서 3 q로 증가할수록 저장실 내의 수소 몰분율(HMF)는 약 2.4 ~ 3.0배 높게 나타났으며 통풍량 증가는 누출량에 대비하여 약 62.0 ~ 64.8 % 정도 환기 성능이 개선에 효과가 있었다. 그리고 폭발의 위험성을 낮추기 위한 통풍량은 최소 2 Q 이상 되어야 하며, 수소탱크 저장실 내부의 부압 형성을 위해서는 type III가 가장 적합한 방식이라고 판단하였다.

시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구 (Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads)

  • 노광철;장재수;오명도
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구 (An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference)

  • 한동훈;김영식;정한식;정효민;최순호
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.

PIV에 의한 냉장고 기류특성 평가방법 (A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV)

  • 김석로;도덕희;이재근;김경천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향 (Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building)

  • 김기연;서성철;최정학
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

폐교를 활용한 노인복지시설의 평면유형개발에 관한 연구 - 충북지역을 중심으로 - (A Study on the Development of Plan Types of Elderly Welfare Facility Using Closed Schools - In Case of Chungbuk Province -)

  • 김학래
    • 한국농촌건축학회논문집
    • /
    • 제21권1호
    • /
    • pp.45-52
    • /
    • 2019
  • Since 1980's, Countless schools across the nation, particularly in rural areas, have been closed down by the large fall in number of students. Otherwise, an elderly population has been increasing rapidly, so the demand for welfare services for the elderly population is also increasing. However, the supply of elderly welfare facilities remains inadequate. The purpose of this study is to propose remodelling plan of elderly welfare facility using Closed schools. The result of this study were as follows; in unit-based facility plans, Single room type can be used for elder who lives alone or an elderly couple. Senior Congregate Housing type can be used for four to five people. These two types have equal sunlight and ventilation conditions for each room, and are for an old man in relatively good health. Membership resort type is for the healthy senior who lives in the rural area or lives in the city who wants short-term residence. In case of a Nursing home type, the existing one-sided corridor was converted into a central corridor and each classroom is divided into four rooms. This type has advantage for nursing and management, on the other hand, the corridor is narrow and each room has differences for sunlight and ventilation.